EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
FFT3010_3030EMI measurement receiver
Brand:
AFJ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: FFT3010_3030EMI measurement receiver
- Commodity ID: 1064713185467715584
- 品牌11: AFJ
- 描述: Full FFT digital electromagnetic interference test receiver can measure 9KHz-300MHz conducted electromagnetic interference
- 品牌: AFJ
FFT 3010 & 3030 include preselector and preamplifier with advanced EMC testing software. PC integrated architecture of Windows 10 embedded operating system, FFT 3010 & 3030 EMI receiver can be controlled by advanced software to realize EMI test. Built-in preselectors provide excellent dynamic range and accurate EMI measurements. The frequency range covers 9 KHz-300 MHz. Remote control can also be performed from an external PC.
FFT3010 & 3030 built-in pre-selection amplifiers have excellent dynamic measurement range characteristics and provide extremely accurate electromagnetic compatibility testing. The measurement meets the requirements of international electromagnetic interference, European and product standards, and compares international standards through the measurement results The limit value and the corresponding detector measurement value are used to complete the test.
-
main feature:
FFT (Fast Fourier Transform) scan mode
Peak, quasi-peak, CISPR average
RMS (effective value) and CISPR RMS digital detector
Automatic insertion of attenuation during measurement sweeps avoids receiver saturation
Precise digital overload detector on analysis functions to avoid saturation effects
Correction of pulse weighting according to CISPR16-1-1 (from PRF 1Hz)
Quick test, fast detection of critical frequency (dwell time reduced to 1ms)
High sensitivity
Strong signal anti-jamming
low measurement uncertainty
high test speed
Test cable insertion loss, attenuator, amplifier loss, coupling network correction value, GTEM correction, antenna factor correction
Integrated Signal Generator
External reference frequency: 10MHz
Digital demodulation option with AM/FM/WBFM
-
Technical Parameters:
FFT3010
FFT3030
frequency
Frequency Range
9kHz-30MHz
9kHz-300MHz
frequency setting
1Hz
1Hz
internal reference frequency
Aging per Year
2 x 10-6
2 x 10-6
temperature drift
15 x 10-5 (+10°C to +40°C)
15 x 10-5 (+10 °C to +40 °C)
external reference frequency
10MHz
10MHz
Measuring Time (Manual Mode)
1ms to 5s
1ms to 5s
resolution
1 ms
1 ms
Measurement Time (Sweep Mode)
1ms to 5s
1ms to 5s
resolution
1 ms
1 ms
frequency resolution
Digital CISPR EMI Bandwidth
200Hz (-6dB bandwidth)
9kHz (-6dB bandwidth)
200Hz (-6dB bandwidth)
9kHz (-6dB bandwidth)
120kHz (-6dB bandwidth)
Preselection
tunable filter
9kHz to 150kHz
150kHz to 5MHz
5MHz to 10MHz10MHz to 15MHz
15MHz to 20MHz
20MHz to 30MHz9kHz to 150kHz
150kHz to 5MHz
5MHz to 10MHz10MHz to 15MHz
15MHz to 20MHz
20MHz to 30MHz30MHz to 60MHz
60MHz to 140MHz
140MHz to 300MHz
level
input level
DC voltage
50V (AC-coupled)
50V (AC-coupled)
CW RF power
+17dBm(InputAttenuation 0dB) +27dBm(Input Attenuation ≥10dB)
+17dBm(InputAttenuation 0dB) +27dBm(Input Attenuation ≥10dB)
Anti-jamming
mirror frequency
> 60dB
> 50dB
radio frequency shielding
3V/m (50Ωtermination)
3V/m (50Ωtermination)
noise floor
BW 200Hz BW 9kHz
BW 200Hz BW 9kHz BW120kHz
Noise Floor (termination 50Ω, input attenuation 0dB, preamplifier off)
the peak
< 10dBµV
< 20dBµV
quasi-peak
< 0dBuV
< 15dBuV
CISPR average
< 0dBuV
< 10dBuV
RMS
< 0dBuV
< 10dBuV
CISPR RMS
< 0dBuV
< 10dBuV
Termination 50Ω, input attenuation 0dB, preamplifier on
the peak
< 0dBµV
< 10dBµV
quasi-peak
< -10dBuV
< 5dBuV
CISPR average
< -10dBuV
< 0dBuV
RMS
< -10dBuV
< 0dBuV
CISPR RMS
< -10dBuV
< 0dBuV
FFT scan mode
Dual A/D Converter Resolution
16 bit
16 bit
Sampling Rate
122.8MHz _ _ _
variable
FFT span
141kHz ( full CISPR band A FFT)
5 MHz ( a total of 6 frequency bands covering all CISPR band B)
141kHz ( full CISPR band A FFT)
5 MHz ( a total of 6 frequency bands covering all CISPR band B)
5 MHz ( a total of 54 frequency bands covering the frequency band 30MHz-300MHz)
Simultaneous Parallel Detector
3009 (Band A)
1669 (Band B)
3009 (Band A)
1669 (Band B)
211 (30MHz-300MHz)
FFT frequency resolution
46,875 Hz (Band A)
3kHz (Band B)
46,875 Hz (Band A)
3kHz (Band B)
24kHz (30MHz-300MHz)
input and output
RF input
impedance
50 Ω
50 Ω
Connector
N female (RF 9kHz-30MHz )
N female (RF 9kHz-30MHz )
(RF 30MHz to 300MHz)
VSWR
< 2.0:1.0 (Input Attenuation 0dB)
< 1.2:1.0 (Input Attenuation ≥ 10dB)
< 2.0:1.0 (Input Attenuation 0dB)
< 1.2:1.0 (Input Attenuation ≥ 10dB)
input attenuator
0dB to 30dB in 10dB steps
0dB to 30dB in 10dB steps
Integrated Signal Generator
+50dBuV~+90dBuV
+50dBuV~+90dBuV
generally
interface
Ethernet 10/100 MB Remotable LAN (LXI Level 0 Protocol)
Ethernet 10/100 MB
Remotable LAN (LXI Level 0 Protocol)
power supply
230Vac ± 50-60Hz
230Vac ± 50-60Hz
power consumption
50VA
50VA
operating temperature
0° to 45°C
0° to 45°C
storage temperature
-20° to 70°C
-20° to 70°C
Dimensions (WxHxD)
450 x 135 x 436mm
450 x 135 x 436mm
weight
12 kg
12 kg