Wisdom

Product


EMC Testing Solution Provider


UCS 500N7 Industrial electronic test ultra-small anti-jamming signal simulator

Brand:

EMTEST

UCS 500N7 Industrial electronic test ultra-small anti-jamming signal simulator
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: UCS 500N7 Industrial electronic test ultra-small anti-jamming signal simulator
    • Commodity ID: 1064534920727777280
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: UCS 500N7 - State-of-the-art ultra-miniature combined immunity test equipment, fully compliant with IEC 61000-4-x and ANSI / IEEE C62.41 standards.
    • 品牌: EMTEST

      UCS 500N7 - State-of-the-art ultra-miniature combined immunity test equipment, fully compliant with IEC 61000-4-x and ANSI / IEEE C62.41 standards.

      UCS 500N7 ultra-small simulator is a multi-functional test equipment that can meet various requirements of international standards (basic standards and common standards) and product series standards for transient, pulse, surge and voltage drop tests. The test voltage can be up to up to 7.0 kV.

      For surge testing, in addition to meeting the requirements of IEC 61000-4-5, it also meets the testing requirements of ANSI / IEEE C62.41 for surge and ringing waves. UCS 500N7 is also the most economical fully compatible immunity test solution, which meets all requirements of EU CE certification immunity test. The built-in coupling/decoupling network is suitable for single-phase equipment testing, and the automatic control external coupling network (up to 100 A) can also be used for three-phase equipment testing.

  • main feature:

      Ultra-compact anti-interference signal simulator with test voltage up to 7.0 kV

      Electrical Fast Transient Burst Module (IEC / EN 61000-4-4)

      Surge Module (IEC / EN 61000-4-5 Ed 3.0/-9)

      Voltage drop module (IEC / EN 61000-4-11)

      Ring wave module (IEC / EN 61000-4-12) option

      Communication surge module (IEC / EN 61000-4-5) option

      Power frequency magnetic field, pulse magnetic field test accessories - optional

      Built-in 300 V / 16 A single-phase coupling network

      USB and GPIB-BUS interface for remote control

      Front panel manual operation

      Peak voltage and peak current monitoring output ports

      Failure detection function

      0 - 10 V DC signal controls external automatic voltage regulator

      Can control external three-phase coupling network

    Standards compliant:

      ANSI/IEEE C62.41

      ECE-R10

      IN 61000-4-11

      IN 61000-4-12

      IN 61000-4-29

      EN 61000-4-4

      EN 61000-4-5

      IN 61000-4-8

      IN 61000-4-9

      EN 61000-6-1

      EN 61000-6-2

      IN 61543

      IEC 60255-22-5

      IEC 61000-4-11

      IEC 61000-4-12

      IEC 61000-4-29

      IEC 61000-4-4

      IEC 61000-4-5

      IEC 61000-4-8

      IEC 61000-4-9

      IEC 61008-1

      IEC 61009-1

      IEC 61326

      IEC 61850-3

      IEEE 1547

      ITU-T K.20

      ITU-T K.21

      ITU-T K.45

      UL 1741

      UL 244

      UL 943

    advantage:

      UCS 500N7 is capable of fully compatible anti-jamming test, and the test level it can achieve far exceeds the general test requirements. Surge test voltage up to 7.0 kV, meeting IEC 61000-4-5 and ANSI / IEEE C62.41 standard requirements. By matching the built-in ring wave module (option), UCS 500N7 can also conduct ring wave tests on power lines in compliance with ANSI / IEEE C62.41 and IEC 61000-4-12 standards.

      The UCS 500N7 can be manually operated directly from the front panel, or remotely controlled via the built-in USB or GPIB interface. The failure detection function allows the user to control the ongoing test sequence based on the status of the device under test. The monitoring output port (BNC) helps users to measure and verify signals conveniently. In addition, UCS 500N7 also has security features such as self-locking and indicator lights.

      Pre-programmed standard test routines are easy to use. Through the quick start test program of UCS 500N7, the user can adjust the test parameters online during the test, so as to evaluate the sensitivity threshold of a single device under test. This feature is most suitable for product development testing.

      Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.

    controlling software:

      Control and report generation software iec.control

      iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.

      iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.

    Other models:

      UCS 500N series ultra-compact anti-interference signal simulators are used for EFT/Burst, Surge and Voltage Dip tests, including two test levels of simulators, the highest test voltage can reach 5.5 kV and 7 kV respectively.

    Accessory equipment:

      CNI 503 - Three-phase coupling/decoupling network for burst and surge testing

      EM TEST provides a series of fully automatic three-phase coupling/decoupling networks for burst and surge testing to expand the testing capabilities for three-phase equipment under test. The nominal current of the network can be up to 100 A.

      variac NX-1-260-16 - Automatic voltage regulator for voltage change testing

      The variac NX-1-260-16 automatic voltage regulator is an alternative test solution for tapped transformers, capable of performing voltage dips, short interruptions and voltage changes in accordance with the requirements of the IEC 61000-4-11 standard. In addition, it can be used for automatic magnetic field testing.

      V 4780 - Fixed tap transformer for voltage dips and short interruption tests

      The V 4780 fixed tap transformer provides the voltage required for voltage dip and short interruption tests as required by the IEC 61000-4-11 Ed.2:2004 standard.

      V 4780S2 - Tapped transformer for voltage dips and short interruption tests

      The V 4780S2 tapped autotransformer supplies the required voltage for voltage dip and short interruption tests according to IEC 61000-4-11 Ed.2:2004. In contrast to the manually operated V 4780, the V 4780S2 can automatically switch taps according to the selected voltage level.

      CNV 504N/508N - Signal/Data Line Coupling/Decoupling Networks for Surge Testing

      CNV 504N / 508N coupling/decoupling network can couple surge pulses to I/O lines, signal/data lines and communication lines, meeting the requirements of IEC 61000-4-5 Ed 3.0 standard.

    appendix:

      MS 100N - Magnetic field coil for power frequency and pulsed magnetic field testing

      MS 100N is a 1 m * 1 m magnetic field coil, which meets the requirements of IEC / EN61000-4-8 and IEC / EN 61000-4-9 standards. The coil moves easily, is height-adjustable, and swivels 360 degrees. When it is necessary to generate low-level power frequency magnetic field strength, the current transformer MC 2630 can be used together. For high-level field strength tests above 100 A/m, MC 26100 current transformers are required.

      CCI - Capacitive Coupling Clamp

      CCI capacitive coupling clamps fully meet the requirements of the IEC 61000-4-4 standard.

      ITP - Immunity Test Probe Assembly

      ITP is a product development diagnostic test tool. It includes a variety of near-field probes that can locate weak points in a system or on a printed circuit board. A burst simulator is used to generate interference signals.

      CA EFT kit - Electrical Fast Transient/Burst Calibration Kit

      According to the requirements of the IEC 61000-4-4 Ed.2 standard, the characteristics of the burst generator are verified by two different loads of 50 ohm and 1,000 ohm. EM TEST provides users with calibration components including these two load resistors and an adapter to verify the output port of the device under test.

      CCI PVKIT 1 - Capacitive Coupled Clamp Calibration Kit

      The IEC/EN 61000-4-4 standard Ed 3.0, published in 2012, recommends calibrating capacitive coupling clamps with a 50 ohm coaxial load. Connect the capacitive coupling clamp HFK to the 50 ohm output port of the electrical fast/transient burst simulator, and connect the insulating plate on the CCI/HFK to a 50 ohm coaxial load resistor, then the electrical fast transient of the capacitive coupling clamp can be Variable/burst waveform for verification.

  • Specific indicators:

    Electrical Fast Transient Bursts
    The burst module EFT/N7 complies with EN/IEC 61000-4-4 Ed 3.0 and EN 61000-6-1, -6-2 standards
    Test voltage 200 V - 5,500 V ± 10%;
    100 V - 2,750 V ± 10%, 50ohm load
    Pulse waveform 5 / 50 ns, 50 ohm and 1,000 ohm loads  
    rise time tr 5 ns ± 30% into 50 ohm load;
    5 ns ± 30% into 1,000 ohm load
    Pulse duration td 50 ns ± 30%, 50 ohm load;
    50 ns -15 / +100ns, 1,000 ohm load
    source impedance 50 ohm
    polarity positive, negative
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1° (16 - 500 Hz)
    burst duration td = 0.10 ms - 999 ms
    repetition rate tr = 10 ms - 9,999 ms
    Spike frequency f = 0.1 kHz - 1,000 kHz
    test duration T = 0:01 min - 99:59 min
    T > 99:59 min --> infinite
    output
    CRO trigger Oscilloscope 5 V trigger signal
    direct output Via 50 ohm coaxial connector
    Coupling method L, N, PE and various combinations
    The power supply of the device under test AC 300 V / 16 A, 50 / 60 Hz;
    DC 300 V / 16 A
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure According to IEC 61000-4-4, test level 1 - 4
    according to EN 61000-6-1, -6-2
    Manual setting of standard test procedures
    user testing program Synchronous burst output
    Random burst output
    Change voltage after T time
    Sweep fixed number of pulses within single burst
    Sweep
    fixed burst duration
    Change polarity after sweep T time
    option
    CCI Capacitive coupling clamp according to IEC 61000-4-4 standard
    KW 50 100:1 Voltage Divider, 50 ohm
    KW 1000 500:1 Voltage Divider, 1,000 ohm
    CA EFT kit Burst calibration kit, including KW50, KW1000, DUT port adapter and suitcase
    CCI PVKIT 1 Capacitive coupling clamp calibration adapter kit, consisting of
    - sensor board: conforming to IEC / EN 61000-4-4 standard Ed 3.0
    - support accessory: fixes the KW 50 adapter at the same
    100 mm height as the capacitive coupling clamp
    CA MC F Adapter, match the KW 50 load resistance to the power supply port of the equipment under test of the three-phase N series coupling network
    A6dB 6 dB attenuator, 50 ohms
    E.T.C Immunity test probe (generates electric field)
    ITP/H Immunity test probe (generates magnetic field)
    Combined wave/surge
    Surge module VCS/N7 complies with EN/IEC 61000-4-5 Ed 3.0 and EN 61000-6-1, -6-2 standards
    open circuit voltage 250 V - 7,000 V ± 10%
    Front time 1.2 us ± 30%  
    Pulse half peak time 50 us ± 20%
    short circuit current 3,500 A max ± 10%
    Front time 8 us ± 20%
    Pulse half peak time 20 us ± 20%
    polarity positive, negative, alternating
    counter 1 - 30,000 or unlimited, optional
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1°
    repetition rate Up to 0.5 Hz (2 s - 999 s)
    output
    CRO trigger Oscilloscope 5 V trigger signal
    direct output Output to external coupling network via high voltage connector (Zi = 2 ohm, optional adapter IMN 2)  
    Coupling method According to IEC 61000-4-5:
    Line-to-Line, 2 ohm; Line-to-Earth, 12 ohm
    To ANSI/IEEE C62.41:
    Line-to-Line, 2 ohm; Line-to-Earth, 2 ohm  
    The power supply of the device under test AC 300 V / 16 A, 50 / 60 Hz;
    DC 300 V / 16 A
    Measurement
    CRO voltage monitoring 10 Vp corresponds to 7,000 V
    CRO current monitoring 10 Vp corresponds to 3,500 A
    peak voltage 7,000 V, LCD display
    peak current 3,500 Amps, LCD display
    overcurrent protection When the inrush current exceeds the limit value, interrupt the inrush test
    Differential mode limiter
    Common mode limiter
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure According to IEC 61000-4-5, test level 1 - 4
    according to EN 61000-6-1, -6-2
    Manual setting of standard test procedures
    user testing program Change polarity after N pulses
    Change coupling after N pulses
    Change voltage after N pulses
    Change phase angle after N pulses
    Pulse Magnetic Field Test Procedure Compliant with IEC 61000-4-9, test levels 100, 300 and 1,000 A/m Test levels are continuously adjustable in the quick start menu
    option
    CNV 504Nx 4-wire signal line/data line coupling network
    according to IEC 61000-4-5 standard Ed 3.0
    CNV 508Nx 8-wire signal line/data line coupling network
    according to IEC 61000-4-5 standard Ed 3.0
    CNI 508N2 Network Group Coupling/decoupling network and protection network group for unshielded and shielded high-speed communication line (Ethernet line) testing
    IMN 2 Impedance matching adapter for matching direct output to 2 ohm source impedance
    Voltage dips, short interruptions and voltage changes
    Voltage drop module PFS/N7 complies with EN/IEC 61000-4-11 and EN 61000-6-1, -6-2 standards
    Channel PF1 / PF2 AC Voltage: Up to 300 V
    AC Current: Up to 16 A
    frequency
     
    16 Hz - 500 Hz  
    switch off time < 5 us, 100 ohm resistive load
    electric shock > 500 A
    Protect Both channels are short-circuit protected
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1° (16 - 500 Hz)
    repetition rate 10 ms - 9,999 s
    event duration 20 us - 9,999 s
    output
    CRO trigger Oscilloscope 5 V trigger signal
    DUT terminal L, N sum PE
    Measurement
    voltage monitoring Measure the voltage of the device under test, built-in 100:1 voltage divider
    current monitoring Measure EUT current 10 mV/A, 1,000 A maximum
    DUT voltage LCD display
    DUT current LCD display
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure Conforms to IEC 61000-4-11 standard, suitable for AC power supply test
    Conforms to IEC 61000-4-29 standard, suitable for DC power supply test
    Conforms to EN 61000-6-1, -6-2 standard
    Manual setting standard test procedure
    user testing program Control voltage change by external voltage regulator
    Change phase angle after N events
    Change event duration after N events
    Inverting mode
    50 / 60 Hz magnetic field test Complies with IEC / EN 61000-4-8
    with external current transformer MC 2630 for test classes 1, 3, 10 and 30 A / m with external current transformer MC 26100 for test classes 100, 300 and 1,000 A / m
    option
    In 4780 Transformer, fixed tap
    conforming to IEC / EN 61000-4-11 Ed.2
    V 4780S2 Autotransformer with automatic tap change
    according to IEC / EN 61000-4-11 Ed.2
    variac  NX-1-260-16 Automatic voltage regulator (0 - 260 V, 16 A)
    MS 100N Field Coil, 1 mx 1 m
    MC 2630 Current transformers for magnetic field testing up to 30 A/m
    MC 26100 Current transformers for magnetic field testing up to 1,000 A/m
    CA PFS Inrush current calibration components comply with IEC 61000-4-11 standard
    CA PFS-100R 100 ohm low inductance load resistors for rise and fall time verification
    ringing wave
    Ring wave module RWG / N7 (option) complies with ANSI / IEEE C62.41 and EN / IEC 61000-4-12 standards
    Test voltage 200 V - 6,000 V ± 10%;
    Voltage Waveform (open circuit)
    First peak rise time tr 0.5 us ± 30%
    Oscillation frequency 100 kHz ± 10%
    attenuation Peak 2 - Peak 1 = 40 - 110%
    Peak 3 - Peak 2 = 40 - 80%
    Peak 4 - Peak 3 = 40 - 80%
    electric current Waveform (short circuit)
    rise time tr <= 1.0 us
    Oscillation frequency 100 kHz ± 10%
    source impedance 12 ohms and 30 ohms
    peak current Depends on selected source impedance
    polarity positive, negative
    Ring wave module RWG / N7.1 (option) complies with UL 244, UL 1741, ANSI / IEEE C62.41 and EN / IEC 61000-4-12 standards
    Test voltage 250 V - 6,000 V ± 10%;
    Voltage Waveform (open circuit)
    First peak rise time tr 0.5 us ± 30%
    Oscillation frequency 100 kHz ± 10%
    attenuation Peak 2 - Peak 1 = 40 - 110%
    Peak 3 - Peak 2 = 40 - 80%
    Peak 4 - Peak 3 = 40 - 80%
    electric current Waveform (short circuit)
    rise time tr <= 1.0 us
    Oscillation frequency 100 kHz ± 10%
    source impedance 12 ohm and 30 ohm and 50 ohm  
    peak current Depends on selected source impedance
    polarity positive, negative
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1°
    repetition rate Up to 1 Hz (1 s - 999 s)
    Measurement
    CRO voltage monitoring 10 Vp corresponds to 7,000 V
    CRO current monitoring 10 Vp corresponds to 3,500 A
    output
    CRO trigger Oscilloscope 5 V trigger signal
    direct output Via High Voltage Safety Lab Connectors
    Coupling method L, N, PE; line-line; line-ground
    The power supply of the device under test AC 300 V / 16 A, 50 / 60 Hz;
    DC 300 V / 16 A
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    communication surge
    Communication surge module TSURGE7
    open circuit voltage 250 V - 7,000 V ± 10%
    Energy storage capacitor 20 uF
    polarity positive, negative, alternating
    counter 1 - 30,000 or unlimited, optional
      ITU and ETSI standards
    Front time 10 us ± 30%  
    Pulse duration 700 us ± 20%
      FCC part 68 standard pulse B
    Front time 9 us ± 30%  
    Pulse duration 720 us ± 20%
    Output current 6 A - 175 A (short circuit)
    Rise Time 5 us ± 30%
    Pulse duration 320 us ± 20%
      IEC 61000-4-5 standard
    Rise Time 10 us ± 30%  
    Pulse duration 700 us ± 20%
    Output current 6 A - 175 A (short circuit)
    Rise Time 5 us ± 20%
    Pulse duration 320 us ± 20%
    trigger circuit
    trigger method Automatic, manual, external trigger
    repetition rate Up to 0.33 Hz (3 s - 999 s)
    output
    ITU and ETSI standards 2 wires T1 and T2, each 25 ohm load
    FCC part 68 standard pulse B 2 wires T1 and T2, each 25 ohm load
    IEC 61000-4-5 standard 4 wires T1, T2, T3 and T4, each 25 ohm load
      For other test requirements, special output settings can be made
    option
    CNV 504T5 4-wire unshielded symmetrical line (communication line) coupling and decoupling network
    according to IEC 61000-4-5 standard Ed 3.0 (fig. 10)  
    CNV 508T5 8-wire unshielded symmetrical line (communication line) coupling and decoupling network
    conforming to IEC 61000-4-5 standard Ed 3.0 (fig. 10)  
    general data
    interface
    serial interface USB
    parallel interface IEEE 488, addresses 1 - 30
    analog output External voltage regulator controlled by 0 - 10 V DC voltage analog signal
    Coupled network interface 15-pin SubD interface, control external coupling network
    failure detection Monitor the device under test through failure detection port 1 and failure detection port 2
    Safety
    safety standard EN/IEC 61010 standard
    safety circuit Control input (24 V DC)
    Warning Light Floating contact (up to 230 V / 6 A)
    general data
    size and weight 19" /6 HU, about 29 kg
    supply voltage 115 / 230 V +10 / -15%
    power, frequency
    ,
    Approx. 75W, 50/60Hz  
    fuse 2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)
    Host comes with accessories
    host power cord Plug type depends on the country of use
    DUT power cord Plug type depends on the country of use
    EUT Adapter Socket type depends on the country of use
      Operation Manual
      Calibration certificate
    option
    CNI 503Bx Three-phase coupling/decoupling network up to 100 A per phase
    Compliant with IEC 61000-4-4 and IEC 61000-4-5
    iec.control 1 Remote control and reporting software including standard test procedures and report generation.
    OptoLink Visual interface, 3m optical fiber, USB A connector, replaceable USB interface