EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
VSS 500N10 voltage surge simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: VSS 500N10 voltage surge simulator
- Commodity ID: 1064640122067767296
- 品牌11: EMTEST
- 行业: 民用
- 描述: According to the safety test requirements, the insulation capacity between the accessible parts and the parts connected to them and the dangerous dangerous live parts should be able to withstand surge pulses caused by transients caused by events such as l
- 品牌: EM TEST
According to safety test requirements, the insulation capacity between accessible parts and parts connected to them and hazardous live parts should be able to withstand surge pulses generated by transients caused by events such as lightning strikes. The voltage surge simulator VSS 500N10 complies with IEC 60065 and UL 6500 standards for safety testing of audio, video and similar electronic devices and is capable of generating high voltage transients.
-
main feature:
Test voltage up to 10kV
Designed according to IEC 60065
Fully UL 6500 Compliant
Security lock
warning light control
Front panel manual operation
USB and GPIB interface
Standards compliant:
IN 60065
IN 60950-1
IEC 60065
IEC 60950-1
UL 6500
advantage:
VSS 500N10 - 10kV Voltage Surge Simulator for Safety Testing
VSS 500N10 Voltage surge simulator, specially designed for safety testing of audio, video and similar electronic devices. The components required to generate the pulses are specified in the standard. The VSS 500N10 has a special switch that avoids energy loss due to breakdown or insufficient insulation.
VSS 500N10 has safety protection measures to ensure safety when operating at high voltage levels. In addition, it comes with safety lock and warning light control functions.
With iec.control remote control and report generation software, fully automatic testing can be realized.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iso.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
-
Specific indicators:
Voltage surge simulator generating IEC 60065 standard pulses
open circuit voltage
500V - 10,000V ± 10%
Surge capacitance
1nF
Series resistance
1,000ohm
Parallel resistance
>15Mohm
polarity
just
counter
1 - 30,000 or unlimited
trigger
trigger method
Automatic, manual, external trigger
CRO trigger
Oscilloscope 5 V trigger signal
pulse repetition rate
Up to 1Hz (1s - 999s)
output
direct output
Via high voltage connector, Zi = 1000 ohm
test program
Quick Start
Parameters can be adjusted online, simple and fast
user testing program
Change the voltage after N pulses
Change the phase angle after N pulsesServe
service, setup, self-test
interface
serial interface
USB
parallel interface
IEEE 488, addresses 1 - 30
Safety
safety circuit
Control input (24 V DC)
Warning Light
floating output contact
general data
size and weight
19" / 3 HU, about 12 kg
supply voltage
115 / 230 V +10 / -15%
fuse
2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)
environment
temperature
10 °C to 35 °C
Relative humidity
30 % to 75 %, non-condensing
atmospheric pressure
86 kPa - 106 kPa