EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
PFS 200N Series Automotive Power Failure Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: PFS 200N Series Automotive Power Failure Simulator
- Commodity ID: 1064631605562855424
- 品牌11: EMTEST
- 行业: 汽车电子和整车
- 描述: PFS 200N-Automotive Power Failure Simulator for Voltage Sag and Short Interruption Testing
- 品牌: EM TEST
PFS 200N - Automotive Power Fault Simulator for Voltage Dip and Short Interruption Testing
The PFS 200N is capable of simulating voltage dips and dips (micro-interruptions) as required by standards - mainly those of car manufacturers. Some standards require very short voltage rise and fall times, less than 1 us, and test equipment with electronic switches.
-
main feature:
Standalone test equipment for voltage dips and short interruptions
Rise/fall time < 1 us
With electronic short circuit protection
Rated voltage 80 V DC
Front panel operation
Standard Test Procedure
USB and GPIB interface
Standards compliant:
BMW GS 95003-2
BMWGS 95024-2-1
Chrysler CS-11809 (2009)
Chrysler CS-11979
Chrysler PF-9326
Cummins 14269 (982022-026)
DaimlerChrysler DC-10615
DaimlerChrysler DC-10842
DaimlerChrysler PF-10541
Fiat 9.90110
Ford EMC-CS-2009.1
Ford ES-XW7T-1A278-AB
Ford ES-XW7T-1A278-AC
Ford WDR 00.00EA
Freightliner 49-00085
GMW 3172
Hyundai/Kia ES 95400-10, Rev. D
Hyundai/Kia ES 96100-02 (2006)
Hyundai ES 39110-00
ISO 21848:2005
ISO 16750-2
Iveco 16-2103 Rev.15 (2010)
Jaguar EMC-CS-2010JLR V1.1 (2011-01)
RECEIVE D001-94
Kia/Hyundai ES 95400-10
Mack Trucks 606GS15
Mazda MES PW 67600
MBN 10615
MBN LV 124-1
Mitsubishi ES-X82010
Nissan 28401 NDS 02
OEM LV 124
Porsche
PSA B21 7090
PSA B21 7110
Renault 36.00.808/--D
Renault 36.00.808/--E
Renault 36.00.808/--F
Renault 36.00.808/--G
Renault 36.00.808/--H
Renault 36.00.808/--J
Renault 36.00.808/--K
SAE J2628 (2007)
Father TST/TS/WI/257
Toyota TSC3500G
Toyota TSC3590G
Toyota TSC6203G
Toyota TSC7203G
Volvo EMC Requirements (1998)
Volvo EMC Requirements (2002)
Volvo STD 515-0003
VW 80000
advantage:
PFS 200N is a stand-alone test equipment with electronic switches that can control the rapid rise or fall of voltage within 1 us when simulating voltage sags and dips (micro-interruptions). Simulating a voltage sag requires two DC voltage sources, while simulating a voltage dip (micro-interruption) requires only one DC voltage source. The PFS 200N is capable of controlling an external DC voltage source via a DC analog signal. At the same time, it can be easily integrated into a complete test system.
The operation of PFS 200N can be done manually or controlled by software through USB or GPIB interface. The failure detection function enables the user to control the ongoing test sequence based on the status of the device under test. Pre-programmed standard test routines provide maximum user convenience. PFS 200N also has a quick start test program, which can adjust parameters online during the test, so as to evaluate the sensitivity level of a single device under test.
operate:
easy to operate
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iso.control
iso.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration.
iso.control complies with international/national standards and the requirements of most car manufacturers' standards, and the relevant information is always updated according to the changing situation of the standards. Its powerful reporting function can help users generate test reports that meet international requirements.
iso.control supports Windows 2000, Windows XP, Windows Vista and Windows 7 operating systems. Remote control is done via USB or GPIB interface. iso.control supports various types of GPIB cards from American National Instruments.
Accessory equipment:
RDS 200N - External controllable DC voltage source
Performing a voltage dip (micro-interruption) test requires a controllable DC source that can be used to generate any voltage value from the battery voltage to 0 V. The RDS 200N fully meets this requirement and can be controlled via the PFS 200N's DC analogue output signal.
The RDS 200N is normally connected to the PF 2 input port of the PFS 200N.
-
Specific indicators:
PFS 200N model
PFS 200N30
Power Failure Simulator, 80 V / 30 A
PFS 200N50
Power Failure Simulator, 80 V / 50 A
PFS 200N100
Power Failure Simulator, 80 V / 100 A
PFS 200N150
Power Failure Simulator, 80 V / 150 A
PFS 200N200
Power Failure Simulator, 80 V / 200 A
PFS 200N30 Technical Data
DUT power supply voltage
For channels PF 1 / PF 2 up to 80 V
DUT supply current
30 A max. for channels PF 1 / PF 2
switching time
< 1 us(rise/fall time)
peak current
70 A for 500 ms duration
Safety
Short circuit protection
PFS 200N50 Technical Data
DUT power supply voltage
For channels PF 1 / PF 2 up to 80 V
DUT supply current
50 A for channel PF 1 / PF 2
switching time
< 1 us(rise/fall time)
peak current
100 A for 500 ms duration
Safety
Short circuit protection
PFS 200N100 Technical Data
DUT power supply voltage
For channels PF 1 / PF 2 up to 80 V
DUT supply current
100 A for channel PF 1 / PF 2
switching time
< 1 us(rise/fall time)
peak current
150 A for 500 ms duration
Safety
Short circuit protection
PFS 200N150 Technical Data
DUT power supply voltage
For channels PF 1 / PF 2 up to 80 V
DUT supply current
150 A max. for channel PF 1 / PF 2
switching time
< 1 us(rise/fall time)
peak current
200 A for 500 ms duration
Safety
Short circuit protection
PFS 200N200 Technical Data
DUT power supply voltage
For channels PF 1 / PF 2 up to 80 V
DUT supply current
200 A max. for channel PF 1 / PF 2
switching time
< 1 us(rise/fall time)
peak current
More than 200A
Safety
Short circuit protection
trigger
automatic trigger
Automatic release pulse
manual trigger
Manual release of individual pulses
external trigger
An external trigger releases a single pulse
CRO trigger
Trigger on oscilloscope +15 V signal
repetition rate
100 ms - 999 s
Voltage dip duration td
1 us - 10 s
interface
serial interface
USB
parallel interface
IEEE 488, addresses 1 - 30
analog interface
Control external DC source (such as RDS 200N) by O - 10 V DC signal
test program
Quick start test program
Instant start, easy and fast
Chrysler
Voltage dips, voltage dips, mechanical switches
Ford
Drop Out High 、Drop Out Low
Drop Out Single 、Power DipRSA / Renault
Micro interrupt
service program
service, setup, self-test
test environment
temperature
10 °C to 40 °C
Relative humidity
10 % to 90 %, non-condensing
atmospheric pressure
86 kPa - 106 kPa
general data
size and weight
19" / 3 HU, approx. 15 kg
19" / 6 HU, approx. 18kg (PFS 200N150 and PFS 200N200)supply voltage
115 / 230 V +10 / -15%
fuse
2 x T 1 AT
option
iso.control