EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Ultra-small compact Chambe-UCC
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Ultra-small compact Chambe-UCC
- Commodity ID: 1064701841821552640
- 品牌11: FRANKONIA
- 行业: 军品,民用,汽车电子和整车
- 描述: As an alternative to the GTEM cell, UCC can be used for pre-certification testing and research and development.
- 品牌: FRANKONIA
UCC, as an alternative product of GTEM cell, can be used in the pre-certification pre-test and scientific research and development fields. The walls and ceiling of the chamber are completely covered with ferrite, and 6㎡ of composite absorbing material is installed on the back wall near the EUT to ensure that the test frequency range of the chamber can range from 30MHz to 18GHz. The main advantages of ultra-compact chambers compared to GTEM chambers are that testers can walk in them, that test arrangements can have cables feeding peripherals, and that larger samples can be tested. UCC can perform radiated emission and radiated immunity pre-tests on equipment at a test distance of 1 meter in accordance with the requirements of the IEC/EN 61000-4-3 standard. In addition, it is also suitable for pre-testing automotive components according to DIN/ISO 11452-2 and EN 55025 (CISPR 25). If necessary, the UCC can also be used as a standard shielded room for conduction testing. Due to its small external dimensions, it can be placed in a normal-sized laboratory or office.
-
main feature:
More than 90% of the chamber's own products, global factories adopt unified process and quality control
Manufacturers who can truly lead the development of chamber technology continue to introduce new products
The chamber project is fully controlled in Germany, with rigorous craftsmanship and construction specifications
The consistency of the absorbing material is excellent, and the simulation results have real guiding significance for the design
Prefabricated modular ferrite mounting technology saves installation time and provides consistent workmanship
Unique nano-material absorbing material, replacing traditional carbon powder technology
The absorbing material has excellent performance and good stability, and there is no problem of aging and sagging. If the performance drops within 10 years, the absorbing material will be replaced free of charge.
The absorbing material is completely non-combustible, and it is the only absorbing material in the world that meets the requirements of DIN4102 A2 fire protection level, avoiding fire incidents in chambers that may be caused by heat generation
The chamber meets the cleanliness requirements, ISO 14644-1 class 5, and the materials are non-toxic
The absorbing material is moisture-proof, and there is no requirement for the humidity of the use environment, and it can be directly maintained with a vacuum cleaner
The absorbing materials can be replaced with each other, and the maintenance cost is extremely low
The newly designed three-knife and three-reed screen door has better performance and convenient maintenance
-
Technical Parameters:
Dimensions (length X width X height)
4,280mm x 3,080mm x 2,550mm
Frequency Range
30MHz ~ 18GHz ( optional up to 40GHz)
Test distance
1 meter
Absorbing material laying
Walls and Ceilings
F006 type ferrite absorbing material
Adjacent to the rear wall of the EUT
6m 2 HF300 type composite absorbing material
floor
2m2 ferrite absorbing material between EUT and antenna
Radiated emission test
G
Radiated immunity test
1 meter radiated immunity certification test per IEC/EN 61000-4-3
Field uniformity area dimensions according to IEC/EN 61000-4-3
0.5mx 0.5m
maximum deviation
Four measurement points 100% comply with 0dB/+6dB
Standard configuration:
One access door, 1,013 x 2,043mm
A honeycomb waveguide window for ventilation
A 250V, 2x16A AC power filter
a wall panel
Feedthrough components: four N-type connectors, four BNC connectors, one fiber optic interface
Distribution installation
lighting device
Elevated floor
Absorbing material laying
Optional:
Three-phase power filter
Signal and/or Data Line Filters
fan
Antenna bracket
Video and Audio Surveillance Systems
chamber Performance Calibration
measuring equipment
other additional equipment