EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Load Impedance for CA BS 200N, BS200NX Electronic Switches
Brand:
EMTEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Load Impedance for CA BS 200N, BS200NX Electronic Switches
- Commodity ID: 1064613358880837632
- 品牌11: EMTEST
- 行业: 民用
- 描述: The IEC 61000-4-4 standard Ed 3.0, published in 2012, recommends that capacitive coupling clamps should be calibrated with a 50 ohm coaxial load.
- 品牌: EMTEST
The IEC 61000-4-4 standard Ed 3.0, published in 2012, recommends that capacitive coupling clamps should be calibrated with a 50 ohm coaxial load. Connect the capacitive coupling clamp (HFK) to the 50 ohm output of the EFT/burst generator, and connect the flexible insulating plate inside the HFK to a 50 ohm coaxial load resistor, thereby suppressing the EFT of the capacitive coupling clamp. Variable/burst waveform for verification.
-
main feature:
Capacitive coupling clamp calibration kit according to IEC 61000-4-4 Ed.3
Extended CA EFT Kit Calibration Components for EFT/Burst Waveform Calibration of Capacitively Coupled Clamps
Contains 1 flexible sensor board measuring 1050 x 120mm
Including support attachment for positioning load resistors at 100 mm height
Standards compliant:
IEC 61000-4-4
EN 61000-4-4
CA HFK calibration settings:
Calibration of Capacitive Coupling Clamp
IEC 61000-4-4 Standard Ed 3.0 recommends calibration of capacitive coupling clamps. EM TEST has developed and designed CA HFK calibration components according to standard requirements. Calibration requires the following facilities:
CA HFK: with sensor board and support accessories
KW50: 50 ohm load resistor
AD-CA EFT: 4 mm/6mm adapter for connecting the connection sensor board to the F103 coaxial connector of the KW 50
Calibration settings:
The sensor board should be placed in the capacitive coupling clamp with the end of the connection adapter aligned with the edge of the coupling board. Connect the connection adapter AD-CA EFT with a low impedance connection strap and connect to the ground reference plane of the 50 ohm coaxial measurement terminal/attenuator. Connect the load resistor KW 50 to the AD-CA EFT adapter. Use the acrylic support attachment to position the KW 50 at the same height as the coupling clamp, 100 mm from the ground reference plane.
The distance between the sensor board and the KW 50 measuring terminal/attenuator should be less than 0.1 m.
This technical data sheet gives a schematic diagram of the setup.

Calibration of the coupling clamp:
For calibration of the capacitive coupling plane, the open circuit voltage of the EFT/burst generator (50 ohm output) needs to be set to: 2,000 V
The resulting output voltage across the KW 50 (50 ohm matching resistor) is: 1,000 V
Measuring voltage Vm: 10 V
Under 50 ohm input impedance, the voltage value measured by the oscilloscope: 5 V
Resulting attenuation (theoretical): 400:1

-
Specific indicators:
sensor board
Sensor Board Technical Data
describe
Sensor board with 4 mm connection plug
Input voltage
up to 5.0 kV
size
Insulation board
1,100 +/-5 mm x 130 +/-1 mm
copper foil
1,050 +/-5 mm x 120 +/-1 mm
copper foil thickness <0.5 mmweight
300 g
support
Insulation Support Accessories Technical Data
describe
Position the KW50 at a height of 100 mm when performing capacitive coupling clamp calibration
KW 50 height
100 mm +/- 1 mm
material
Acrylic
size
70 mm x 49 mm x 95 mm
weight
400 g
option
KW50
sensor board with 4mm
connection plugCoaxial 50 Ohm Load Resistor for EFT/Burst Transient Verification
AD-CA EFT
Adapter for matching sensor board to KW 50 load resistor
CA EFT Kit
Electrical Fast Transient/Burst Calibration Kit, consisting of:
- KW 50, 50 ohm load resistor
- KW 1000, 1,000 ohm load resistor
- AD-CA EFT, 4 mm / 6 mm adapter for connection to coaxial F103
connector (will load resistor connected to the sensor board)