Wisdom

Product


EMC Testing Solution Provider


VCS 500N10T Surge and Communication Surge Simulator

Brand:

EM TEST

VCS 500N10T Surge and Communication Surge Simulator
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: VCS 500N10T Surge and Communication Surge Simulator
    • Commodity ID: 1064636857464803328
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: The occurrence of surge pulses is caused by lightning directly or indirectly hitting outdoor circuits.
    • 品牌: EM TEST

      Combined Wave Simulator

      Surge pulses are caused by lightning directly or indirectly hitting outdoor circuits. This will cause a transient high voltage or high current from an electrical current or electromagnetic field. In addition, switching transients from switching glitches and system faults are another source of surges. Due to the nature of this phenomenon, almost all electrical and electronic equipment is affected by surges, which further justifies the need for extensive surge testing. The surge voltage to be tested should be as large as several thousand volts, and the surge current should be several thousand amperes.

  • main feature:

      Surge voltage up to 10 kV

      Inrush current up to 5 kA

      Communication surge voltage up to 10 kV

      Communication surge current up to 666 A

      with voltage/current monitor

      Built-in single-phase 16 A coupling/decoupling network

      warning light control

      Security lock

      Standard Test Procedure

      USB and GPIB interface

    Standards compliant:

      EN 300386 V1.3.2

      EN 61000-4-5

      IN 61000-4-9

      IEC 60255-22-5

      IEC 61000-4-5

      IEC 61000-4-9

      IEC 61326

      IEC 61850-3

      ITU-T K.12

      ITU-T K.20

      ITU-T K.21

      ITU-T K.45

    advantage:

      VCS 500N10T - Small Surge/Communication Surge Simulator with Built-in Coupling/Decoupling Network

      The VCS 500N10T can perform combined surge tests and communication surge tests up to 10 kV. It also has a built-in single-phase coupling/decoupling network for single-phase AC power port and communication port testing. Equipped with an external coupling/decoupling network, surge combined wave testing can be performed on power lines rated at 100 A per phase or more. No matter whether the coupling/decoupling network is connected or not, by selecting the desired coupling method, the source impedance value and coupling capacitance value will be automatically set.

      VCS 500N10T has a failure detection function for monitoring the level of the equipment under test. Peak voltage and peak current can not only be displayed on the front panel, but also can be uploaded to the software and recorded in the test report. In addition, the VCS 500N10T includes safety features such as access control warning lights and safety interlocks.

      Pre-programmed standard test routines are easy to use. Through the quick start test program of VCS 500N10T, the user can adjust the test parameters online during the test, so as to evaluate the sensitivity threshold of a single device under test. This feature is most suitable for product development testing.

      Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.

    controlling software:

      Control and report generation software iec.control

      iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.

      iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.

    Accessory equipment:

      CNI 503 - Three-phase coupling/decoupling network for burst and surge testing

      EM TEST provides a series of fully automatic three-phase coupling/decoupling networks for burst and surge testing to expand the testing capabilities for three-phase equipment under test. The nominal current of the network can be up to 100 A.

      CNV 503 - Three-phase coupling/decoupling network for surge testing

      EM TEST provides a series of fully automatic three-phase coupling/decoupling networks for surge testing, which can expand the test capability for three-phase equipment under test, and the rated current of the network can reach up to 100 A.

      CNV 504N/508N - Signal/Data Line Coupling/Decoupling Networks for Surge Testing

      CNV 504N / 508N coupling/decoupling network can couple surge pulses to I/O lines, signal/data lines and communication lines, meeting the requirements of IEC 61000-4-5 Ed 3.0 standard.

      CNV 504S/508S - Coupling/Decoupling Networks for Communication Surge Tests

      CNV 504S / 508S coupling/decoupling network can couple communication surge pulses to communication lines, meeting the requirements of IEC 61000-4-5 Ed 3.0 standard.

    appendix:

      MS 100N - Magnetic field coil for power frequency and pulsed magnetic field testing

      MS 100N is a 1 m * 1 m magnetic field coil, which meets the requirements of IEC / EN61000-4-8 and IEC / EN 61000-4-9 standards. The coil moves easily, is height-adjustable, and swivels 360 degrees. When it is necessary to generate low-level power frequency magnetic field strength, the current transformer MC 2630 can be used together. For high-level field strength tests above 100 A/m, MC 26100 current transformers are required.

  • Specific indicators:

    surge simulator

    AC Mains Port Test, IEC 61000-4-5 Standard Pulse 1.2 / 50 US - 8 / 20 US

    open circuit voltage

    500 V - 10,000 V ± 10%

    Rise Time

    1.2 us ± 30%

    Pulse half peak time

    50 us ± 20%

    short circuit current

    250 A - 5,000 A

    Rise Time

    8 us ± 20%

    Pulse half peak time

    20 us ± 20%

    polarity

    positive, negative, alternating

    counter

    1 - 30,000 or unlimited

    Communication port test, IEC 61000-4-5 standard pulse 10 / 700 US - 5/320US waveform

    open circuit voltage

    500 V - 10,000 V ± 10%

    Rise Time

    10 us ± 30%

    Pulse half peak time

    700 us ± 20%

    short circuit current

    12.5A - 250A

    Rise Time

    5 us ± 20%

    Pulse half peak time

    320 us ± 20%

    Energy storage capacitor

    20 uF

    source impedance

    40ohm (15ohm from generator, 25ohm to communication line)

    polarity

    positive, negative, alternating

    counter

    1 - 30,000 or unlimited

    Communication test, ITU and ETS standard pulse 10 / 700 US waveform

    open circuit voltage

    500 V - 10,000 V ± 10%

    Rise Time

    10 us ± 30%

    Pulse half peak time

    700 us ± 20%

    Energy storage capacitor

    20 uF

    polarity

    positive, negative, alternating

    counter

    1 - 30,000 or unlimited

    trigger circuit

    trigger method

    Automatic, manual, external trigger

    CRO trigger

    Oscilloscope 5 V trigger signal

    Synchronize

    AC power port, 0° - 360°

    Pulse output

    direct output

    Output via high voltage connector:
    - Zi = 2 ohm: 1.2 / 50us -8 / 20us
    - Zi = 15 ohm: 10 / 700 us - 5 / 320 us

    Coupled to the power port as required by the following standards

     

    An external coupling and decoupling network is required

    IEC 61000-4-5

    Line-to-line coupling, 2ohm
    line-to-ground coupling, 12ohm

    IT-T

    Line-to-line coupling, 2ohm
    line-to-ground coupling, 2ohm

    Coupled to the communication port as required by the following standards

    IT-T

    2 wires: T1, T2, 25 ohm each
    4 wires: T1, T2, T3, T4, 25 ohm each

    FCC part 68

    2 wires: T1, T2, 25 ohm each

    IEC 61000-4-5

    4 wires: T1, T2, T3, T4, 25 ohm each

    Measurement

    CRO voltage monitoring

    10 Vp corresponds to 10,000 V

    CRO current monitoring

    10 Vp corresponds to 5,000 A

    peak voltage

    10,000 V, LCD display

    peak current

    5,000 Amps, LCD display

    test program

    Quick Start

    Instant start, simple and fast

    Standard Test Procedure

    Conforms to IEC 61000-4-5 standard, test level 1-4
    complies with ITU-T standard

    user testing program

    Change polarity after N pulses
    Change coupling after N pulses
    Change voltage after N pulses
    Change phase angle after N pulses

    Serve

    Service, Setup, Self-Test

    interface

    serial interface

    Optical link with 3 m long cable, USB Type A connector

    parallel interface

    IEEE 488, addresses 1 - 30

    Coupled network interface

    control external coupling network

    Safety

    safety circuit

    Control input (24 V DC)

    Warning Light

    floating output contact

    general data

    size and weight

    19" /12 HU, about 44 kg

    supply voltage

    115 / 230 V +10 / -15%

    fuse

    2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)

    Environmental requirements

    temperature

    10 °C -35 °C

    Relative humidity

    30 % - 75 %, non-condensing

    atmospheric pressure

    86 kPa  - 106 kPa

    appendix

    Power Line Coupling/Decoupling Networks

    CNI 503S16

    Three-phase coupling/decoupling network 3x440V/16A for EFT burst and surge testing

    CNI 503S18

    Three-phase coupling/decoupling network 3x440V/32A for EFT burst and surge testing

    Signal line/communication line coupling/decoupling network

    general data

    4-wire communication line coupling/decoupling network
    complies with IEC 61000-4-5 Ed.3 standard Fig.9

    CNV 504N3

    Coupling/decoupling network for 4-wire signal line testing up to 10 kV

    CNV 508N3

    Coupling/decoupling network for 8-wire signal line testing up to 10 kV

    Communication Line Coupling/Decoupling Network

    CNV 504T5

    4-wire unshielded symmetrical line (communication line) coupling and decoupling network
    according to IEC 61000-4-5 standard Ed 3.0 (fig. 10)

    CNV 508T5

    8-wire unshielded symmetrical line (communication line) coupling and decoupling network
    conforming to IEC 61000-4-5 standard Ed 3.0 (fig. 10)

    CNV 504S10

    Impedance network 4 x 25ohm, test voltage 10kV

    High-speed communication line coupling/decoupling

    CNI 508N1 Assembly

    Applied to shielded or unshielded wire

    CNI 508N1

    Coupling/decoupling networks for shielded high-speed communication lines

    CNI 508N1

    Coupling network of unshielded high-speed communication lines

    SPN 508N1

    Protection network for auxiliary equipment with unshielded wires

    option

    IMN 2

    Impedance matching adapter for connection between direct output port and 2 ohm source impedance

    MS 100N

    Pulse magnetic field test field coils according to IEC 61000-4-9
    up to 2,000 A/m

     

全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you