EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
SAC-3/ FEC-3 Transformer 3-meter semi-/ fully convertible anechoic chamber
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: SAC-3/ FEC-3 Transformer 3-meter semi-/ fully convertible anechoic chamber
- Commodity ID: 1064666802870177792
- 品牌11: FRANKONIA
- 行业: 民用
- 描述: SAC-3/ FAC-3 Transformer is Frankonia's fully compatible EMC test solution, with a measurement distance of 3.0 meters, providing half-wave and full-wave anechoic chamber solutions.
- 品牌: FRANKONIA
SAC-3/ FAC-3 Transformer is Frankonia's fully compatible EMC test solution, with a measurement distance of 3.0 meters, providing half-wave and full-wave anechoic chamber solutions. This semi-anechoic SAC chamber configuration provides a quiet zone (QZ) of ø2,0 m and complies with CISPR 16-1-4 as well as ANSI C63.4. This fully anechoic chamber FAC configuration provides a quiet zone (QZ) of ø1,5 m and complies with CISPR 16-1-4 and IEC/EN 16-4-22. This SAC-3/FAC-3 anechoic chamber adopts the traditional square design scheme, which fully meets the requirements of EMI and EMS testing.
-
main feature:
The traditional square design and high-performance solutions fully meet the test distance of 3m, and the quiet zone QZ reaches Φ1.5m-Φ2m
It can be flexibly converted from a semi-anechoic chamber to a fully anechoic chamber, economical and practical
Fully meet CISPR 16-1-4 EMI and ANSI C63.4 (ETSI upgrade version) standards
Fully complies with IEC/EN 61000-4-3 EMS standard
The absorbing material laid on the ground can be stored in a chamber for easy use
Optimized RF shielding of the vaults thanks to steel construction
The consistency of the absorbing material is excellent, and the simulation results have real guiding significance for the design
Prefabricated modular ferrite mounting technology saves installation time and provides consistent workmanship
Unique nano-material absorbing material, replacing traditional carbon powder technology
The absorbing material has excellent performance and good stability, and there is no problem of aging and sagging. If the performance drops within 10 years, the absorbing material will be replaced free of charge.
The absorbing material is completely non-combustible, and it is the only absorbing material in the world that meets the requirements of DIN4102 A2 fire protection level, avoiding fire incidents in chambers that may be caused by heat generation
The chamber meets the cleanliness requirements, ISO 14644-1 class 5, and the materials are non-toxic
The absorbing material is moisture-proof, and there is no requirement for the humidity of the use environment, and it can be directly maintained with a vacuum cleaner
The absorbing materials can be replaced with each other, and the maintenance cost is extremely low
The newly designed three-knife and three-reed screen door has better performance and convenient maintenance
turnkey solution
-
Specific indicators:
model
SAC-3 / FAC-3 Transformer
Dimensions (LxWxH)
9,680x6,530x6,000mm
Frequency Range
9KHz/26MHz-18GHz (40GH optional)
Test distance
3m
Quiet zone QZ (3m distance) IEC 61000-4-22
Ø2m; height 1.5 m (SAC); Ø1.5m; height 1.5 m (FAC)
Quiet zone QZIEC 61000-4-22
Ø1.5m(30 MHz-1 GHz);Ø1.0m(1GHz-6 GHz)
Absorbing material laying
Walls and Ceilings
The interior is fully paved with F006 type ferrite absorbing materials, and
partially laid with H600 and H1000 type composite absorbing materialsfloor
9㎡ P600 removable wedge absorber is used for radiation immunity test;
when the frequency is >1GHz, 14.2㎡ P450 removable wedge absorber is used for radiation emission testRadiated emission test
Fully compliant with EN 55022 and CISPR 22 Class B (30MHz-1GHz);
fully compliant with CISPR 16-2-3 (1GHz-18GHz)Radiated immunity test
Fully compliant with IEC/EN 61000-4-3 standard
Conforms to CISPR16-1-4 NSA maximum deviation
±3.5dB(30MHz-1GHz)
CISPR16-1-4 site voltage standing wave ratio
5.5dB(1GHz-18GHz)
IEC 61000-4-22 Site VSWR
SdBc ≤ 1,8 dB
uniform field size
1.5mx 1.5m (75% of the 16 measurement points meet 0dB/+6dB)
Standard configuration
One access door, 1,238mm x 2,118mm
Four to six honeycomb waveguide windows for ventilation
A 250V, 2x16A AC power filter
two wall panels
Feedthrough components: six N-type connectors, six BNC connectors, two fiber optic interfaces
Distribution installation
lighting device
reflective ground
Elevated floor
Absorbing material laying
Turntable (load-bearing up to 5 tons, special turntable can be customized)
antenna tower
Antenna Tower and Turntable Controllers
Optional
Three-phase power filter
Signal Line/Data Line Filter
Air Conditioning System
Antenna bracket
Audio and video surveillance system