EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
VDS 200Q Series Four-Quadrant Voltage Sag Simulator-Battery Powered Simulation and DC Voltage Source
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: VDS 200Q Series Four-Quadrant Voltage Sag Simulator-Battery Powered Simulation and DC Voltage Source
- Commodity ID: 1064720353105432576
- 品牌11: EMTEST
- 描述: The VDS 200Q series is used to simulate a variety of battery-powered waveforms that meet international standards and many automobile manufacturers' standards. Among them, the automobile manufacturers' standards have become an important part of the VDS 200
- 品牌: EM TEST
VDS 200Q - Four Quadrant Battery Powered Simulator and DC Voltage Source.
VDS 200Q series is used to simulate a variety of battery power supply waveforms that meet international standards and the standards of many automobile manufacturers. Among them, the standards of automobile manufacturers have become an important part of the coverage of VDS 200Q series because of the complexity of the test requirements.
In addition, the VDS 200Q series can also be used as a powerful DC voltage source to power the device under test in the automotive transient pulse test. The VDS 200Q series meets all three supply voltage types of 42 V, 24 V and 12 V. Depending on the model and test application, the test current is up to 100 A.
-
main feature:
Maximum test voltage up to 60 V
Bipolar Amplifier Module
Four-quadrant operation
low output impedance
Powerful DC voltage source
Comply with ISO 7637-2 / ISO 16750-2 standard pulse 4 and pulse 2b test requirements
The input interface can be connected to an external signal generator to generate complex waveforms
Test software supports Windows 7 operating system
USB and GPIB interface
-
Technical Parameters:
VDS 200Q10
The output voltage
-60 V - +60 V
Output current
0 A - 10 A ,contact
Bandwidth (-3dB)
DC - 180 kHz full-band signal
supply voltage
Single phase 100 / 120 / 230 V ± 10% L, N, PE
size
19"/6 HU
weight
about 37kg
VDS 200Q25.1
The output voltage
-20 V - +77 V
Output current
0 A - 25 A, contact
peak current
75 A for a duration of up to 200 ms
Bandwidth (-3dB)
DC - 150 kHz full band signal
Extended parameters
-20 V - +77 V ( max. 20 A)
150 - 250 kHz ( up to 40 Vpp)
supply voltage
Single phase 100 / 120 / 230 V ± 10% L, N, PE
size
19"/25 HU*)
weight
about 230 kg
VDS 200Q50.1
Built-in coupling/decoupling network 80 V / 150 A
The output voltage
-20 V - +77 V
Output current
0 A - 50 A, contact
peak current
150 A for a duration of up to 200 ms
Bandwidth (-3dB)
DC - 150 kHz full band signal
Extended parameters
-20 V - +77 V ( max. 20 A)
150 - 250 kHz ( up to 40 Vpp)
supply voltage
Three-phase 200/400 V ±10% L1, L2, L3, PE
size
19"/25 HU*)
weight
about 275 kg
VDS 200Q100.1
150 ns ± 45 ns
The output voltage
-20 V - +77 V
Output current
0 A - 100 A, connect
peak current
300 A for a duration of up to 200 ms
Bandwidth (-3dB)
DC - 150 kHz full band signal
Extended parameters
-20 V - +77 V ( Max. 80 A)
150 - 250 kHz ( up to 40 Vpp)
supply voltage
Three-phase 200/400 V ±10% L1, L2, L3, PE
size
19"/38 HU**)
weight
about 450 kg
VDS 200Q150.2
The output voltage
-20 V - +77 V
Output current
0 A - 150 A, connected
peak current
450 A for a duration of up to 200 ms
Bandwidth (-3dB)
DC - 150 kHz full band signal
Extended parameters
-20 V - +77 V ( Max. 120 A)
150 - 250 kHz ( up to 40 Vpp)
supply voltage
Three-phase 200/400 V ±10% L1, L2, L3, PE
size
2 x 19"/34 HU**)
weight
about 650 kg
VDS 200Q200.2
The output voltage
-20 V - +80 V
Output current
0 A - 200 A, connect
peak current
600 A for a duration of up to 200 ms
Bandwidth (-3dB)
DC - 150 kHz full band signal
Extended parameters
-20 V - +80 V ( Max. 120 A)
150 - 250 kHz ( up to 40 Vpp)
supply voltage
Three-phase 200/400 V ±10% L1, L2, L3, PE
size
2 x 19"/34 HU**)
weight
about 900 kg
**) Equipped with a cabinet, and the cabinet space can also accommodate AutoWave and NR-RAC AutoWave
General Data (All Models)
General technical data
source impedance
Zi = < 10 mohm
operate
Four-quadrant, bipolar operation
current limiter
(not applicable to VDS 200Q10) 3x Imax: Before the current limiter starts, the inrush current is allowed to reach three times the rated current for 200 ms
compensate
STD: DC - 40 kHz HF: DC - >=150 kHz CAP: DC - 3kHz
recover
>90% , recovery time < 25 us
output rise time
typ. <10 us, <3 us ( high frequency)
voltage fluctuation
Ur <10 mVp-p , minimum frequency 400 Hz
control
input analog signal
cool down
Air-cooled, temperature controllable
Protect
Magnetic circuit breaker protection (depending on the specific model of VDS 200Q)
trigger
automatic trigger
Automatic release pulse
manual trigger
Manual release of individual pulses
external trigger
An external trigger releases a single pulse
output
Power supply of the device under test +/-
Safety lab connector or high current connector
external trigger
5 - 15 V TTL signal, BNC connector
CRO trigger
Oscilloscope 5 V TTL signal
interface
serial interface
USB , Ethernet interface (for optional AutoWave), IEEE 488, address 1 - 30
remote control
External signal generator can be connected (10 kohm)
-10 V - +10 V / 0 - 150 kHz ( 180 kHz for VDS 200Q10 )
Arbitrary Waveform Test Procedure
DC source
Depends on VDS 200Q specific model
Function
Sine wave sweep pulse, sine wave ramp pulse, limiting load dump pulse, quick start pulse, external control pulse, GM9105P pulse 4, falling and overshooting pulse
Standard Test Procedure
ISO 7637 Pulse 2b and Pulse 4, ISO 16750-2
service program
service, setup, self-test
test environment
temperature
10 °C to 40 °C
Relative humidity
10 % to 90 % non-condensing
atmospheric pressure
86 kPa - 106 kPa
option
AutoWave
2- channel or 4-channel vehicle power supply system arbitrary waveform analog recorder to meet more complex testing requirements
PFM 200N100.1
Power failure simulator according to LV 124: E-10 and E-13, LV 148: E48-09. Controlled by AutoWave via bus interface.
PFM 200N200
200A PowerFail simulator for test requirements as per LV 124: E-10 and E-13 and LV 148: E48-09. Controlled by AutoWave via Framebus interface.
iso.control
Test control software, built-in standard library, with test report generation and data conversion functions