EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CDN S1/2/3/4/5/8/9/15/25 for coupling and decoupling networks of shielded lines
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CDN S1/2/3/4/5/8/9/15/25 for coupling and decoupling networks of shielded lines
- Commodity ID: 1064668148977520640
- 品牌11: FRANKONIA
- 行业: 民用
- 描述: CDN-S type coupling and decoupling network is used for the test of shielded wire.
- 品牌: FRANKONIA
CDN-S type coupling and decoupling network is used for the test of shielded wire. Despite the wide variety of connectors, interfering signals are in all cases coupled to the cable shield via a 100Ω resistor. Directly coupled devices can also be used (without decoupling network).

Coupling and decoupling network CDN-S1 circuit diagram for shielded wires
-
Specific indicators:
model
C DN- S 1
CDN-S2
CDN-S4
CDN-S8
RF-IN
Frequency Range
150kHz-230MHz
power input
6W (continuous)
Decoupling parameters
(RF In-AE)>35dB(150kHz-80MHz)
>30dB(80MHz-230MHz)Insertion loss
(RF In-EUT)10dB±1dB(150kHz-80MHz)
10dB+3dB(80MHz-230MHz)Connector
BNC
UT/ YES
Input voltage
max AC150V
Input voltage
max DC200V
Current class
(AE-EUT)1.5A
Insertion loss
(AE-EUT)<1 dB(DC-10MHz)
<10 dB(10MHz -500MHz)Connector
BNC
XLR
5-pin XLR
8-pin Mini-DIN
physical dimension
width x height x length
160mmx84.5mmx240mm
model
CDN-S9
CDN-S15
CDN-S25
RF-IN
Frequency Range
150kHz-230MHz
power input
6W (continuous)
Decoupling parameters
(RF In-AE)>35dB(150kHz-80MHz)
>30dB(80MHz-230MHz)Insertion loss
(RF In-EUT)10dB±1dB(150kHz-80MHz)
10dB+3dB(80MHz-230MHz)Connector
BNC
UT/ YES
Input voltage
max AC150V
600V
(1000V VHV models)600V
Input voltage
max DC200V
1000V
(1700V VHV models)1000V
Current class
(AE-EUT)1.5A
Insertion loss
(AE-EUT)<1 dB(DC-10MHz)
<10 dB(10MHz -500MHz)Connector
9-pin Sub-D
15-pin Sub-D
25-pin Sub-D
physical dimension
width x height x length
160mmx84.5mmx240mm
model
USB-C
USB-P
HDMI
Firewire
USB-3.0
RJ45-S
RF-IN
Frequency Range
(10kHz)150kHz-230MHz
power input
6W (continuous)
Decoupling parameters
(RF In-AE)>50dB(150kHz-80MHz)
>25dB(80MHz-230MHz)>30dB(150kHz-230MHz)
>15dB(80MHz-230MHz)Insertion loss
(RF In-EUT)10dB±1dB(150kHz-80MHz)
10dB+3dB(80MHz-230MHz)Connector
BNC
UT/ YES
Input voltage
max AC100V
Input voltage
max DC150V
Current class
(AE-EUT)0.5A
0.9A
1.0A
Insertion loss
(AE-EUT)<1 dB(DC-10MHz)
<10 dB(10MHz -500MHz)<0.3 dB
(DC–10MHz)
<1dB
(10MHz–100MHz)
<3dB
(100MHz–500MHz)Connector
EUT:
USB-B
AE:
USB-AEUT:
USB-A
AE:
USB-BHDMI
19-polFirewire
6-polUSB-3.0
Shielded RJ45 jack
physical dimension
width x height x length
160mmx84.5mmx240mm
direct injection device
Frequency range (RF IN)
150kHz-230MHz
Common Mode Impedance (IN/OUT)
100Ω
Power input (RF IN)
6W (continuous)
connector output
Alligator clip, maximum clamping cable diameter: 30mm
Connector IN
BNC
Ordering Information:
CDN-S1, BNC,150kHz-300MHz
CDN-S1-10k, BNC,10kHz-230MHz
CDN-S1-75Ω, BNC, 150 kHz - 230 MHz
Calibration Adapter, CDN-S1
CDN-S2, XLR, 150 kHz - 230 MHz
CDN-S2-10k, XLR, 10 kHz - 230 MHz
Calibration Adapter, CDN-S2
CDN-S3-10k, XLR, 10 kHz - 230 MHz
Calibration Adapter, CDN-S3
CDN-S4, 5-pin XLR, 150 kHz - 230 MHz
Calibration Adapter, CDN-S4
CDN-S8, 8-pin Mini-DIN, 150 kHz - 230 MHz
Calibration Adapter, CDN-S8
CDN-S9, 9-pin Sub-D, 150 kHz - 230 MHz
CDN-S9-10k, 9-pin Sub-D, 10 kHz – 230 MHz
Calibration Adapter, CDN-S9
CDN-S15, 15-pin Sub-D, 150 kHz - 230 MHz
Calibration Adapter, CDN-S15
CDN-S25, 25-pin Sub-D, 150 kHz - 230 MHz
Calibration Adapter, CDN-S25
CDN-USB-C, EUT: USB-B, AE: USB-A, 150 kHz - 230 MHz
CDN-USB-C-10k, EUT: USB-B, AE: USB-A, 10 kHz - 230 MHz
Calibration Adapter, CDN-USB-C
CDN-USB-P, EUT: USB-A, AE: USB-B, 150 kHz - 230 MHz
CDN-USB-P-10k, EUT: USB-A, AE: USB-B, 10 kHz - 230 MHz
Calibration Adapter, CDN-USB-P, USB-3.0
CDN-USB-3.0, EUT: USB-A, AE: USB-A, 150 kHz - 230 MHz
CDN-RJ45-S, shielded network cable RJ45, 150 kHz - 230 MHz
CDN-RJ45-S-10k, shielded network cable RJ45, 10 kHz – 230 MHz
Calibration Adapter, CDN-RJ45-S
CDN-Firewire, 6 pole IEEE 1394 receptacle, 150 kHz - 230 MHz
Calibration Adapter, CDN-Firewire
CDN-HDMI, 19-pole HDMI 1.3 receptacle, 150 kHz - 230 MHz
Calibration Adapter, CDN-HDMI
Calibration adapter mounting bracket includes 50/150 Ohm adapter and 50 Ohm termination
Direct injection set including 100 Ohm, alligator clips, calibration adapter