EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
TSS 500N6B combined communication surge simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: TSS 500N6B combined communication surge simulator
- Commodity ID: 1064533231283097600
- 品牌11: EMTEST
- 行业: 民用
- 描述: Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N s
- 品牌: EM TEST
Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N series communication surge simulator is an electromagnetic compatibility test instrument used to verify the immunity of communication equipment.
The TSS 500N6B complies with the Bellcore GR-1089-Core standard for 4-wire test applications. With the use of CNB 500 coupling network (option), it can also support 12 pairs of communication line port tests. The device can also be used for 2-wire communication port testing.
-
main feature:
Combined test equipment, Bellcore / Telcorida GR-1089-CORE compliant
Test pulses for 4-wire communication surge test applications
Simultaneous coverage of 2-wire communication port tests
Can generate test pulses 10 / 360 us, 10 / 1,000 us and 2 / 10 us
Includes all required matching resistors
Built-in coupling network
Support 12-pair test (10 / 360 us pulse)
Support manual operation
Supports standard test procedures
USB and GPIB interface
Standards compliant:
Bellcore GR-1089-Core
ITU-T K.12
ITU-T K.28
ITU-T K.45
advantage:
TSS 500N6B - Contains all equipment tested to Bellcore standards for 4-wire applications
TSS 500N series communication surge simulator is an electromagnetic compatibility testing instrument used to verify the immunity of communication equipment. TSS 500N6B was developed to provide a very easy-to-operate test equipment for communication surge testing, which meets the test requirements of Bellcore GR-1089-Core standard for 4-wire applications. The standard contains multiple test pulses requiring different source impedance values to generate the pulses required by the Bellcore standard, Class 1 lightning pulse and indoor lightning surge tests, and AC power port tests. All these pulses can be generated by a single device, the TSS 500N6B.
The TSS 500N6B also integrates the coupling/decoupling networks required to interface the communication ports (2-wire and 4-wire applications). A built-in switching loop automatically sets the simulator to generate the required test pulses based on the selected coupling mode. With the use of CNB 500 (option), TSS 500N6B also supports 10 / 360 us pulse test on 12 pairs of communication ports at the same time.
Pre-programmed standard test routines are easy to use. In addition, TSS 500N4 also provides a quick start test program, users can adjust test parameters online during the test, so as to evaluate the sensitivity level of a single device under test.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
Accessory equipment:
CNB 500 - Coupling network for 12 pairs of positive and negative conductors
The CNB 500 coupling network is suitable for applying the Class 1 lightning surge test required by the Bellcore GR-1089-Core standard to 12 pairs of positive and negative conductors simultaneously. The test pulse is a 10 / 360 us pulse with a current of 25 A at a test voltage of 1,000 V.
-
Specific indicators:
4-wire port Class I lightning surge, pulse 10 / 1,000 US (600 V) open circuit voltage 50 V - 600 V -0 / +15%, positive/negative polarity short circuit current 8 A - 100 A per line Rise Time 10 us +0 us / -4 us 6.5 us ± 30% Pulse duration 1,000 us +500 us / -0 us
700 us ± 20%repetition rate 1 pulse every 36 seconds at 600 V / 100 A per line 4-wire port Class 1 lightning surge, pulse 10 / 1,000 US (1000 V) , pulse 2 / 10 US open circuit voltage 50 V - 1000 V -0 / +15%, positive/negative polarity short circuit current 5 A - 100 A per line Rise Time 10 us +0 us / -4 us 6.5 us ± 30% Pulse duration 1,000 us +500 us / -0 us
700 us ± 20%repetition rate 1 pulse every 60 seconds at 1,000 V 4-wire port Class 1 lightning surge, pulse 10 / 360 US (1000 V) , pulse 2 / 10 US open circuit voltage 50 V - 1000 V -0 / +15%, positive/negative polarity short circuit current 5 A - 100 A per line Rise Time 10 us +0 us / -2.5 us 6.5 us ± 30% Pulse duration 360 us +108 us / -0 us
700 us ± 20%repetition rate 1 pulse every 20 seconds at 1,000 V 4-wire port Class 1 lightning surge, pulse 2 / 10 US (500 V) , pulse 2 / 10 US open circuit voltage 100 V - 2,500 V -0 / +20%, positive/negative polarity short circuit current 20 A - 500 A per line Rise Time 2 us +0 us / -1 us 6.5 us ± 30% Pulse duration 10 us +7 us / -0 us
700 us ± 20%repetition rate 1 pulse every 5 seconds at 2,500 V 4-wire port Class 1 lightning surge, pulse 2 / 10 US (800 V) , pulse 2 / 10 US open circuit voltage 100 V - 800 V -0 / +20%, positive/negative polarity short circuit current 12.5 A - 100 A per line Rise Time 2 us +0 us / -1 us 6.5 us ± 30% Pulse duration 10 us +7 us / -0 us
700 us ± 20%repetition rate 1 pulse every 2 seconds at 800 V / 100 A per line 4-wire port Class 1 lightning surge, pulse 2 / 10 US (000 V) , pulse 2 / 10 US open circuit voltage 100 V - 5,000 V -0 / +20%, positive/negative polarity short circuit current 10 A - 500 A per line Rise Time 2 us +0 us / -1 us 6.5 us ± 30% Pulse duration 10 us +7 us / -0 us
700 us ± 20%repetition rate 1 pulse every 10 seconds at 5,000 V Measurement Peak Voltmeter 5,000 V ±10% peak current meter 500 A ±10% trigger trigger method Automatic, manual, external trigger CRO trigger Oscilloscope 5 V trigger signal coupling Communication port
(positive line T, negative line R,
positive line T1 and negative line R1)When one line (T, T1, R, R1) is connected to the simulator, the other lines are connected to ground
T1 and R1 are connected to ground when
both T and R are connected to the simulator and R ground
T, R, T1 and R1 are connected to the simulator at the same timetest program Quick Start Instant start, simple and fast user testing program Change the voltage after N pulses
Change the polarity after N pulses
Manually set the standard test procedureStandard Test Procedure GR-1089 CORE compliant test grade Serve service, setup, self-test interface serial interface USB parallel interface IEEE 488, addresses 1 - 30 Safety safety circuit Control input (24 V DC) Warning Light floating output contact general data size and weight 19" / 9 HU, about 45 kg supply voltage 115 / 230 V +10 / -15% fuse 2 x T 2 AT(230 V)或 2 X T 4 AT(115 V) environment temperature 10 °C to 35 °C Relative humidity Max 85 %, non-condensing atmospheric pressure 86 kPa - 106 kPa option CNB 500 Coupling/decoupling network for 10/360 us pulse testing on 12 pairs up to 1,000 V / 25 A per line iso.control Remote control and report generation software including standard test procedures and reporting capabilities. Other Models Compliant with GR-1089-CORE TSS 500N2B Communication surge simulator for Class 1 lightning protection test with test pulse of 10/1,000us up to 2,000 V TSS 500N4B Bellcore compliant 4 kV / 2 kA communication surge simulator, suitable for lightning surge and broadband communication tests in high exposure environments, the test pulse is 10 / 250 us, up to 4 kV / 2 kA