EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
VSS 500N12 voltage surge simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: VSS 500N12 voltage surge simulator
- Commodity ID: 1064641121461358592
- 品牌11: EMTEST
- 行业: 民用
- 描述: The voltage surge simulator VSS 500N12 is capable of generating high-energy pulses as required by IEC standards.
- 品牌: EM TEST
The voltage surge simulator VSS 500N12 is capable of generating the high energy pulses required by the IEC standard. The resulting voltage surge pulses are used to test the voltage withstand capability of components, sockets, plugs, cables and many other devices.
-
main feature:
Test voltage up to 12kV
Waveform 1.2/50us
Built-in source impedance
Security lock
warning light control
Voltage/Current Measurement
spark detection
Front panel manual operation
USB and GPIB interface
Standards compliant:
IN 60335-1
IEC 384-14
IEC 60060
IEC 60335-1
IEC 60664
IEC 60950-1
IEC 61180-1
IEC 61180-2
IEC 62477-1
advantage:
The VSS 500N12 Voltage Surge Simulator is specially designed for testing the withstand voltage of insulating materials, components, sockets, plugs, cables and many other devices. The way is to test the voltage withstand capability through a transient test pulse.
With built-in voltage and current meters and spark detection functions, detailed test results can be obtained to evaluate the quality of the device under test.
VSS 500N12 has safety protection measures to ensure safety when operating at high voltage levels. In addition, it comes with safety lock and warning light control functions. Users can also choose a test box for added protection from exposure to high voltages, or from exploding components or debris.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iso.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
-
Specific indicators:
Model overview
VSS 500N12
12 kV pulse generator, 1.2/50 us, according to IEC 60060, 500 ohm impedance, low power consumption.
VSS 500N12.1
12 kV pulse generator, 1.2/50 us, ref. 60335, 40 ohm impedance, power dissipation 18J.
VSS 500N12.6
12 kV pulse generator, 1.2/50 us, 50 ohm impedance, power consumption 18J.
VSS 500N12.7
12 kV pulse generator, 1.2/50 us, according to IEC 60950, IEC 60950-1, ITU-T K.44, 13 ohm + 25 ohm impedance, see data sheet for special pulse circuit.
Voltage surge simulator, pulse 1.2/50US
open circuit voltage
500V - 12,000V ± 3%
Front time
1.2 us ± 30%
Pulse half peak time
50 us ± 20%
short circuit current
Maximum 24A ± 10%
Internal resistance
500 ohm± 10%, optional 40ohm or 50ohm
polarity
positive, negative, alternating
counter
1 - 30,000 or unlimited
trigger
trigger method
Automatic, manual, external trigger
CRO trigger
Oscilloscope 5 V trigger signal
Synchronize
0° - 360°, resolution 1°
pulse repetition rate
Up to 1Hz (1s - 999s)
output
direct output
Via high voltage connector, Zi = 500 ohm or selected internal resistance (40ohm or 50ohm)
Measurement
CRO voltage monitoring
10Vp vs. 12,000V
CRO current monitoring
10Vp vs. 24 A
peak voltage
12,000 V, LCD display
peak current
24 Amps, LCD display
current limiter
Ri = 500 ohm, resolution 0.1 A
Ri = 40 ohm, resolution 1.0 Atest program
Quick Start
Instant start, simple and fast
user testing program
Change voltage after N pulses
Change polarity after N pulsesServe
service, setup, self-test
interface
serial interface
USB
parallel interface
IEEE 488, addresses 1 - 30
general data
size and weight
19" / 3 HU, about 15 kg
supply voltage
115 / 230 V +10 / -15%
fuse
2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)
environment
temperature
10 °C to 35 °C
Relative humidity
30 % to 75 %, non-condensing
atmospheric pressure
86 kPa - 106 kPa
option
High voltage contactor
A pair of gun-type high voltage contactors for safely applying high voltage pulses to the EUT.
iso.control
Remote control and report generation software including standard test procedures and reporting capabilities.