EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
UCS200N ultra-small car transient simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: UCS200N ultra-small car transient simulator
- Commodity ID: 1064720037454696448
- 品牌11: EMTEST
- 描述: Ultra-small car transient simulator that can simulate car transient pulses 1,2 and 3a/3b.
- 品牌: EM TEST
Ultra-compact automotive transient simulator for simulating automotive transient pulses 1, 2 and 3a/3b.
UCS 200N series automotive transient pulse ultra-small conducted anti-interference signal simulator integrates EFT/burst module, micropulse module and required coupling network into one device. The UCS 200N series of simulators meet international standards and the standards of many car manufacturers around the world. Depending on the model, the built-in coupling network can reach a maximum current of 200 A. The built-in coupling network can also be controlled by any one of the LD 200N series, VDS 200N series and PFS 200N series simulators. For non-standard testing, the micropulse generator can generate various waveform parameters through the FreeStyle free programming mode.
-
main feature:
Built-in electrical fast transient/burst generator module
Built-in micropulse generator module, in line with ISO 7637, JASO, SAE and NISSAN standards
Built-in 80 V coupling network with a maximum current of 200 A
Built-in battery switch
With overcurrent protection function
USB and GPIB-Bus interface
With emergency stop function
Test software supports Windows Vista and Windows 7 operating systems
-
Technical Parameters:
Model UCS 200N
UCS 200N50
Built-in coupling/decoupling network 80 V / 50 A, 100 A for 500 ms
UCS 200N100
Built-in coupling/decoupling network 80 V / 100 A, 150 A for 500 ms
UCS 200N150
Built-in coupling/decoupling network 80 V / 150 A
UCS 200N200
Built-in coupling/decoupling network 80 V / 200 A
enter
Power supply of the device under test +/-
DC voltage input from VDS 200N or other DC sources
Pulse 5, 7
Input from LD 200N
output
Power supply of the device under test +/-
Central DUT output port
Coaxial output port
Connection of capacitive coupling clamps compliant with ISO 7637-3:2007
EFT/Burst Module, Pulse 3A/3B
Compliant with ISO 7637-2 standard
Test voltage
25 V - 1,000 V ± 10%
Rise Time
5 ns ± 1.5 ns
Pulse duration
150 ns ± 45 ns
verify
Verified with 50 ohm and 1,000 ohm impedance according to ISO 7637-2:2011 standard AnnexC
source impedance
Zq = 50 ohm
polarity
Pulse 3b is positive, pulse 3a is negative
trigger circuit
trigger burst
Automatic, manual, external trigger
burst duration
T4 = 0.1 ms - 999.9 ms
repetition rate
T5 = 10 ms - 99,900 ms
Pulse frequency
f = 0.1 kHz - 200 kHz
test duration
T = 0:01 min - 999:59 min
T > 999:59 min --> infinitely long
output
direct output
Via 50 ohm coaxial connector (suitable for testing with capacitive coupling clamps)
Coupling method
Connect to the positive pole of the battery (for power supply line test)
CRO trigger
Oscilloscope 5 V trigger signal
test program
Quick start test program
Parameters can be adjusted online, easy to operate
Standard Test Procedure
ISO 7637-2:2011 Standard Classes 1 - 4
user testing program
Randomly output bursts; change voltage after T time; change frequency after T time
Micropulse module to generate pulses 1, 2A and 6
Compliant with ISO 7637-2:2011 standard
Test voltage
U = 20 V - 600 V ± 10% (peak voltage and polarity depend on the selected test standard)
repetition rate
0.2 s - 99.0 s
ISO pulse 1 (12 V power supply system)
Rise Time
1 us +0% / -50% (10% - 90%)
Pulse duration
2 ms ± 10% (10% - 10%)
Internal resistance
10 ohm ± 10%
ISO pulse 1 (24 V power supply system)
Rise Time
3 us +0% / -50% (10% - 90%)
Pulse duration
1 ms ± 10% (10% - 10%)
Internal resistance
50 ohm ± 10%
ISO pulse 2 (12 V / 24 V power supply system)
Rise Time
1 us +0% / -50% (10% - 90%)
Pulse duration
50 us ± 10% (10% - 10%)
Internal resistance
2 ohm ± 10%
ISO pulse 6 (12 V power supply system)
Rise Time
60 us +0% / -50% (10% - 90%)
Pulse duration
300 us ± 10% (10% - 10%)
Internal resistance
30 ohm ± 10%
Capable of covering the following standards according to ISO 7637-2
SAE J1113
DC 10614
GM 3097
Renault
BMW
FIAT
Volkswagen
Mitsubishi
PSA
Honda
Chrysler PF 9326
Ford ES-XW7T
Micropulse testing to automotive manufacturer standards
JASO D-001 Pulse A2
Test voltage
+110 V
capacitance
C = 4.7 uF
Pulse duration
2.5 us ± 30% time constant (36.8%)
Internal resistance R1
0.6 ohm ± 10%
Internal resistance R2
0.4 ohm ± 10%
polarity
just
JASO D-001 Pulse B2
Test voltage
-260 V
capacitance
C = 33 uF
Pulse duration
2.0 ms ± 20% time constant (36.8%)
Internal resistance R1
60 ohm ± 10%
Internal resistance R2
80 ohm ± 10%
polarity
burden
JASO D-001 Pulse D2
Test voltage
+170 V
capacitance
C = 2.2 uF
Pulse duration
2.5 us ± 30% time constant (36.8%)
Internal resistance R1
1.2 ohm ± 10%
Internal resistance R2
0.9 ohm ± 10%
polarity
just
NISSAN 28400 NDS 03 Pulse B2
Test voltage
-300 V ± 10%
capacitance
C = 33 uF
Internal resistance R1
100 ohm ± 10%
Internal resistance R2
75 ohm ± 10%
polarity
burden
NISSAN 28400 NDS 07 Pulse C8
Test voltage
±300 V ± 10%
capacitance
C = 1 uF
Internal resistance R1
500 ohm ± 10%
Internal resistance R2
450 ohm ± 10%
polarity
positive and negative
NISSAN 28400 NDS 07 Pulse C50
Test voltage
± 300 V ± 10%
capacitance
C = 33 uF
Internal resistance R1
30 ohm ± 10%
Internal resistance R2
200 ohm ± 10%
polarity
positive and negative
NISSAN 28400 NDS 07 Pulse C300
Test voltage
- 300 V ± 10%
capacitance
C = 33 uF
Internal resistance R1
100 ohm ± 10%
Internal resistance R2
75 ohm ± 10%
polarity
burden
SAE J1455 | Mutual Inductance Pulse
Rise Time
1 us ± 20% (10% - 90%)
Pulse duration
15 us ± 20% time constant (36.8%)
Internal resistance
50 ohm ± 10%
SAE J1455 | Self-Induction Pulse
Rise Time
1 us ± 20% (10 - 90%)
Pulse duration
1,000 us ± 20% time constant (36.8%)
Internal resistance
20 ohm ± 10%
Pulse programming mode
Rise Time
1 us - 10 us , step size 1 us
Pulse duration
50 us - 10,000 us
Internal resistance
2 ohm - 1,000 ohm in steps of 5 ohm;
200 ohm,400 ohm,450 ohm
general data
size and weight
UCS 200N50
19" / 3 HU , about 20 kg
UCS 200N100
19" / 6 HU , about 30 kg
UCS 200N150
19" / 9 HU , about 35 kg
UCS 200N200
19" / 9HU , about 35 kg
supply voltage
115 / 230 V +10 / -15%
fuse
2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)
interface
serial interface
USB
parallel interface
IEEE 488 , addresses 1 - 30
Coupled network interface
Used to control the built-in coupling network and battery switch
environment
temperature
10 °C to 35 °C
Relative humidity
30 % to 75 % non-condensing
atmospheric pressure
86 kPa - 106 kPa
option
ACC
capacitive coupling clamp
KW 50
100 : 1 voltage divider, 50 ohm
KW 1000
500 : 1 voltage divider, 1,000 ohm
CA EFT kit
Electrical Fast Transient/Burst Calibration Components
A6dB
6 dB attenuator, 50 ohms
CA ISO
Load Resistors for Micropulse and Load Dump Pulse Calibration
iso.control
Test control software, built-in standard library, with test report generation and data conversion functions