EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CISPR15 analog lamp assembly and lampshade
Brand:
SCHWARZBECK
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CISPR15 analog lamp assembly and lampshade
- Commodity ID: 1064721911582969856
- 品牌11: SCHWARZBECK
- 描述: Mainly used to measure the insertion loss of the ballast.
- 品牌: SCHWARZBECK
It is mainly used to measure the insertion loss of the ballast. Schwarzbeck can provide all kinds of simulation lamps required by CISPR15, EN 55015 and GB17743 standards.
-
main feature:
It is mainly used to measure the insertion loss of the ballast. Schwarzbeck can provide all kinds of simulation lamps required by CISPR15, EN 55015 and GB17743 standards.
-
Single ended double tube analog lamp with socket G23
LN G23
Socket LN G23 according to Fig. 4 e CISPR 15
Socket length 47 mm
The tube set corresponds to the required series of RS G23 / xxx
RS G23 / 85
Lamp specification - LN G23
Maximum lamp length 85 mm
Tube length 38 mm
Tube diameter 13 mm
5W
RS G23 / 115
Lamp specification - LN G23
Maximum lamp length 115 mm
Tube length 68 mm
Tube diameter 13 mm
7W
RS G23 / 145
Lamp specification - LN G23
Maximum lamp length 145 mm
Tube length 98 mm
Tube diameter 13 mm
9W
RS G23 / 215
Lamp specification - LN G23
Maximum lamp length 215 mm
Tube length 168 mm
Tube diameter 13 mm
11W
Single-ended four-tube analog lamp with socket G24
LN G24
Socket LN G24 according to Fig. 4 f CISPR 15
Socket length 45 mm
The tube set corresponds to the required series of RS G24 / xxx
RS G24 / 95
Lamp specification - LN G24
Maximum lamp length 95 mm
Tube length 50 mm
Tube diameter 13 mm
10W
RS G24 / 130
Lamp specification - LN G24
Maximum lamp length 130 mm
Tube length 85 mm
Tube diameter 13 mm
13W
RS G24 / 150
Lamp specification - LN G24
Maximum lamp length 150 mm
Tube length 105 mm
Tube diameter 13 mm
18W
RS G24 / 170
Lamp specification - LN G24
Maximum lamp length 170 mm
Tube length 125 mm
Tube diameter 13 mm
26W
Single-ended double-tube analog lamp with socket 2G11
LN 2G11
Socket LN 2G11 according to Fig. 4 d CISPR 15
Socket length 67 mm
Tube set corresponding to RS 2G11 / xxx required series
RS 2G11 / 225
Lamp specification - LN 2G11
Maximum lamp length 225 mm
Tube length 158 mm
Tube diameter 15 mm
18W
RS 2G11 / 320
Lamp specification - LN 2G11
Maximum lamp length 320 mm
Tube length 253 mm
Tube diameter 15 mm
24W
RS 2G11 / 415
Lamp specification - LN 2G11
Maximum lamp length 415 mm
Tube length 348 mm
Tube diameter 15 mm
36W
RS 2G11 / 535
Lamp specification - LN 2G11
Maximum lamp length 535 mm
Tube length 468 mm
Tube diameter 15 mm
55W
15mm diameter linear analog lamp with socket G5
LN G5
A pair of sockets LN G5 according to Figure 4 c CISPR 15
Single socket length 20 mm
The tube set corresponds to the required series of RS G5 / xxx
RS G5 / 136
Lamp specification - LN G5
Maximum lamp length 136 mm
Tube length 96 mm
Tube diameter 15 mm
4W
RS G5 / 212
Lamp specification - LN G5
Maximum lamp length 212 mm
Tube length 172mm
Tube diameter 15 mm
6W
RS G5 / 288
Lamp specification - LN G5
Maximum lamp length 288 mm
Tube length 248mm
Tube diameter 15 mm
8W
RS G5 / 517
Lamp specification - LN G5
Maximum lamp length 517 mm
Tube length 477mm
Tube diameter 15 mm
13W
RS G5 / 549
Lamp specification - LN G5
Maximum lamp length 549 mm
Tube length 509mm
Tube diameter 15 mm
14W
RS G5 / 849
Lamp specification - LN G5
Maximum lamp length 849 mm
Tube length 809 mm
Tube diameter 15 mm
21 W
RS G5 / 1449
Lamp specification - LN G5
Lamp maximum length 1449 mm
Tube length 1409 mm
Tube diameter 15 mm
35W
20mm diameter linear analog lamp with socket G13/25
LN G13 / 25
A pair of sockets LN G13 according to Figure 4 a CISPR15
Single socket length 75 mm
Tube set corresponding to RS G13 / 25 / xxx required series
RS G13 / 25 / 438
Lamp Size - LN G13/25
Maximum lamp length 438 mm
Tube length 288 mm
Tube diameter 20 mm
15W
RS G13 / 25 / 590
Lamp Size - LN G13/25
Maximum lamp length 590 mm
Tube length 440mm
Tube diameter 20 mm
18W
RS G13 / 25 / 720
Lamp Size - LN G13/25
Maximum lamp length 720 mm
Tube length 570 mm
Tube diameter 20 mm
16W
RS G13 / 25 / 895
Lamp Size - LN G13/25
Maximum lamp length 895 mm
Tube length 745 mm
Tube diameter 20 mm
30W
RS G13 / 25 / 970
Lamp Size - LN G13/25
Maximum lamp length 970 mm
Tube length 820 mm
Tube diameter 20 mm
36W
RS G13 / 25 / 1047
Lamp Size - LN G13/25
Lamp maximum length 1047 mm
Tube length 897mm
Tube diameter 20 mm
38W
RS G13 / 25 / 1200
Lamp Size - LN G13/25
Maximum lamp length 1200 mm
Tube length 1050 mm
Tube diameter 20 mm
36W
RS G13 / 25 / 1500
Lamp Size - LN G13/25
Lamp maximum length 1500 mm
Tube length 1350mm
Tube diameter 20 mm
58W
28mm diameter linear analog lamp with socket G13/38
LN G13 / 38
A pair of sockets LN G13 according to Figure 4 a CISPR15
Single socket length 75 mm
Tube set corresponding to RS G13 / 38 / xxx required series
RS G13 / 38 / 590
Lamp Size - LN G13/38
Maximum lamp length 590 mm
Tube length 440mm
Tube diameter 28 mm
20W
RS G13 / 38 / 970
Lamp Size - LN G13/38
Maximum lamp length 970 mm
Tube length 820 mm
Tube diameter 28 mm
25W
RS G13 / 38 / 1200
Lamp Size - LN G13/38
Maximum lamp length 1200 mm
Tube length 1050 mm
Tube diameter 28 mm
115W
RS G13 / 38 / 1500
Lamp Size - LN G13/38
Lamp maximum length 1500 mm
Tube length 1350mm
Tube diameter 28 mm
140W
RS G13 / 38 / 1800
Lamp Size - LN G13/38
Maximum lamp length 1800 mm
Tube length 1650mm
Tube diameter 28 mm
160W
RS G13 / 38 / 2400
Lamp Size - LN G13/38
Maximum lamp length 2400 mm
Tube length 2250 mm
Tube diameter 28 mm
125W
Single-ended double-tube analog lamp with socket 2G7
LN 2G7
Socket LN 2G7
Socket length 47 mm
Tube set corresponding to RS 2G7 / xxx required series
RS 2G7 / 85
Lamp Specifications - LN 2G7
Maximum lamp length 85 mm
Tube length 38 mm
Tube diameter 13 mm
5W
RS 2G7 / 115
Lamp Specifications - LN 2G7
Maximum lamp length 115 mm
Tube length 68 mm
Tube diameter 13 mm
7W
RS 2G7 / 145
Lamp Specifications - LN 2G7
Maximum lamp length 145 mm
Tube length 98 mm
Tube diameter 13 mm
9W
RS 2G7 / 215
Lamp Specifications - LN 2G7
Maximum lamp length 215 mm
Tube length 168 mm
Tube diameter 13 mm
11W
Single-ended U-tube analog lamp with socket 2G13
LN 2G13
Socket LN 2G13
Socket length 75 mm
Tube set corresponding to RS 2G13 / xxx required series
RS 2G13 / 310
Lamp specification - LN 2G13
Maximum lamp length 310 mm
Tube length 235 mm
Tube diameter 20 mm
20W
RS 2G13 / 607
Lamp specification - LN 2G13
Maximum lamp length 607 mm
Tube length 532 mm
Tube diameter 20 mm
40W
RS 2G13 / 765
Lamp specification - LN 2G13
Maximum lamp length 765 mm
Tube length 690mm
Tube diameter 20 mm
65W
Ring Simulation Light
LN G10q / 28 / 216
Full ring mock-up lights according to Figure 4b CISPR 15
The maximum diameter of the lamp is 216 mm
Tube diameter 20 mm
22W
LN G10q / 32 / 311
Full ring simulated lamp according to Figure 4b CISPR 15
The maximum diameter of the lamp is 311 mm
Tube diameter 28 mm
32W
LN G10q / 32 / 413
Full ring simulated lamp according to Figure 4b CISPR 15
The maximum diameter of the lamp is 413 mm
Tube diameter 28 mm
40W
One-pin linear analog lamp with socket Fa6
LN Fa6
A pair of sockets LN Fa6
Single socket length 75 mm
The tube set corresponds to the required series of RS Fa6 / xxx
RS Fa6 / 1200
Lamp Size - LN Fa6
Maximum lamp length 1200 mm
Tube length 1050 mm
Tube diameter 28 mm
32W
RS Fa6 / 1500
Lamp Size - LN Fa6
Lamp maximum length 1500 mm
Tube length 1350mm
Tube diameter 28 mm
50W
relative devices
cone
Energy-saving lamp test equipment
With E27 socket according to Figure 7 b CISPR 15
cone
Option E14
Using additional adapter E27-E14
Insert the E14 lamp into the cone
cone
Option B22d
Using add-on adapter E27-B22d
Insert the B22d lamp into the cone.
cone
Option GU10
Using add-on adapter E27-GU10
Insert the GU10 lamp into the cone.