Wisdom

Product


EMC Testing Solution Provider


The PFM 200N100.1 Automotive Power failure simulator complies with OEM LV 124 and OEM LV 148 standards as well as automobile manufacturer standards

Brand:

EM TEST

The PFM 200N100.1 Automotive Power failure simulator complies with OEM LV 124 and OEM LV 148 standards as well as automobile manufacturer standards
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: The PFM 200N100.1 Automotive Power failure simulator complies with OEM LV 124 and OEM LV 148 standards as well as automobile manufacturer standards
    • Commodity ID: 1064630263951806464
    • 品牌11: EMTEST
    • 行业: 汽车电子和整车
    • 描述: PFM 200N100.1-Automotive Power Failure Simulator for LV 124/LV 148 Standard and Automotive Manufacturer Standard Micro-Interrupt Testing
    • 品牌: EM TEST

      PFM 200N100.1 - Automotive Power Fault Simulator for LV 124/LV 148 Standard and Auto Manufacturer Standard Micro-Outage Tests

      PFM 200N100.1 Automotive Power Fault Simulator meets the test requirements of LV 124 standard pulses E10, E13 and E14 and LV 148 standard pulse E48-09 of German car manufacturers. It also meets the GMW 3172 standard sec. 9.2.18 for micro-interrupt rise/fall times as low as 200 ns. The PFM 200N100.1 has a 100 mA - 100 A power line switch; an independent ground return switch; these switches can support surge currents up to hundreds of amperes.

      For signal and data lines, the PFM 200N100.1 offers a 16-channel switch with a rated current of 100 uA - 2 A per channel.

  • main feature:

      With power line switch (100 A) and signal line/data line switch (2 A)

      Meet LV 124/LV 148 standard pulse E10 and E13 test

      bidirectional current

      Independent ground return switch

      Rise/fall times less than 200 ns

      Built-in short circuit switch <100 mohm

      Rated voltage DC ±100 V

      Short circuit protection function

    Standards compliant:

      BMW GS 95003-2

      BMWGS 95024-2-1

      BMW GS 95026

      BMW QV 65013 (2010-06)

      Chrysler CS-11979

      Chrysler PF-9326

      Cummins 14269 (982022-026)

      DaimlerChrysler DC-10615

      DaimlerChrysler DC-10842

      Fiat 9.90110

      GMW 3172

      Hyundai/Kia ES 95400-10, Rev. D

      Hyundai ES 39110-00

      Iveco 16-2103 Rev.15 (2010)

      LV 123

      LV 148

      many other automotive standards

      MBN 10615

      MBN LV 124-1

      Nissan 28401 NDS 02

      OEM LV 124

      OEM LV 124 (2013-02)

      OEM LV 148

      PSA B21 7110

      Renault 36.00.808/--L

      Father TST/TS/WI/257

      Toyota TSC3500G

      Toyota TSC3590G

      Toyota TSC6203G

      Toyota TSC7203G

      Volvo STD 515-0003

      VW 80000

      VW 82148

    operate:

      easy to operate

      Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.

    controlling software:

      Control and report generation software iso.control

      iso.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration.

      iso.control complies with international/national standards and the requirements of most car manufacturers' standards, and the relevant information is always updated according to the changing situation of the standards. Its powerful reporting function can help users generate test reports that meet international requirements.

      iso.control supports Windows 2000, Windows XP, Windows Vista and Windows 7 operating systems. Remote control is done via USB or GPIB interface. iso.control supports various types of GPIB cards from American National Instruments.

  • Specific indicators:

    model

    PFM 200N100.1

    DUT current 100mA-100A

    PFM 200N200

    DUT current 100mA-200A

    power cord switch

    switch

    2 Line Switches
    - DC+ Power Line
    - DC- Ground Line

    DUT power supply voltage

    ± 100 VDC

    DUT supply current

    100mA - 100A at 25°C

    current direction

    two-way

    switching time

    < 200 ns (rise/fall time)

    repetition rate

    10 us - 1 h

    fall time

    1 us - 1 h

    peak current

    400 A for 200 ms
    1,350 A for 1 ms
    I > 1,350 A with automatic cut-off

    Safety

    Short circuit protection

    Signal line, data line switch

    aisle

    16 independently switchable lines

    DUT power supply voltage

    Up to ± 40 VDC

    DUT supply current

    100 uA - 2 A per channel at 25 °C

    current direction

    two-way

    switching time

    < 1 us (rise/fall time)

    repetition rate

    500 us - 1 h

    fall time

    1 us - 1 h

    bandwidth

    50 MHz / 3 dB

    peak current

    5 A for 200 ms

    Safety

    Short circuit protection

    connector

    PHOENIX, DFMC connector 1.5 mm2,
    Push-in-spring cage connector

    universal switch

    switch impedance

    Power line: < 50 mOhm
    Data line: < 500 mOhm

    built-in switch

    Short circuit switch (DC+ - DC-)
    impedance <100 mOhm

    built-in switch

    100 mOhm
    according to LV 124

    built-in switch

    Low

    built-in switch

    high

    trigger

    trigger outward

    Auto trigger event via front panel BNC plug
    Trigger via oscilloscope 15 V signal

    trigger inward  


    Trigger a single event Pull down via the front panel BNC plug

    interface

    bus interface

    Connect the control cable of AutoWave

    monitor output

    DUT output, differential, front panel BNC plug, ratio 1:20

    Protect

    DC input protection

    Maximum maximum voltage ± 100 V,
    with fixture > 100 VDC

    Data Entry Protection

    Maximum voltage ± 40 V,
    mating fixture > 40 VDC

    Overheating protection

    NTC measurements on each MOSFET switch

    overcurrent protection

    Electronically Protects Each MOSFET Switch

    current measurement

    Overload measurement at the output

    Bus systems for data lines

    bus system

    - Low speed bus 100 kbit
    - High speed bus 500 kbit
    - LIN bus, baud rate 19200
    - FlexRay 10 Mbit  

    general data

    size and weight

    19" / 3 HU, 448 mm x 536 mm x 154 mm
    Approx. 10.5 kg

    supply voltage

    100 V - 265 V AC, 50 / 60 Hz

    fuse

    2 x2 AT

    temperature

    10 °C to 35 °C  

    Relative humidity

    25 % - 75 %, non-condensing

    atmospheric pressure

    86 kPa  - 106 kPa

    option

    CA LV 124

    PFM 200N100.1 for calibration

    CA LV 124.1

    For PFM 200N200 calibration

    calibration

    LV124 Calibration

    Pulse Verification Calibration Components:
    Low Inductance
    Resistors Power Cords:
    CA LV124-P1R
    CA LV124-P100R
    Data Cords: 2-Wire Test
    CA LV124-D1R
    CA LV124-D1000R

    CA LV124-P1R

    Power line calibration
    1.0 Ohm ± 1%,
    maximum voltage: 12 V,
    maximum power: 30 W
    peak power: 150 W, 1 s

    CA LV124-P100R

    Power line calibration
    100.0 Ohm ± 1%,
    maximum voltage: 100 V,
    maximum power: 30 W
    peak power: 100 W, 1 s

    CA LV124-D1R

    Data line calibration
    1.0 Ohm ± 1%,
    maximum voltage: 2.0 V,
    maximum power: 1 W
    peak power: 4 W, 1 s

    CA LV124-D1000R

    Data line calibration
    1000 Ohm ± 1%,
    maximum voltage: 40.0 V,
    maximum power: 1 W
    peak power: 4 W, 1 s