EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
TSS 500N4 Communication Surge Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: TSS 500N4 Communication Surge Simulator
- Commodity ID: 1064532426899476480
- 品牌11: EMTEST
- 行业: 民用
- 描述: TSS 500N4 - Small communication surge generator for 10/700 us test pulses
- 品牌: EM TEST
TSS 500N4 - Small communication surge generator for 10/700 us test pulses
Communication networks are easily disturbed by lightning strikes, so communication equipment connected to outdoor devices/equipment needs to have proper protection against surge pulse interference in order to work normally in lightning weather. TSS 500N series communication surge simulator is an electromagnetic compatibility test instrument used to verify the immunity of communication equipment.
The TSS 500N4 complies with the test requirements of IEC 61000-4-5 and related standards, ITU-T standards and FCC 97-270 (part 68) standards for surge B pulses.
-
main feature:
· Discrete test equipment for 10 / 700 us pulses according to IEC 61000-4-5
·Compliant with ITU-T standard
Comply with the test requirements of the FCC part 68 standard for surge B pulse
Built-in coupling/decoupling network for 2-wire and 4-wire test applications
·Support manual operation
·Support standard test procedures
·USB and GPIB interface
Standards compliant:
IN 60950-1
EN 61000-4-5
FCC 97-270 (part 68)
IEC 60065
IEC 60950-1
IEC 61000-4-5
ITU-T K.17
ITU-T K.20
ITU-T K.28
ITU-T K.45
advantage:
TSS 500N4 - test equipment with 10/700 us pulse generator and coupling network in one
TSS 500N4 is an ultra-small integrated test equipment capable of generating communication surge pulses of 10/700 us, 9/720 us and voltage surge pulses of 1.2/50 us.
The TSS 500N4 is not only a pulse generator but also has a built-in coupling network for 2-wire and 4-wire test applications. Its output can be directly connected to the communication port of the device under test. In addition, EM TEST offers coupling networks suitable for testing 4-wire or 8-wire communication lines.
Pre-programmed standard test procedures are very easy to use. In addition, TSS 500N4 also provides a quick start test program, allowing users to adjust test parameters online during the test to evaluate the sensitivity level of a single device under test.
Through the front panel menu and function keys, users can edit test programs quickly and accurately. The control cursor is used to quickly control all test parameters of the programmed test program, making the test process very simple and ensuring that each test step can be performed correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It automatically recognizes the connected EM TEST test equipment and configures it automatically. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is accomplished via USB or GPIB interface. iec.control is compatible with various GPIB cards from NI.
Accessory equipment:
CNV 504/508 - Coupling network for surge testing of communication lines
Coupling networks CNV 504S1 and CNV 508S1 can meet the requirements of the IEC 61000-4-5 standard for surge testing of communication lines. They are suitable for 4-wire or 8-wire test applications respectively. The decoupling network consists of a pair of current compensating inductors. According to the requirements of the IEC 61000-4-5 standard, the coupling of the surge pulse is realized through the gas discharge tube.
-
Specific indicators:
Compliant with ITU and ETS standards open circuit voltage 160 V - 4,000 V±10% Pulse 1.2 / 50us Pulse 10 / 700us Rise Time 1.0 us ± 30% 6.5 us ± 30% Pulse duration 50 us ± 20% 700 us ± 20% Energy storage capacitor 1 uF 20 uF polarity positive, negative, alternating counter 1 - 30,000 or unlimited Complies with FCC PART 68, Pulse B open circuit voltage 160 V - 4,000 V±10% Front time 9 us ± 30% 5 us ± 30% decay time 720 us ± 20% 320 us ± 20% short circuit current 4 A - 100 A Energy storage capacitor 20 uF polarity positive, negative, alternating counter 1 - 30,000 or unlimited Conforms to IEC 61000-4-5 standard pulse 10 / 700 us open circuit voltage 160 V - 4,000 V±10% Front time 6.5 us ± 30% 4 us ± 20% decay time 700 us ± 20% 300 us ± 20% short circuit current 4 A - 100 A Energy storage capacitor 20 uF polarity positive, negative, alternating counter 1 - 30,000 or unlimited trigger trigger method Automatic, manual, external trigger CRO trigger Oscilloscope 5 V trigger signal coupling ITU-T standard 2 wires: T and R 25 ohm each wire FCC part 68 standard 2 wires: T and R 25 ohm each wire IEC 61000-4-5 standard 4 wires: T, R, T1, R1 25 ohm each test program Quick Start Instant start, simple and fast user testing program Change voltage after N pulses
Change polarity after N pulsesStandard Test Procedure IEC 61000-4-5 Level 1,000V
IEC 61000-4-5 standard, test level 2,000V
IEC 61000-4-5 standard, test level 4,000V
FCC part 68 standard, pulse B Transverse test 1,000V
FCC part 68 standard, pulse B Longitudinal test 1,500VServe service, setup, self-test interface serial interface USB parallel interface IEEE 488, addresses 1 - 30 Safety safety circuit Control input (24 V DC) Warning Light floating output contact general data size and weight 19" / 3 HU, about 20 kg supply voltage 115 / 230 V +10 / -15% fuse 2 x T 2 AT(230 V)或 2 X T 4 AT(115 V) environment temperature 10 °C to 35 °C Relative humidity Max 85 %, non-condensing atmospheric pressure 86 kPa - 106 kPa option CNV 504S1 4-wire communication line coupling network conforming to IEC61000-4-5 standard fig. 14 CNV 508S1 8-wire communication line coupling network, in line with IEC61000-4-5 standard fig. 14 iso.control Remote control and report generation software including standard test procedures and reporting capabilities.