EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CCI capacitive coupling clamp and calibration assembly thereof
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CCI capacitive coupling clamp and calibration assembly thereof
- Commodity ID: 1064718367081517056
- 品牌11: EMTEST
- 描述: HFK is used to couple electrical fast transients/swarm pulses to I/O lines and meets the requirements of European and international standards for counter interference testing.
- 品牌: EM TEST
HFK is used to couple electrical fast transients/swarm pulses to I/O lines and meets the requirements of European and international standards for counter interference testing.
The application of electrical fast transients/pulse groups to a signal line generally cannot be achieved by discrete capacitive coupling without interfering with the signal flow. It is usually not possible to have direct access to the cables to be tested, such as coaxial or shielded cables. EM TEST's solution is to connect the interference simulator to both ends of the capacitive coupling clamp to achieve coupling through capacitive coupling clamp.
According to Ed 3.0 of IEC 61000-4-4 issued in 2012, the calibration of the capacitive coupling clamp is carried out by 50 ohm coaxial load using the standard calibration component ICC PVKIT 1.
-
Main features:
Complies with IEC 61000-4-4 standard Ed.3
Suitable for electrical fast transient/pulse group testing of signal and data lines
Effective coupling length is 1 m
Pulse group voltage 7 kV
Test cable diameter up to 40 mm
The capacitive coupling clamp calibration assembly complies with IEC 61000-4-4 Ed.3
Meet the standard:
IEC 61000-4-4
EN 61000-4-4
IEC 61000-4-18
EN 61000-4-18
CCI PVKIT 1 Calibration Settings:
Calibration of capacitive coupling pliers
IEC 61000-4-4 standard Ed 3.0 recommends that the capacitive coupling pliers be calibrated. EM TEST has developed and designed the CCI PVKIT 1 calibration module in accordance with the requirements of the standard.
The following facilities are required for calibration:
CCI PVKIT 1: Includes sensor board and support accessories
PVF 50:50 ohm load resistance
PVF AD 3:4 mm adapter for connecting sensor boards to SHF coaxial connectors for KW 50
Calibration Settings:
The sensor plate shall be placed in the capacitive coupling clamp so that the end of its connecting adapter is aligned with the edge of the coupling plate. The connection adapter PVF AD 3 is connected to a low impedance connection band and connected to the ground reference plane of the 50 ohm coaxial measuring terminal/attenuator. Connect the load resistor KW 50 to the AD-CA EFT adapter. The PVF 50 is positioned at the same height of 100 mm from the ground reference plane as the coupling clamp using the acrylic support attachment.
The distance between the sensor plate and the PVF 50 measuring terminal/attenuator should be less than 0.1 m.
This technical parameter table gives the setting diagram.

Coupling clamp calibration:
To calibrate the capacitive coupling plane, the open circuit voltage of the electric fast transient/pulse group generator (50 ohm output) is set to: 2,000 V
The resulting output voltage across PVF 50(50 ohm matching resistor) is 1,000 V
Measurement voltage Vm: 10 V
Voltage value measured by oscilloscope at 50 ohm input impedance: 5 V
The resulting attenuation value (theoretical) : 400:1

-
CCI Capacitive Coupling Clamp
highest voltage
7.0 kV
Coupling plate size
140 mm x 1000 mm
high
Ground - coupling plate, 100 mm
Connector
High voltage connector, coaxial
ground
4 mm banana plug
Equipment under test cable
Diameter up to 40 mm
weight
10.6 kg
common data
ambient temperature
10° C - 40° C
Relative humidity
85% maximum, no condensation
atmospheric pressure
86 kPa - 106 kPa
ICC PVKIT 1 Calibration Kit
Sensor board technical data
Description
Sensor board with 4mm connection plugSensor board with 4 mm connection plug
acrylic support
Bracket for measuring adapter PVF50 at a level of 100 mm for calibration of capacitive coupling clamps
PVF AD3
Adapter 4 mm to coaxial SHF connector
(connects load resistor to sensor board)PVF BKIT 1 Pulse Group Verification Kit
PVF 50
sensor board with 4mm connection plugCoaxial 50 Ohm Load Resistor for EFT/Burst Transient Verification
PVF 1000
Coaxial 1000 Ohm Load Resistor for EFT/Burst Transient Verification
PVF AD1
Adapter to match 4mm/6mm EUT output to PVF 50 load resistor, (connect load resistor to EUT output)