EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
The PFM 200N100.1 Automotive Power failure simulator complies with OEM LV 124 and OEM LV 148 standards as well as automobile manufacturer standards
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: The PFM 200N100.1 Automotive Power failure simulator complies with OEM LV 124 and OEM LV 148 standards as well as automobile manufacturer standards
- Commodity ID: 1064630263951806464
- 品牌11: EMTEST
- 行业: 汽车电子和整车
- 描述: PFM 200N100.1-Automotive Power Failure Simulator for LV 124/LV 148 Standard and Automotive Manufacturer Standard Micro-Interrupt Testing
- 品牌: EM TEST
PFM 200N100.1 - Automotive Power Fault Simulator for LV 124/LV 148 Standard and Auto Manufacturer Standard Micro-Outage Tests
PFM 200N100.1 Automotive Power Fault Simulator meets the test requirements of LV 124 standard pulses E10, E13 and E14 and LV 148 standard pulse E48-09 of German car manufacturers. It also meets the GMW 3172 standard sec. 9.2.18 for micro-interrupt rise/fall times as low as 200 ns. The PFM 200N100.1 has a 100 mA - 100 A power line switch; an independent ground return switch; these switches can support surge currents up to hundreds of amperes.
For signal and data lines, the PFM 200N100.1 offers a 16-channel switch with a rated current of 100 uA - 2 A per channel.
-
main feature:
With power line switch (100 A) and signal line/data line switch (2 A)
Meet LV 124/LV 148 standard pulse E10 and E13 test
bidirectional current
Independent ground return switch
Rise/fall times less than 200 ns
Built-in short circuit switch <100 mohm
Rated voltage DC ±100 V
Short circuit protection function
Standards compliant:
BMW GS 95003-2
BMWGS 95024-2-1
BMW GS 95026
BMW QV 65013 (2010-06)
Chrysler CS-11979
Chrysler PF-9326
Cummins 14269 (982022-026)
DaimlerChrysler DC-10615
DaimlerChrysler DC-10842
Fiat 9.90110
GMW 3172
Hyundai/Kia ES 95400-10, Rev. D
Hyundai ES 39110-00
Iveco 16-2103 Rev.15 (2010)
LV 123
LV 148
many other automotive standards
MBN 10615
MBN LV 124-1
Nissan 28401 NDS 02
OEM LV 124
OEM LV 124 (2013-02)
OEM LV 148
PSA B21 7110
Renault 36.00.808/--L
Father TST/TS/WI/257
Toyota TSC3500G
Toyota TSC3590G
Toyota TSC6203G
Toyota TSC7203G
Volvo STD 515-0003
VW 80000
VW 82148
operate:
easy to operate
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iso.control
iso.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration.
iso.control complies with international/national standards and the requirements of most car manufacturers' standards, and the relevant information is always updated according to the changing situation of the standards. Its powerful reporting function can help users generate test reports that meet international requirements.
iso.control supports Windows 2000, Windows XP, Windows Vista and Windows 7 operating systems. Remote control is done via USB or GPIB interface. iso.control supports various types of GPIB cards from American National Instruments.
-
Specific indicators:
model
PFM 200N100.1
DUT current 100mA-100A
PFM 200N200
DUT current 100mA-200A
power cord switch
switch
2 Line Switches
- DC+ Power Line
- DC- Ground LineDUT power supply voltage
± 100 VDC
DUT supply current
100mA - 100A at 25°C
current direction
two-way
switching time
< 200 ns (rise/fall time)
repetition rate
10 us - 1 h
fall time
1 us - 1 h
peak current
400 A for 200 ms
1,350 A for 1 ms
I > 1,350 A with automatic cut-offSafety
Short circuit protection
Signal line, data line switch
aisle
16 independently switchable lines
DUT power supply voltage
Up to ± 40 VDC
DUT supply current
100 uA - 2 A per channel at 25 °C
current direction
two-way
switching time
< 1 us (rise/fall time)
repetition rate
500 us - 1 h
fall time
1 us - 1 h
bandwidth
50 MHz / 3 dB
peak current
5 A for 200 ms
Safety
Short circuit protection
connector
PHOENIX, DFMC connector 1.5 mm2,
Push-in-spring cage connectoruniversal switch
switch impedance
Power line: < 50 mOhm
Data line: < 500 mOhmbuilt-in switch
Short circuit switch (DC+ - DC-)
impedance <100 mOhmbuilt-in switch
100 mOhm
according to LV 124built-in switch
Low
built-in switch
high
trigger
trigger outward
Auto trigger event via front panel BNC plug
Trigger via oscilloscope 15 V signaltrigger inward
Trigger a single event Pull down via the front panel BNC pluginterface
bus interface
Connect the control cable of AutoWave
monitor output
DUT output, differential, front panel BNC plug, ratio 1:20
Protect
DC input protection
Maximum maximum voltage ± 100 V,
with fixture > 100 VDCData Entry Protection
Maximum voltage ± 40 V,
mating fixture > 40 VDCOverheating protection
NTC measurements on each MOSFET switch
overcurrent protection
Electronically Protects Each MOSFET Switch
current measurement
Overload measurement at the output
Bus systems for data lines
bus system
- Low speed bus 100 kbit
- High speed bus 500 kbit
- LIN bus, baud rate 19200
- FlexRay 10 Mbitgeneral data
size and weight
19" / 3 HU, 448 mm x 536 mm x 154 mm
Approx. 10.5 kgsupply voltage
100 V - 265 V AC, 50 / 60 Hz
fuse
2 x2 AT
temperature
10 °C to 35 °C
Relative humidity
25 % - 75 %, non-condensing
atmospheric pressure
86 kPa - 106 kPa
option
CA LV 124
PFM 200N100.1 for calibration
CA LV 124.1
For PFM 200N200 calibration
calibration
LV124 Calibration
Pulse Verification Calibration Components:
Low Inductance
Resistors Power Cords:
CA LV124-P1R
CA LV124-P100R
Data Cords: 2-Wire Test
CA LV124-D1R
CA LV124-D1000RCA LV124-P1R
Power line calibration
1.0 Ohm ± 1%,
maximum voltage: 12 V,
maximum power: 30 W
peak power: 150 W, 1 sCA LV124-P100R
Power line calibration
100.0 Ohm ± 1%,
maximum voltage: 100 V,
maximum power: 30 W
peak power: 100 W, 1 sCA LV124-D1R
Data line calibration
1.0 Ohm ± 1%,
maximum voltage: 2.0 V,
maximum power: 1 W
peak power: 4 W, 1 sCA LV124-D1000R
Data line calibration
1000 Ohm ± 1%,
maximum voltage: 40.0 V,
maximum power: 1 W
peak power: 4 W, 1 s