EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
High voltage transient conducted immunity (ISO 7637-4)
Introduction to testing
With the promotion and popularization of new energy vehicles, the safety of high-voltage components inside the vehicle has become one of the main guarantees for the safety of the vehicle itself. The ISO 7637-4 standard is applicable to the bench test of the conduction transient of the shielded high-voltage power cord with the electrical system voltage between 60VDC and 1500VDC. Suitable for all types of electrically independent drive road vehicles (battery electric vehicle (BEV), hybrid electric vehicle (HEV) or plug-in hybrid electric vehicle (PHEV)). There are mainly two test waveforms as follows:
Pulse A: Ringing generated by switching operation of high-voltage semiconductors
Pulse B: A sine wave generated by the rotation of the electric drive motor and the harmonics of the grid
System Connection Diagram - Pulse A
System Connection Diagram - Pulse B
typical configuration
Comply with ISO 7637-4 Pulse A waveform test system |
||
serial number |
product |
illustrate |
1 |
All-in-one susceptibility test system NSG 4070, 4 kHz~1 GHz RF generator, and power meter, power amplifier, with 80 W, 150 kHz~230 MHz, including remote control software (USB disk), USO 4013, SN: (USB to Serial/Optical Adapter with 20m Optical Cable), RS232 Cable, LAN Cable, Keyboard (English), Power Cable GB, CH, USA / JP, EU |
|
2 |
icd.control |
icd.control software license for one generator, CWS, NSG 4060, NSG 4070B-xx, NSG 4070C-xx |
3 |
HV-AN 150 |
5 μH artificial mains network, unshielded butterfly connector, used in automotive electronics, Airborne and MIL |
4 |
SET 4001 |
Susceptibility test kit according to standard ISO 7637-4, frequency range 1~10 MHz, maximum power 80W, including 2x HV-AN 150, 2x HV-AN 150-TC, 2x load 200 W, 2x T-connector, RF Cables with Type N connectors, BAL 4070 and BAL 4070-TC |
5 |
ATN 6150 |
Attenuator 6 dB, 150 W, 1 GHz, N(f)-N(f) |
6 |
ATN 20050 |
Attenuator 20 dB, 50 W, 1 GHz, N(f)-N(f) Attenuator 20 dB, 50 W, 1 GHz, N(f)-N(f) |
Comply with ISO 7637-4 Pulse B waveform test system |
||
serial number |
product |
illustrate |
1 |
Three-phase multifunction AC/DC power supply, 67 kVA, 3x690 VAC (pp), +/- 560 VDC per phase, with +/- 1120 VDC (HV-DC mode), 1000 VDC isolation voltage, including arbitrary waveforms Generators, including Opt-3 Recovery 67, Opt-3 DC-EVR and Opt-3 Parallel 67. Including net.control and software license net.industry (IEC 61000-4-13, -14, -17, -28 , etc.) ,net.automotive (LV 123, VW 80300, etc.). Optional software license for MIL&DO standard testing, input voltage 400 V. |
|
2 |
C-BOX |
Capacitor box for ripple testing, including one 10uF and one 100 uF capacitor, selectable by jumper, maximum 700VAC/1000VDC isolation voltage, 6mm lab connector; |
3 |
Audio power amplifier module and DDS signal source for Ford EMC-CS-2009 test, RI140/150, CI 210/250 and superposition DC-Rippel-Tests. 210/250. |
|
4 |
Coupling unit, audio transformer for coupling sine wave (10Hz - 500kHz) to DC line. Rated current: 300A Rated voltage: 1200V DC |
|
5 |
AUTO TAB |
Automotive electronics ISO 7637 test environment, complies with standard ISO 7637-2, ISO 7637-3 including test table (2.4mx1.2mx0.9m), ground plane (2.4mx1.2m), ground strap, insulating mat |
6 |
BY GPIB |
GPIB card and GPIB cable (including computer) |