-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CHC Plus/CHC Plus L 3 m method semi-anechoic Chamber - Compact Plus version
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CHC Plus/CHC Plus L 3 m method semi-anechoic Chamber - Compact Plus version
- Commodity ID: 1064657478026416128
- 品牌11: FRANKONIA
- 行业: 民用
- 描述: CHC Plus achieves a compact hybrid chamber with a quiet zone of ø1.2 m at a measurement distance of 3 m.
- 品牌: FRANKONIA
CHC Plus achieves a compact hybrid chamber with a quiet zone of ø1.2 m at a measurement distance of 3 m. The CHC Plus is an upgradeable solution that can be converted from a semi-anechoic chamber configuration with a ground plane to a fully anechoic chamber configuration with floor absorbers. CHC Plus is an optimal solution, whether it is EMI pre-compliance testing or full compliance testing of immunity at a distance of 3m. CHC Plus L is the extended version of CHC Plus.
-
main feature:
The traditional square design and high-performance solution fully meet the test distance of 3m, and the quiet zone QZ reaches 1.2m
Pre-compatible with CISPR 16-1-4 EMI and ANSI C63.4 (ETSI upgrade version) standards (height limit scan)
Fully complies with IEC/EN 61000-4-3 EMS standard
The absorbing material laid on the ground can be stored in a chamber for easy use
More than 90% of the chamber's own products, global factories adopt unified process and quality control
The chamber project is fully controlled in Germany, with rigorous craftsmanship and construction specifications
The consistency of the absorbing material is excellent, and the simulation results have real guiding significance for the design
Prefabricated modular ferrite mounting technology saves installation time and provides consistent workmanship
Unique nano-material absorbing material, replacing traditional carbon powder technology
The absorbing material has excellent performance and good stability, and there is no problem of aging and sagging. If the performance drops within 10 years, the absorbing material will be replaced free of charge.
The absorbing material is completely non-combustible, and it is the only absorbing material in the world that meets the requirements of DIN4102 A2 fire protection level, avoiding fire incidents in chambers that may be caused by heat generation
The chamber meets the cleanliness requirements, ISO 14644-1 class 5, and the materials are non-toxic
The absorbing material is moisture-proof, and there is no requirement for the humidity of the use environment, and it can be directly maintained with a vacuum cleaner
The absorbing materials can be replaced with each other, and the maintenance cost is extremely low
The newly designed three-knife and three-reed screen door has better performance and convenient maintenance
turnkey solution
-
Specific indicators:
model
CHC Plus
CHC Plus L
Dimensions (LxWxH)
7,355 x 3,755 x 3,300 mm
7,580x4,655x4,350mm
Frequency Range
9KHz/30MHz-18GHz (40GH optional)
EMI: (30MHz-1GHz) pre-compatible; (1GHz-18GHz) fully compatible
EMS: fully compatibleTest distance
3m
Quiet zone QZ (3m distance)
Ø1.2m
Ø1.2m
Absorbing material laying
long wall
F006 ferrite absorbing material + H450 composite absorbing material with a center position of 7.2㎡
short wall behind EUT
F006 ferrite absorbing material + H450 composite absorbing material with a center position of 9.9㎡
short wall behind the antenna
F006 ferrite absorbing material (measured with a horn antenna when greater than 1GHz)
ceiling
F006 ferrite absorbing material + H450 composite absorbing material with a central position of 5.76㎡
Floor (SAC)
7.2㎡ movable H450 type composite absorbing material
floor (FAC)
F006 ferrite absorbing material + H450 composite absorbing material with a center position of 7.2㎡
Radiated emission test
Pre-compatible with CISPR 16-1-4 EMI and ANSI C63.4 (ETSI upgrade version) standard
(height limit Scan)Radiated immunity test
Fully compliant with IEC/EN 61000-4-3 standard
Compliant with NSA Maximum Deviation
±3.5dB(30MHz-1GHz)
The maximum voltage standing wave ratio of the site
5.5dB(1GHz-18GHz)
uniform field size
1.5mx 1.5m (75% of the 16 measurement points meet 0dB/+6dB)
Standard configuration
One access door, 1,013mm x 2,043mm
Two honeycomb waveguide windows for ventilation
A 250V, 2x16A AC power filter
two wall panels
Feedthrough components: six N-type connectors, six BNC connectors, two fiber optic interfaces
Distribution installation
lighting device
Elevated floor
Absorbing material laying
Optional
Three-phase power filter
Signal Line/Data Line Filter
Air Conditioning System
Antenna bracket
Audio and video surveillance system
Turntable (load-bearing up to 2 tons, special turntable can be customized)
Totally non-combustible composite absorbing material
Chamber Performance Calibration
measuring equipment
Other accessories