EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
TSS 500N10 Communication Surge Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: TSS 500N10 Communication Surge Simulator
- Commodity ID: 1064534073490952192
- 品牌11: EMTEST
- 行业: 民用
- 描述: TSS 500N10 - Communication Surge Generator, can generate 10/700 us test pulse
- 品牌: EM TEST
TSS 500N10 - Communication Surge Generator, can generate 10/700 us test pulse
Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N series communication surge simulator is an electromagnetic compatibility test instrument used to verify the immunity of communication equipment.
The TSS 500N4 complies with the test requirements of IEC 61000-4-5 and related standards, ITU-T standards and FCC 97-270 (part 68) standards for surge B pulses. In addition, it can generate 1.2 / 50 us surge voltage pulses that meet the EN / IEC 60950 standard.
-
main feature:
Stand-alone test equipment, meeting the test requirements of EN / IEC 61000-4-5 standard for 10 / 700us pulse
Test voltage up to 10 kV
Higher level testing to meet ITU-T standards
Meets the test requirements of the FCC part 68 standard for surge pulse B
Built-in coupling/decoupling networks for 2-wire and 4-wire test applications
Front panel operation
Standard Test Procedure
USB (optical) and GPIB interface
Standards compliant:
IN 60950-1
EN 61000-4-5
FCC 97-270 (part 68)
IEC 60065
IEC 60950-1
IEC 61000-4-5
ITU-T K.17
ITU-T K.20
ITU-T K.21
ITU-T K.28
ITU-T K.45
advantage:
TSS 500N10 - Test equipment integrating 10/700us pulse generator and coupling network
The TSS 500N10 is an ultra-compact simulator capable of generating 10 / 700 us and 9 / 720 us communication surge pulses, and 1.2 / 50 us voltage surge pulses.
The TSS 500N10 is not only a pulse simulator but also has a built-in coupling network for 2-wire and 4-wire test applications. Its output terminal can be directly connected with the communication port of the equipment under test. In addition, EM TEST offers coupling networks suitable for 4-wire or 8-wire communication line testing.
Pre-programmed standard test routines are easy to use. TSS 500N10 also provides a quick start test program, the user can adjust the test parameters online during the test, so as to evaluate the sensitivity level of a single device under test.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
Accessory equipment:
CNV 504T5/508T5 - Coupling/Decoupling Networks for Communication Line Surge Tests
CNV 504T5 / 508T5 Coupling Networks are suitable for surge surge testing of communication lines according to EN / IEC 61000-4-5. Two models are available for different applications with 4-wire and 8-wire. The decoupling network consists of pairs of current compensating inductors. The coupling of the surge pulses is realized by means of gas discharge tubes according to EN / IEC 61000-4-5.
-
Specific indicators:
Compliant with ITU and ETS standards open circuit voltage 500 V - 10,000 V ± 10% Pulse 1.2 / 50us Pulse 10 / 700us Rise Time 1.0 us ± 30% 6.5 us ± 30% Pulse duration 50 us ± 20% 700 us ± 20% Energy storage capacitor 1 uF 20 uF polarity positive, negative, alternating counter 1 - 30,000 or unlimited Complies with FCC PART 68, Pulse B open circuit voltage 500 V - 10,000 V ± 10% Front time 9 us ± 30% 5 us ± 30% Pulse duration 720 us ± 20% 320 us ± 20% short circuit current 12.5 - 250 A T1 - COM or T2 - COM Energy storage capacitor 20 uF polarity positive, negative, alternating counter 1 - 30,000 or unlimited Conforms to IEC 61000-4-5 standard pulse 10 / 700 us open circuit voltage 500 V - 10,000 V ± 10% Rise Time 10 us ± 30% 5 us ± 20% Pulse duration 700 us ± 20% 320 us ± 20% short circuit current 12.5 - 250 A T1 - COM or T2 - COM Energy storage capacitor 20 uF source impedance 40 ohm polarity positive, negative, alternating counter 1 - 30,000 or unlimited trigger trigger method Automatic, manual, external trigger CRO trigger Oscilloscope 5 V trigger signal coupling ITU-T standard 2 wires: T1 and T2 25 ohm each FCC part 68 standard 2 wires: T 1 and T2 25 ohm each wire IEC 61000-4-5 standard 4 wires: T1, T2, T3, T4, 25 ohm each test program Quick Start Instant start, simple and fast user testing program Change voltage after N pulses
Change polarity after N pulsesStandard Test Procedure IEC 61000-4-5 Level 1,000V
IEC 61000-4-5 standard, test level 2,000V
IEC 61000-4-5 standard, test level 4,000V
FCC part 68 standard, pulse B Transverse test 1,000V
FCC part 68 standard, pulse B Longitudinal test 1,500VServe service, setup, self-test interface serial interface Optical, 3 m cable USB Type A connector parallel interface IEEE 488, addresses 1 - 30 Safety safety circuit Control input (24 V DC) Warning Light floating output contact general data size and weight 19" / 9 HU, 420 mm x 448 mm x 500 mm, about 37.1 kg supply voltage 115 / 230 V +10 / -15% fuse 2 x T 2 AT(230 V)或 2 X T 4 AT(115 V) environment temperature 10 °C to 35 °C Relative humidity Max 85 %, non-condensing atmospheric pressure 86 kPa - 106 kPa Replaceable Waveform Module T1-N10 Built-in 0.5 / 700 us waveform module Test voltage up to 10 kV T2-N10 Built-in 100 / 700 us waveform module Test voltages up to 10 kV
Replaceable with an integrated waveform in the communication surge simulatoroption CNV 504T5 Coupling/decoupling network for 4-wire unshielded balanced line (communication line) test according to IEC/EN61000-4-5 standard Ed.3 (fig. 10) CNV 508T5 Coupling/decoupling network for 8-wire unshielded balanced line (communication line) test according to IEC/EN61000-4-5 standard Ed.3 (fig. 10) iso.control Remote control and report generation software including standard test procedures and reporting capabilities.