Wisdom

Product


EMC Testing Solution Provider


TSS 500N6B combined communication surge simulator

Brand:

EM TEST

TSS 500N6B combined communication surge simulator
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: TSS 500N6B combined communication surge simulator
    • Commodity ID: 1064533231283097600
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N s
    • 品牌: EM TEST

      Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N series communication surge simulator is an electromagnetic compatibility test instrument used to verify the immunity of communication equipment.

      The TSS 500N6B complies with the Bellcore GR-1089-Core standard for 4-wire test applications. With the use of CNB 500 coupling network (option), it can also support 12 pairs of communication line port tests. The device can also be used for 2-wire communication port testing.

  • main feature:

      Combined test equipment, Bellcore / Telcorida GR-1089-CORE compliant

      Test pulses for 4-wire communication surge test applications

      Simultaneous coverage of 2-wire communication port tests

      Can generate test pulses 10 / 360 us, 10 / 1,000 us and 2 / 10 us

      Includes all required matching resistors

      Built-in coupling network

      Support 12-pair test (10 / 360 us pulse)

      Support manual operation

      Supports standard test procedures

      USB and GPIB interface

    Standards compliant:

      Bellcore GR-1089-Core

      ITU-T K.12

      ITU-T K.28

      ITU-T K.45

    advantage:

      TSS 500N6B - Contains all equipment tested to Bellcore standards for 4-wire applications

      TSS 500N series communication surge simulator is an electromagnetic compatibility testing instrument used to verify the immunity of communication equipment. TSS 500N6B was developed to provide a very easy-to-operate test equipment for communication surge testing, which meets the test requirements of Bellcore GR-1089-Core standard for 4-wire applications. The standard contains multiple test pulses requiring different source impedance values ​​to generate the pulses required by the Bellcore standard, Class 1 lightning pulse and indoor lightning surge tests, and AC power port tests. All these pulses can be generated by a single device, the TSS 500N6B.

      The TSS 500N6B also integrates the coupling/decoupling networks required to interface the communication ports (2-wire and 4-wire applications). A built-in switching loop automatically sets the simulator to generate the required test pulses based on the selected coupling mode. With the use of CNB 500 (option), TSS 500N6B also supports 10 / 360 us pulse test on 12 pairs of communication ports at the same time.

      Pre-programmed standard test routines are easy to use. In addition, TSS 500N4 also provides a quick start test program, users can adjust test parameters online during the test, so as to evaluate the sensitivity level of a single device under test.

      Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.

    controlling software:

      Control and report generation software iec.control

      iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.

      iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.

    Accessory equipment:

      CNB 500 - Coupling network for 12 pairs of positive and negative conductors

      The CNB 500 coupling network is suitable for applying the Class 1 lightning surge test required by the Bellcore GR-1089-Core standard to 12 pairs of positive and negative conductors simultaneously. The test pulse is a 10 / 360 us pulse with a current of 25 A at a test voltage of 1,000 V.

  • Specific indicators:

    4-wire port Class I lightning surge, pulse 10 / 1,000 US (600 V)
    open circuit voltage 50 V - 600 V -0 / +15%, positive/negative polarity  
    short circuit current 8 A - 100 A per line
    Rise Time 10 us +0 us / -4 us 6.5 us ± 30%
    Pulse duration 1,000 us +500 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 36 seconds at 600 V / 100 A per line  
    4-wire port Class 1 lightning surge, pulse 10 / 1,000 US (1000 V) , pulse 2 / 10 US  
    open circuit voltage 50 V - 1000 V -0 / +15%, positive/negative polarity  
    short circuit current 5 A - 100 A per line
    Rise Time 10 us +0 us / -4 us 6.5 us ± 30%
    Pulse duration 1,000 us +500 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 60 seconds at 1,000 V  
    4-wire port Class 1 lightning surge, pulse 10 / 360 US (1000 V) , pulse 2 / 10 US  
    open circuit voltage 50 V - 1000 V -0 / +15%, positive/negative polarity  
    short circuit current 5 A - 100 A per line
    Rise Time 10 us +0 us / -2.5 us 6.5 us ± 30%
    Pulse duration 360 us +108 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 20 seconds at 1,000 V  
    4-wire port Class 1 lightning surge, pulse 2 / 10 US (500 V)   , pulse 2 / 10 US  
    open circuit voltage 100 V - 2,500 V -0 / +20%, positive/negative polarity  
    short circuit current 20 A - 500 A per line
    Rise Time 2 us +0 us / -1 us 6.5 us ± 30%
    Pulse duration 10 us +7 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 5 seconds at 2,500 V  
    4-wire port Class 1 lightning surge, pulse 2 / 10 US (800 V)   , pulse 2 / 10 US  
    open circuit voltage 100 V - 800 V -0 / +20%, positive/negative polarity  
    short circuit current 12.5 A - 100 A per line
    Rise Time 2 us +0 us / -1 us 6.5 us ± 30%
    Pulse duration 10 us +7 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 2 seconds at 800 V / 100 A per line    
    4-wire port Class 1 lightning surge, pulse 2 / 10 US (000 V)   , pulse 2 / 10 US  
    open circuit voltage 100 V - 5,000 V -0 / +20%, positive/negative polarity  
    short circuit current 10 A - 500 A per line
    Rise Time 2 us +0 us / -1 us 6.5 us ± 30%
    Pulse duration 10 us +7 us / -0 us
    700 us ± 20%
    repetition rate 1 pulse every 10 seconds at 5,000 V    
    Measurement
    Peak Voltmeter 5,000 V ±10%  
    peak current meter 500 A ±10%
    trigger
    trigger method Automatic, manual, external trigger
    CRO trigger Oscilloscope 5 V trigger signal
    coupling
    Communication port
    (positive line T, negative line R,
    positive line T1 and negative line R1)
    When one line (T, T1, R, R1) is connected to the simulator, the other lines are connected to ground
    T1 and R1 are connected to ground when
    both T and R are connected to the simulator and R ground
    T, R, T1 and R1 are connected to the simulator at the same time      
    test program
    Quick Start Instant start, simple and fast
    user testing program Change the voltage after N pulses
    Change the polarity after N pulses
    Manually set the standard test procedure
    Standard Test Procedure GR-1089 CORE compliant test grade      
     Serve service, setup, self-test
    interface
    serial interface USB
    parallel interface IEEE 488, addresses 1 - 30
    Safety
    safety circuit Control input (24 V DC)
    Warning Light floating output contact
    general data
    size and weight 19" / 9 HU, about 45 kg
    supply voltage 115 / 230 V +10 / -15%
    fuse 2 x T 2 AT(230 V)或 2 X T 4 AT(115 V)
    environment
    temperature 10 °C to 35 °C  
    Relative humidity Max 85 %, non-condensing
    atmospheric pressure 86 kPa  - 106 kPa
    option
    CNB 500 Coupling/decoupling network for 10/360 us pulse testing on 12 pairs up to 1,000 V / 25 A per line
    iso.control Remote control and report generation software including standard test procedures and reporting capabilities.
    Other Models Compliant with GR-1089-CORE
    TSS 500N2B Communication surge simulator for Class 1 lightning protection test with test pulse of 10/1,000us up to 2,000 V