EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
AIF 503N Series Three-Phase Scintillation Impedance
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: AIF 503N Series Three-Phase Scintillation Impedance
- Commodity ID: 1064708844522459136
- 品牌11: EMTEST
- 描述: The AIF 503N series is a three-phase flicker impedance, and the whole series of products can cover the current range of 16 A - 75 A per phase.
- 品牌: EM TEST
The AIF 503N series is a three-phase flicker impedance, and the whole series of products can cover the range of each phase current from 16 A to 75 A. Able to provide two different impedance values, the reference impedance value according to EN / IEC 61000-3-3 and IEC 60725 standards and the test impedance value according to EN / IEC 61000-3-11 standard, the latter is used for testing Instruments and equipment connected to public low-voltage power supply systems with a supply current greater than or equal to 100 A.
-
Main features :
Impedance values comply with IEC/EN 61000-3-3 and IEC/EN 61000-3-11 standards
Unsaturated Air Coil Inductors
Line voltage 3 x 400 V
Up to 75 A per phase (model dependent)
Automatic overcurrent protection
LED indicators show test status
Remotely controlled by DPA 503N
Standards compliant:
IN 61000-3-11
EN 61000-3-3
IEC 60725
IEC 61000-3-11
IEC 61000-3-3
HE C 61000-3-2
advantage:
Three-phase flicker impedance, up to 75A
The AIF 503N series offers impedance values to meet the needs of both test applications (except AIF 503N16). It can not only provide the flicker impedance value that meets the requirements of the IEC 60725 standard flicker measurement and the IEC/EN 61000-3-3 standard, but also can provide the DUT with a rated current greater than 16A and connected to a low-voltage power supply network with a supply current greater than 100A. Impedance value required for flicker measurement.
The AIF 503N series uses unsaturated air coil inductors, and the inductance value is set manually.
The AIF 503N series is used in conjunction with the DPA 503N and is capable of single-phase and three-phase measurements. The software dpa.control enables complete remote control of the AIF 503N series. LED indicators on the front panel show the current application mode. The AIF 503N32/-N63/-N75 models are equipped with a cabinet with wheels, which can accommodate DPA 503N at the same time, which is very convenient to use.
-
Model overview
AIF 503N model
AIF 503N16
Three-phase 16A flicker impedance
AIF 503N32.1
Three-phase 32A flicker impedance
AIF 503N63.1
Three-phase 63A flicker impedance
AIF 503N75.1
Three-phase 75A flicker impedance
specific indicators
AIF 503N16
Phase current voltage range
16 A per phase
Three-phase output connector
CEE type connector, 16 A (3P, N, PE)
4 mm banana plug
Single-phase output connector
One output connector per phase (L1,L2,L3)
Adapter form depends on the country of use
Power supply
115 / 230 V,25W,50 / 60 Hz
size
19" / 3 HU
weight
about 20 kg
AIF 503N32.1
Phase current voltage range
32 A per phase
Three-phase output connector
CEE type connector, 32 A (3P, N, PE)
4 mm banana plug
Single-phase output connector
One output connector per phase (L1,L2,L3)
Adapter form depends on the country of use
single phase low current
Connect the L1 phase
Range: 100mA - 10A
Power supply
115 / 230 V,200W,50 / 60 Hz
size
19" / 25 HU with cabinet on removable casters
weight
100 kg
volume
1245 mm x 553 mm x 780 mm
AIF 503N63.1
Phase current voltage range
63 A per phase
Three-phase output connector
High current safety connector 80 A
Single-phase output connector
One output connector per phase (L1,L2,L3)
Adapter form depends on the country of use
single phase low current
Connect the L1 phase
Range: 100mA - 10A
Power supply
115 / 230 V,200W,50 / 60 Hz
size
19" / 38 HU, cabinet with removable casters
weight
230 kg
volume
1800 mm x 600 mm x 800 mm
AIF 503N75.1
Phase current voltage range
75 A per phase
Three-phase output connector
High current safety connector 80 A
Single-phase output connector
One output connector per phase (L1,L2,L3)
Adapter form depends on the country of use
single phase low current
Connect the L1 phase
Range: 100mA - 10A
Power supply
115 / 230 V,200W,50 / 60 Hz
size
19" / 38 HU, cabinet with removable casters
weight
250 kg
volume
1800 mm x 600 mm x 800 mm
General Data (All Models)
universal
configuration
Three-phase (3L, N, PE)
line voltage
3 x 400 V ± 10%
line frequency
47 Hz - 63 Hz
Bypass Harmonics Test
remote control switch
interface
15-pin SubD connector (remote control by DPA 503N)
indicator
LED indicators show operating status (bypass or current impedance in use)
impedance
Reference impedance, 50Hz
RA = 0.24 ohm,XA = 0.15 ohm
RN = 0.16 ohm,XN = 0.10 ohm
Test impedance, 50Hz
RA = 0.15 ohm,XA = 0.15 ohm
RN = 0.10 ohm,XN = 0.10 ohm
(not for AIF 503N16)
precision
Better than 3%
The inductor is an unsaturated air coil inductance, and the inductance value is set manually
Environmental requirements
temperature
0°C - 35°C
Relative humidity
80 %, non-condensing
atmospheric pressure
86 kPa - 106 kPa
cool down
Air Cooled, Active Cooling Control
option
Output connector for very low current VLCM Kit AIF 503N
Measurement output connector
Phase L1 with output connection for very low voltage
current range
5mA - 500mA
Accuracy
better than 1% of the measured value