EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
DC power input port voltage dip, short interruption and voltage variations test
1. Overview
IEC 61000-4-29 is applicable to immunity tests for voltage dips, short interruptions and voltage variations of electrical and electronic equipment supplied with DC power.
- voltage dip
A sudden drop in voltage at a certain point in an electrical system, returning to normal after a period of half a cycle or even a few seconds.
- short interruption voltage interruption
The power supply voltage suddenly disappears for a period of time, generally not more than one minute.
- voltage variation
The supply voltage goes above and below the rated voltage, the duration of the change can be longer or shorter relative to the period.
The test level of the voltage sag is expressed in %UT (the remaining voltage after the sag is the percentage of the reference voltage): 0%, 40%, 70%, 80%.
A short interruption generally refers to a complete interruption of the power supply for 250 cycles (50Hz) or 300 cycles (60Hz)
The voltage change generally refers to the situation where it is maintained for one cycle after a sudden change to 70%, and then returns to the reference voltage after 25/30 cycles.
2. Test method and test arrangement
2.1. Test method
When the test generator generates a short-time interruption, the following requirements shall be met:
--When running in "low impedance", it can absorb the inrush current from the load (if it happens)
--When running in "high impedance", it can block the reverse surge current of the load
-- In voltage sags and voltage changes, the generator should operate in a "low impedance" state
2.1.1 Characteristics of the test generator operating at low impedance:
--Peak surge current drive capability:
When U=24v, 50A
When U=48V, 100A
When U=110V, 220A
-- Impulse current polarity: positive polarity (flow to EUT), negative polarity (reverse from EUT)
2.1.2 Characteristics of test generator operating in high impedance state (short interruption)
During a short interruption, the impedance of the output terminal of the generator should be ≥100kΩ, and its impedance needs to be measured at a voltage level up to 3×U0 and in both polarities.
Examples of test generators and arrangements Figure A.1 and Figure A.2 show possible test block diagrams In Figure A.1, voltage dips, short interruptions and voltage changes are simulated by two DC power supplies with variable output voltages . The duration of the interruption can be preset. The voltage drop and rise can be simulated by alternately closing switch 1 and switch 2. These two switches must never be closed at the same time. When carrying out voltage drop and voltage change tests in the "low impedance" state, special precautions must be taken, for example: use capacitors to avoid "high impedance". Turn on two switches at the same time to realize power interruption, that is, in the "high impedance" test state, replace the current source 2 with a short circuit or low impedance, so that the test generator can absorb the reverse current from the load, and realize power interruption, that is, "low impedance" Impedance" test state test generators can include diodes, resistors and fuses as well as switches. In Figure A.2, the programmable power supply replaces the DC power supply and the switch. This test arrangement is also applicable to the ripple immunity test of the DC power supply (GB/T17626.17)
2.2. Test layout
3. System Configuration
serial number |
product |
illustrate |
brand |
3.1 |
Three Phase Multifunction AC/DC Power Supply, 30kVA, with Arbitrary Waveform Generator, Compliant with IEC 61000-4-13, -4-14, -4-17, -4-27, -4-28, -4-29 And MIL-STD-704 and aviation standard requirements; 3*520V AC (pp), +/-425V DC; controlled by netwave.control test software; power supply voltage 3*400V or 3*480V |
EM TEST/ Switzerland |
|
3.2 |
HAR-tab |
Test environment, including solid wood test table, insulation support, etc. |
Wisdom/China |
3.3 |
Control-tab |
computer |
Wisdom/China |