-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
OCS 500N6F Fast and slow damped oscillatory and ringing wave simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: OCS 500N6F Fast and slow damped oscillatory and ringing wave simulator
- Commodity ID: 1064529767752683520
- 品牌11: EMTEST
- 行业: 民用
- 描述: OCS 500N6F series simulators are capable of fast damped oscillatory wave testing with an oscillation frequency of 3 MHz / 10 MHz / 30 MHz and a test voltage up to 4.4 kV; it can also be extended to perform oscillations in accordance with the requirements
- 品牌: EM TEST
OCS 500N6F - Combined Fast/Slow Damped Oscillatory and Ringing Wave Test Set
OCS 500N6F series simulators are capable of fast damped oscillatory wave testing with an oscillation frequency of 3 MHz / 10 MHz / 30 MHz and a test voltage up to 4.4 kV; it can also be extended to perform oscillations in accordance with the requirements of the EN / IEC 61000-4-18 standard Frequency is 100 kHz / 1 MHz, slow damped oscillatory wave test with test voltage up to 3.0 kV; and ring wave test with test voltage up to 6.0 kV according to EN / IEC 61000-4-12 standard .
Damped oscillatory waves are repeatable transient phenomena that mainly occur on power lines, control lines, and signal lines installed in high-voltage and medium-voltage substations. They are divided into slow damped oscillatory waves and fast damped oscillatory waves. The ringing wave is a non-repetitive damped oscillatory transient phenomenon that occurs on low-voltage power lines, control lines, and signal lines in public and non-public power grids.
-
main feature:
Fully automatic integrated test system
Various pulse tests can be performed through a single DUT connection port
Fast damped oscillatory wave test voltage up to 4.4 kV
Slow damped oscillatory wave test voltage up to 3 kV (option)
Ring wave test voltage up to 6 kV (option)
Built-in coupling/decoupling network, single-phase and three-phase test voltage up to 32 A
Support front panel manual operation
USB and GPIB interface
Standards compliant:
ANSI/IEEE C37.90
ANSI/IEEE C62.41
IN 61000-4-10
IN 61000-4-12
IN 61000-4-18
IEC 60255-22-1
IEC 60255-26
IEC 61000-4-10
IEC 61000-4-12
IEC 61000-4-18
IEC 61000-6-5
IEC 61850-3
IEC 62052-11
advantage:
OCS 500N6F Series - 3-in-1 Combined Damped Shockwave and Ringwave Simulator
The basic configuration of the OCS 500N6F series is a fast damped oscillatory wave simulator complying with the IEC 61000-4-18 standard, the test voltage can reach 4.4 kV, and the oscillation frequencies are 3 MHz, 10 MHz and 30 MHz respectively. Different models of the OCS 500N6F series have built-in single-phase or three-phase coupling/decoupling networks respectively, and the rated current of each line is 16A or 32A.
Optional modules:
- The slow damped oscillatory wave module has a test voltage up to 3kV and an oscillation frequency of 100 kHz / 1 MHz. It complies with EN/IEC 61000-4-18 standard and meets the requirements of ANSI/IEEE C39.70 standard for testing protective relays.
- The test voltage of the ring wave module can reach 6 kV, which meets the requirements of IEC 61000-4-12 and ANSI/IEEE C62.41 standards.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.

Accessory equipment:
CNV 504N5 - Signal/Data Line Coupling/Decoupling Networks
CNV 504N5 is a 4-wire coupling/decoupling network for coupling a slow damped oscillatory waveform with a frequency of 100 kHz or 1 MHz to signal/data lines in accordance with EN/IEC 61000-4-18 .
appendix:
MS 100N - Magnetic field coil for damped oscillating magnetic field testing
The MS 100N is a 1 m * 1 m magnetic field coil that complies with the requirements of the EN / IEC 61000-4-10 standard. The field coil is fixed on a movable, height-adjustable, and 360-degree rotatable stand.
Connect the MS 100N directly to the corresponding high voltage output port of the OCS 500N6F to generate a damped oscillating magnetic field that complies with the requirements of the EN / IEC 61000-4-10 standard, up to test level 5.
-
Specific indicators:
OCS 500N6F Series OCS 500N6F Model OCS500N6F Built-in single-phase coupling and decoupling network
AC 250V/16A; DC 250V/16AOCS500N6F.1 Built-in single-phase coupling and decoupling network
AC 250V/32A; DC 250V/32AOCS500N6F.2 Built-in three-phase coupling and decoupling network
AC 3×440V/16A; DC 250V/16AOCS500N6F.3 Built-in three-phase coupling and decoupling network
AC 3×440V/32A; DC 250V/32ARCCB test corresponds to OCS 500N6F model OCS500N6F.4 Built-in coupling and decoupling network
AC3×440V/32A, DC250V/32A,
calibrated according to IEC 61008-1 and IEC 61009-1Ring wave test in compliance with IEC61000-4-12 and ANSI/IEEC62.41 standards open circuit voltage 250V—6000V+/-10% Rise Time 0.5us+/-30% Oscillation frequency 100kHz+/-10% decay rate Peak 2-Peak 1=0.4-1.1
Peak 3-Peak 2=0.4-0.8
Peak 4-Peak 3=0.4-0.8source impedance 12 ohms and 30 ohms +/- 20% Short circuit peak current 500A max at 12 ohms
200A max at 30 ohms (internal)Rise Time <1us Oscillation frequency 100kHz+/-10% polarity positive/negative repetition rate 1 / min or faster Fast damped oscillatory wave test according to IEC61000-4-18 standard High voltage output open circuit voltage 450V—4400V+/-10% Rise Time 5ns+/-30% Oscillation frequency 3MHz、10MHz、30MHz+/-10% attenuation Peak 5 > 50% of peak 1
Peak 10 < 50% of peak 1source impedance 50 ohms +/-20% Coupling method common mode polarity positive/negative repetition rate Up to 5,000 / s ± 10% Pulse duration 50 ms ± 20% at 3 MHz
15 ms ± 20% at
10 MHz 5 ms ± 20% at 30 MHzburst period 300 ms ± 20% short circuit current 9 A - 88 A ± 20% Current waveform rise time < 330 ns at 3 MHz
< 100 ns at 10 MHz
< 33 ns at 30 MHzdecay (current) Peak 5 > 25% of Peak 1
Peak 10 < 25% of Peak 1Slow damped shock wave test according to IEC61000-4-18 standard (option) High voltage output open circuit voltage 250V—3000V+/-10% Open circuit voltage at the output of the coupling network 250V—2500V+/-10% Rise Time 75ns+/-20% Oscillation frequency 100kHz and 1MHz+/-10% attenuation Peak 5 > 50% of peak 1
Peak 10 < 50% of peak 1source impedance 200 ohms +/-20% polarity positive/negative repetition rate At 100kHz, up to 50/s; at 1MHz, up to 500/s Pulse duration at least 2s Ring wave waveform according to EN / IEC 61000-4-12 and ANSI / IEE C62.41 (option) open circuit voltage 250V—6000V+/-10% Rise Time 0.5us+/-30% Oscillation frequency 100kHz+/-10% attenuation Peak 2 - Peak 1: 0.4 - 1.1
Peak 3 - Peak 2: 0.4 - 0.8
Peak 4 - Peak 3: 0.4 - 0.8source impedance 12 ohms and 30 ohms ± 20% Short circuit peak current Internal: 500 A max at 12 ohm or 200 A max at 30 ohm Rise Time 0.2 us to 1.0 us Oscillation frequency 100kHz+/-10% polarity positive/negative repetition rate 1 / min or faster trigger circuit release pulse automatic, manual, external Synchronize 0°-360°, resolution 1° CRO trigger Oscilloscope 5 V trigger signal output direct output Via High Voltage Safety Lab Connectors Coupling method line-line; line-ground OCS500N6F AC: 250V/16A, 50/60Hz
DC: 250V/16AOCS500N6F.1 AC: 250V/32A, 50/60Hz
DC: 250V/32AOCS500N6F.2 AC: 3×440V/16A, 50/60Hz
DC: 250V/16AOCS500N6F.3 AC: 3×440V/32A, 50/60Hz
DC: 250V/32AOCS500N6F.4 AC: 3×440V/32A, 50/60Hz
DC: 250V/32AMeasurement ringing wave LCD display peak voltage and peak current test program Quick start test program Instant start, simple and fast Standard Test Procedure Compliant with IEC 61000-4-18
Compliant with IEC61000-4-12 Test Level 1-4
Manual Test Standard Test Procedure
Compliant with ANSI/IEEC62.41
Compliant with IEC61000-4-10 Test Level 1-5User-Defined Test Program Change the polarity after N pulses
Change the coupling mode after N pulses
Change the voltage after N pulses
Change the phase angle after N pulsesinterface serial interface Optical link, 3 m cable, USB Type A connector parallel interface IEEE488, address 1-30 option CNV 504N5.1 4-wire Signal Line/Data Line Coupling Network for 100kHz and 1MHz Damped Oscillator Tests per IEC 61000-4-18, 50 V / 4 A CNV 504N5.3 4-wire Signal Line/Data Line Coupling Network for 100kHz and 1MHz Damped Oscillator Tests per IEC 61000-4-18, 250 V / 4 A CNV 508N4 4-pair (8-wire) coupling network according to IEC 60255-26, 250 V / 4 A CNV 508N4.1 4-pair (8-wire) coupling network according to IEC 60255-26, 250 V / 16 A MS 100N Field coils to EN/IEC 61000-4-10 iec.control Remote control and reporting software including standard test procedures and report generation. CA OCS F Kit
Load resistor assembly KW0R1 for fast damped oscillation waveform verification is 0.1 ohm load resistor
KW1000 is 1000ohm load resistor
CA MC F adapter is used to match KW 0R1 and KW 1000 to the power supply output port of OCS 500N6FS-DOW/N6F 100kHz and 1MHz Slow Damped Oscillator Expansion Module, Compliant with IEC 61000-4-18 RWG/N6F 6kV ring wave extension module, compliant with IEC 61000-4-12 and ANSI/IEEE
C62.41general data size and weight Single-phase 19''/9Hu, about 32kg;
Three-phase 19''/9Hu, about 50kgsupply voltage 115/230V+10/-15% fuse 2 x T 2 AT (230 V) ;2 x T 4 AT (115 V)