EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
SAC-10/H 10 m semi-anechoic chamber - mixed absorbing material
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: SAC-10/H 10 m semi-anechoic chamber - mixed absorbing material
- Commodity ID: 1064663634874617856
- 品牌11: FRANKONIA
- 行业: 军品,民用,汽车电子和整车
- 描述: The 10-meter anechoic chamber is designed and manufactured completely according to customer requirements.
- 品牌: FRANKONIA
The 10-meter anechoic chamber is designed and manufactured completely according to customer requirements. In order to let customers have a preliminary understanding of the size and performance of SAC-10, we define the following four standard chamber templates, and their quiet zone diameters range from 2.0m to 6.0m. The planning of the anechoic chamber must be carried out as early as possible, for example, at the same time as the external building of the anechoic chamber, so that the interface between them can be determined in time, so as to avoid later modification. Typical interfaces include the following: various supply paths, space reserved for the turntable/hub on the concrete floor, movement tunnels for sliding doors, and possible joints between the shielded room and the building. Furthermore, possible interfaces and emergency control/alarm systems, such as fire alarm and fire suppression systems, must also be taken into account. But when using our completely non-combustible wedge absorbers (using thin-film technology, fire class A2), it is usually possible to forget about installing these systems.
-
main feature:
The economical and high-performance solution fully meets the test distance of 10m, and the quiet zone QZ can be Ø3m to Ø6m
Fully meet CISPR 16-1-4 EMI and ANSI C63.4 (ETSI upgrade version) standards
Fully complies with IEC/EN 61000-4-3 EMS standard
The absorbing material laid on the ground can be stored in a chamber for easy use
More than 90% of the chamber's own products, global factories adopt unified process and quality control
The chamber project is fully controlled in Germany, with rigorous craftsmanship and construction specifications
The consistency of the absorbing material is excellent, and the simulation results have real guiding significance for the design
Prefabricated modular ferrite mounting technology saves installation time and provides consistent workmanship
Unique nano-material absorbing material, replacing traditional carbon powder technology
The absorbing material has excellent performance and good stability, and there is no problem of aging and sagging. If the performance drops within 10 years, the absorbing material will be replaced free of charge.
The absorbing material is completely non-combustible, the only one in the world that meets the requirements of DIN4102 A2 fire protection level, and avoids the occurrence of fire incidents in chambers
The chamber meets the cleanliness requirements, ISO 14644-1 class 5, and the materials are non-toxic
The absorbing material is moisture-proof, and there is no requirement for the humidity of the use environment, and it can be directly maintained with a vacuum cleaner
The absorbing materials can be replaced with each other, and the maintenance cost is extremely low
The newly designed three-knife and three-reed screen door has better performance and convenient maintenance
turnkey solution
-
Specific indicators:
model
SAC-10-3/H
SAC-10-4/H
Dimensions mm (length x width x height)
18,380x12,830x8,550
19,280x13,280x8,550
Frequency Range
9KHz/30MHz-18GHz (40GH optional)
Test distance
3m&10m
Quiet zone QZ (3m distance)
Ø3m
Ø3m
Quiet zone QZ (5m distance)
Ø3m
Ø4m
Quiet zone QZ (10m distance)
Ø3m
Ø4m
Absorbing material laying
Walls and Ceilings
Hybrid absorbing material
floor
Equipped with movable absorbing materials that meet the requirements of IEC/EN 61000-4-3 radiated immunity test and the voltage standing wave ratio of the radiated emission test site greater than 1GHz
Radiated emission test
Fully compliant with CISPR 16-2-3 and CISPR 22 requirements
Radiated immunity test
Fully compliant with IEC/EN 61000-4-3 standard
NSA Maximum Deviation
±3.5dB(30MHz-1GHz)
VSWR
5.5dB(1GHz-18GHz)
Uniformity
1.5mx 1.5m (75% of the 16 measurement points meet 0dB/+6dB, 26/80MHz-18GHz)
Standard configuration
One access door, 1,238mm x 2,118mm
a sliding door
Twelve to sixteen honeycomb waveguide windows for ventilation
A 250V, 2x16A AC power filter
A 440V, 50/60Hz, 4 x 64A AC mains filter
Wall panels
Feedthrough components: N-type connector, BNC connector, fiber optic interface
Distribution installation
lighting device
reflective ground
Elevated floor
Absorbing material laying
1 turntable (load-bearing up to 80 tons, special turntable can be customized)
1 antenna tower
1 antenna tower and turntable controller
Optional
Three-phase power filter
Signal Line/Data Line Filter
Air Conditioning System
Antenna bracket
Audio and video surveillance system
Other equipment, accessories