EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
OCS 500N6 Damped Oscillatory Wave Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: OCS 500N6 Damped Oscillatory Wave Simulator
- Commodity ID: 1064530711873736704
- 品牌11: EMTEST
- 行业: 民用
- 描述: OCS 500N6 - Combined Ringwave and Damped Oscillatory Wave Simulator
- 品牌: EM TEST
OCS 500N6 - Combined Ringwave and Damped Oscillatory Wave Simulator
The OCS 500N6.8 simulator can perform ring wave tests with a test voltage up to 6 kV in accordance with EN / IEC 61000-4-12; it can also perform oscillation frequency tests in accordance with EN / IEC 61000-4-18 Damped oscillatory wave tests at 100 kHz / 1 MHz with test voltages up to 3 kV.
Ringing waves are non-repetitive damped oscillatory transients that occur on low-voltage power, control, and signal lines in public and non-public power grids. Damped oscillatory waves are reproducible transient phenomena that mainly occur on power, control and signal lines installed in high and medium voltage substations.
Together with the magnetic field coil MS 100N, the OCS 500N6.8 can also perform oscillating magnetic field tests according to EN / IEC 61000-4-10.
-
main feature:
Discrete Test Equipment
Ring wave test up to 6 kV
Damped shock wave test up to 3 kV
Built-in single-phase or three-phase coupling/decoupling network up to 100 A
Front panel operation
Standard Test Procedure
USB and GPIB interface
Standards compliant:
ANSI/IEEE C37.90
ANSI/IEEE C62.41
IN 61000-4-10
IN 61000-4-12
IN 61000-4-18
IEC 60255-22-1
IEC 61000-4-10
IEC 61000-4-12
IEC 61000-4-18
IEC 61850-3
advantage:
The stand-alone test set OCS 500N6 completes EM TEST for IEC 61000-4-x standard tests. It can generate a 6 kV ringing wave that meets the ANSI/IEEE C62.41 standard; at the same time, it can also generate a 3 kV damped oscillation wave at a frequency of 100 kHz and 1 MHz, which not only complies with EN/IEC 61000-4 -18 standard and also meets the relevant requirements of ANSI / IEEE C39.70 standard for testing protective relays and relay systems.
Damped oscillating waves can also be used to generate damped oscillating magnetic fields required by the EN / IEC 61000-4-10 standard (in combination with field coils, eg MS 100). The OCS 500N6 has a built-in coupling/decoupling network for single-phase or three-phase testing, capable of delivering a rated current of 16 A or 32 A per line, respectively.
Through the front panel menu or the built-in USB, GPIB interface, OCS 500N6 can realize both manual operation and remote control. Its failure detection function allows the user to control the ongoing test sequence based on the state of the device under test. The monitoring output port (BNC) is used to measure and verify the signal. The OCS 500N6 also includes safety features such as safety lock and warning light control.
Pre-programmed standard test routines provide maximum user convenience. In addition, OCS 500N6 also provides a quick-start test program with online adjustable parameters to evaluate the sensitivity level of the device under test.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
Accessory equipment:
CNV 504N5 - Signal/Data Line Coupling/Decoupling Networks
CNV 504N5 is a 4-wire coupling/decoupling network for coupling damped oscillatory waves onto signal/data lines with 200 ohm source impedance in accordance with EN / IEC 61000-4-18 standard requirements.
appendix:
MS 100N - Magnetic field coil for damped oscillating magnetic field testing
The MS 100N is a 1 m * 1 m magnetic field coil that complies with the requirements of the EN / IEC 61000-4-10 standard. The field coil is fixed on a movable, height-adjustable, and 360-degree rotatable stand.
Connect the MS 100N directly to the corresponding high-voltage output port of the OCS 500N6 to generate a damped oscillating magnetic field that meets the requirements of the EN / IEC 61000-4-10 standard, up to test level 5.
-
Specific indicators:
OCS 500N6 Series OCS 500N6 model OCS500N6.5 Built-in 250V/16A coupling and decoupling network OCS500N6.6 Built-in 250V/32A coupling and decoupling network OCS500N6.7 Built-in 3×440V/16A coupling and decoupling network OCS500N6.8 Built-in 3×440V/32A coupling and decoupling network OCS500N6.20 Built-in 3 x 690 V / 100 A coupling/decoupling networks RCCB test corresponds to OCS 500N6 model OCS500N6.17 Built-in 3×440V/32A coupling and decoupling network
calibrated according to IEC 61008-1 and IEC 61009-1Ring wave test in compliance with IEC61000-4-12 and ANSI/IEEC62.41 standards open circuit voltage 250V—6000V+/-10% Rise Time 0.5us+/-30% Oscillation frequency 100kHz+/-10% decay rate Peak 2-Peak 1=0.4-1.1
Peak 3-Peak 2=0.4-0.8
Peak 4-Peak 3=0.4-0.8source impedance 12 ohms and 30 ohms +/- 20% Short circuit peak current 500A max at 12 ohms
200A max at 30 ohms (internal)Rise Time <1us Oscillation frequency 100kHz+/-10% polarity positive/negative repetition rate 1 / min or faster Damped shock wave test in accordance with IEC61000-4-18 High voltage output open circuit voltage 250V—3000V+/-10% Open circuit voltage at line output 250V—2500V+/-10% Rise Time 75ns+/-20% Oscillation frequency 100kHz and 1MHz+/-10% attenuation Peak 5 > 50% of peak 1
Peak 10 < 50% of peak 1source impedance 200 ohms +/-20% polarity positive/negative repetition rate At 100kHz, up to 50/s; at 1M Hz, up to 500/s Pulse duration at least 2s trigger circuit release pulse automatic, manual, external Synchronize 0°-360°, resolution 1° CRO trigger Oscilloscope 5 V trigger signal output direct output Via High Voltage Safety Lab Connectors Coupling method line-line; line-ground Single-phase 16A DUT power supply AC: 250V/16A, 50/60Hz
DC: 250V/16ASingle-phase 32A DUT power supply AC: 250V/32A, 50/60Hz
DC: 250V/32AThree-phase 16A DUT power supply AC: 3×440V/16A, 50/60Hz
DC: 250V/16AThree-phase 32A DUT power supply AC: 3×440V/32A, 50/60Hz
DC: 250V/32AThree-phase 100A DUT power supply AC: 3 x 690 V / 100 A; 50 / 60 Hz
DC: 250 V / 100 AMeasurement ringing wave LCD display peak voltage and peak current test program Quick start test program Instant start, simple and fast Standard Test Procedure Conforms to IEC61000-4-12 Test Level 1-4
Manual Test Standard Test Procedure
Conforms to ANSI / IEEC62.41 Standard
Conforms to IEC61000-4-10 Test Level 1-5User-Defined Test Program Change the polarity after N pulses
Change the coupling mode after N pulses
Change the voltage after N pulses
Change the phase angle after N pulsesinterface serial interface USB parallel interface IEEE488, address 1-30 option CNV 504N5.1 4-wire Signal Line/Data Line Coupling Network for 100kHz and 1MHz Damped Oscillator Tests per IEC 61000-4-18, 50 V / 4 A CNV 504N5.3 4-wire Signal Line/Data Line Coupling Network for 100kHz and 1MHz Damped Oscillator Tests per IEC 61000-4-18, 250 V / 4 A CNV 508N4 4-pair (8-wire) coupling network according to IEC 60255-26, 250 V / 4 A CNV 508N4.1 4-pair (8-wire) coupling network according to IEC 60255-26, 250 V / 16 A MS 100N Magnetic field coil, 1 mx 1 m Field strengths up to 1000 A/m iec.control Remote control and reporting software including standard test procedures and report generation. general data size and weight Single-phase 19''/6Hu, about 28kg; Three-phase 19''/6Hu, about 41kg supply voltage 115/230V+10/-15% fuse 2 x T 2 AT (230 V) ;2 x T 4 AT (115 V)