EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
IGUU2918 EMI calibration pulse and sine wave generator (9k-1G)
Brand:
SCHWARZBECK
- Product Description
- Main features
- Technical parameters
-
- Commodity name: IGUU2918 EMI calibration pulse and sine wave generator (9k-1G)
- Commodity ID: 1064725672556646400
- 品牌11: SCHWARZBECK
- 描述: The IGUU 2918 is used by every EMI receiver manufacturer and metrology organization and is the most widely used calibration pulse source in the world.
- 品牌: SCHWARZBECK
When calibrating the electromagnetic interference measurement receiver, especially when calibrating the impulse response characteristics of the receiver according to the CISPR-16 standard, a pulse signal generator must be used. The IGUU 2918 is adopted by various EMI receiver manufacturers and metrology institutes, and is the most widely used calibration pulse source in the world.
-
main feature:
When calibrating the electromagnetic interference measurement receiver, especially when calibrating the impulse response characteristics of the receiver according to the CISPR-16 standard, a pulse signal generator must be used. The IGUU 2918 is adopted by various EMI receiver manufacturers and metrology institutes, and is the most widely used calibration pulse source in the world.
The IGUU 2918 consists of three signal sources: a main pulse generator, an auxiliary pulse generator and a sine wave generator. Since the calibration pulse generator itself has a sinusoidal signal generator, it does not need an external signal source when calibrating the pulse response characteristics of the EMI receiver. Through the dedicated interface, test software and coaxial switch, the calibration of the impulse response characteristics of the electromagnetic interference receiver can be automatically completed. The control software is based on WINDOWS operating system, with friendly interface and easy operation.
The optional coaxial switch unit KU 9618 can be controlled by IGUU 2918, and one of the four outputs of IGUU 2918 is connected to the equipment under test (EUT). There is no need to switch the coaxial connector during the test, which is convenient and time-saving.
All functions of IGUU 2918 can be fully controlled by computer through GPIB interface. If KU 9618 is selected, fully automatic testing can be realized.
-
1. Main generator:
Pulse frequency range:
0.1 Hz-20 Hz, 1-200 Hz, 10 Hz-2 kHz, 100 Hz-20 kHz in steps of 0.1Hz, 1 Hz, 10 Hz, 100 Hz
Frequency accuracy: ±2.3×10 -3 Hz
Pulse shape: almost square wave
Pulse width: Band A 270ns; Band B 6ns; Band C/D 0.3ns
Pulse polarity: positive /negative (switchable)
Pulse Amplitude: (CISPR Weighted QP):
Band A/B 10 - 70dB in 1dB steps
Band C/D 0 - 60 dB in 1dB steps
Maximum output voltage (across 50Ω load): 80V ~ 110V
Pulse Area setting at 60dB attenuator:
Corresponds to CISPR 16 standard QP detector, equal to 1mV rms across 50 ohms .
Frequency Flatness:
Typical values: ±0 to -0.5dB at the high end frequencies of Band A/B
Band C: typical value: ±0.5dB (30MHz-100MHz) (100MHz is the reference frequency for level calibration)
The level is between 200MHz-800MHz, +0.5dB to +1dB as the frequency increases, and decreases to ±0 to -1dB at 800MHz-1000MHz.
Level accuracy:
Band A/B: ±0.5 dB at 50 kHz, 1 MHz
Band C/D: ±0.8 dB at 100 MHz
2. Auxiliary generator:
Pulse frequency range:
Band A: 0.1Hz-2kHz,
Band B: 0.1Hz-50kHz,
Band C/D: 0.1 Hz-1000kHz,
0.1Hz – 999.9Hz, with a step of 0.1Hz
0.1kHz – 1000kHz in 0.1kHz steps
Pulse frequency accuracy: ±2.3×10 -3 Hz
Pulse width: Band A 70ns; Band B 5ns; Band C/D 1ns
Pulse amplitude: ( CISPR weighted QP):
Band A/B: 60dB fixed level
Band C/D: 40dB fixed level
Frequency Flatness:
Band A/B: same as main generator
Band C (D): typical value ±0.75 dB, 30MHz-1000MHz
3. Dimensions and weight
Dimensions 447mm x 180mm x 460mm (W x H x D); Weight: 12kg