EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Schwarzbeck LISN AMN
Brand:
SCHWARZBECK
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Schwarzbeck LISN AMN
- Commodity ID: 1064739665216163840
- 品牌11: SCHWARZBECK
- 描述: LISN Line Impedance Stabilization Network/AMN Artificial Power Network
- 品牌: SCHWARZBECK
LISN Line Impedance Stabilization Network/AMN Artificial Power Network.
Provide the necessary supply voltage (AC or DC) and current for the device under test ( EuT).
Coupling the interference voltage generated by the EUT and providing it to the receiver.
Provides a well-defined RF impedance to the Equipment Under Test ( EUT).
Prevent unwanted interference from the power supply (filter).
Protect the power supply from unwanted interference voltages generated by the equipment under test.
-
main feature:
- LISN Line Impedance Stabilization Network/AMN Artificial Power Network
- Provide the necessary supply voltage (AC or DC) and current for the device under test ( EuT).
- Coupling the interference voltage generated by the EUT and providing it to the receiver.
- Provides a well-defined RF impedance to the Equipment Under Test ( EUT).
- Protection against unwanted interference from the power supply (filter)
- Protects the power supply from unwanted interference voltages generated by the device under test
- We can distinguish three types of LISN: V-type, T-type and Delta-type LISN
- V-LISN measures the asymmetrical interference voltage between two lines L1 and ground or L2 and ground respectively. V-LISN is also called V-AMN, and V-LISN is currently the most commonly used LISN.
- There are two V-LISNs with different impedances . V-LISN with 5μH inductance (CISPR 16-1-2, CISPR 25, ISO 7637, DO160) is usually used for measuring vehicles, ships and aircraft, with DC or 400 Hz connected to the on-board power supply equipment. Another V-LISN of 50 μH is designed to operate at a mains frequency of 50 Hz or 60 Hz according to CISPR 16-1-2, MIL STD 461, and ANSI C63.4.
- The T-ISN (right side of Figure 2) measures the asymmetrical interference voltage (common-mode voltage) and provides it to the EMI receiver. T-ISN is typically used for measurements on telecommunications and data transmission equipment connected to symmetrical lines such as twisted pairs.
-
model
structure
impedance
Maximum continuous current
road number
options
NSLK 8117
V-LISN
(50 µH + 5 Ω) || 50 Ω
2 x 10 A
2
NSLK 8127
V-LISN
(50 µH + 5 Ω) || 50 Ω
2 x 16 A
2
RC, PLC
NSLK 8126
V-LISN
(50 µH + 5 Ω) || 50 Ω
2 x 16 A Schuko
4 x 16 A CEKON4
RC
NSLK 8128
V-LISN
(50 µH + 5 Ω) || 50 Ω
2 x 16 A Schuko and
4 x 32 A CEKON4
RC
NSLK 8163
V-LISN
(50 µH + 5 Ω) || 50 Ω
4 x 64 A CEKON
4
RC
CISPR 16-1-2 Wing Terminals
NNLK 8121
V-LISN
(50 µH + 5 Ω) || 50 Ω
4 x 50 (100) A
4
RC, high current, 400/700V, fan
NNLK 8122
V-LISN
(50 µH + 5 Ω) || 50 Ω
2 x 50 A
2
NNLK 8129
V-LISN
50 µH || 50 Ω
4 x 200 (300) A
4
RC, 400/700 V, Lufter
NNLK 8129-2 HV
V-LISN
50 µH || 50 Ω
2 x 200 (300) A
2
RC,TC
NNLK 8130
V-LISN
50 µH || 50 Ω
4 x 400 (500) A
4
RC
NNLK 8140
V-LISN
50 µH || 50 Ω
1 x 800 (1000) A
1
car
NNHV8123
V-LISN
5µH || 50 Ω
70 (100) A
1
NNHV 8123-200
V-LISN
5µH || 50 Ω
200 A
1
NNHV 8123-400
V-LISN
5µH || 50 Ω
400 A
1
NNBM 8124
V-LISN
(5µH + 1 Ω) || 50 Ω
70 (100) A
1
N-connector
NNBM 8124-200
V-LISN
(5µH + 1 Ω) || 50 Ω
200 A
1
N-connector
NNBM 8124-400
V-LISN
(5µH + 1 Ω) || 50 Ω
400 A
1
N-connector
NNBM 8126 A 890
V-LISN
5 µH || 50 Ω
70 (100) A
1
DO-160
BAN 8508
8A (DC)
1
BAN 8530
30A (DC)
1
military
NNBL 8225
V-LISN
(50 µH + 5 Ω) || 50 Ω
20 A
1
NNBL 8226
V-LISN
(50 µH + 5 Ω) || 50 Ω
70 (100) A
1
NNBL 8226-HV
V-LISN
(50 µH + 5 Ω) || 50 Ω
70 (100) A
1
NNBL 8226-2
V-LISN
(50 µH + 5 Ω) || 50 Ω
70 (100) A
2
NNBL 8229-HV
V-LISN
(50 µH + 5 Ω) || 50 Ω
200 A
1
NNBL 8230
V-LISN
(50 µH + 5 Ω) || 50 Ω
300 A
1
NNBL 8240
V-LISN
(50 µH + 5 Ω) || 50 Ω
800 (1000) A
1
NTFM 8131
T-ISN
150 Ω ± 10%
3 A (AC)
2
NTFM 8158
T-ISN
150 Ω ± 20 Ω
600 mA DC (pair)
2
CAT5 8158
T-ISN
150 Ω ± 20 Ω
600 mA DC (pair)
2
CAT3 8158
T-ISN
150 Ω ± 20 Ω
600 mA DC (pair)
2
ISN S8
T-ISN
150 Ω ±20 Ω
150 Ω + 60 Ω /-45 Ω1A (DC)
8
ISN S1
T-ISN
150 Ω ±20 Ω
150 Ω + 60 Ω /-45 Ω1A (DC)
1
Pilot ISN
150 Ω ±20 Ω
1.4A DC
2
ECSS LISN1
(1.5 µH) || 50 Ω
10 A
2
ECSS LISN 2
(2 µH) || 50 Ω
10 A
2
ECSS LISN 2 - 75A
(2 µH) || 50 Ω
75 A
2
ECSS LISN 3
(0.7 µH) || 50 Ω
10 A
2
NPLC 8500
V-LISN
1 Oh
16 A
1
PVDC 8300
PV-LISN
Universal150 Ω common
100 Ω differential50 A (100 A with opt. fans)
2
Fans
PVDC 8301
PV-LISN
Universal150 Ω common
100 Ω differential200 A
2
TEMP 8400
Tempest-
V-LISN
1.4 kΩ
16 A
2
TEMP 8401