- Commodity name: NETWAVE Three-Phase Series Multifunctional Programmable AC and DC Power Quality Immunity Simulator
- Commodity ID: 1064528482240450560
- 品牌11: EMTEST
- 行业: 军品,民用,汽车电子和整车
- 描述: The NetWave 3-Phase Series as a 3-Phase AC Power Quality Immunity Simulator is specifically designed to comply with IEC / EN 61000-4-13, -4-14, -4-27 (pre-compliant) and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/E
- 品牌: EM TEST
NetWave - Simulation of various power phenomena
The NetWave 3-Phase Series as a 3-Phase AC Power Quality Immunity Simulator is specifically designed to comply with IEC / EN 61000-4-13, -4-14, -4-27 (pre-compliant) and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/EN 61000-4-17 standard for DC ripple voltage testing and the IEC/EN 61000-4-29 standard for DC power supply voltage dips and short interruptions test requirements.
The NetWave family is suitable for inverters (eg solar inverters, wind inverters) and electric vehicle testing. In addition, the NetWave 3-phase series can meet aviation standards RTCA / DO 160 D/ E / F / G, Airbus ABD0100 and Boeing and military standards MIL-STD-704 A/ B / C / D / E / F, GJB181, GJB181 A/B requirements.
The NetWave 3-phase series can also be equipped with a power recovery module (option) for absorbing feedback power (AC/DC) up to NetWave nominal power.
-
main feature:
Wide range frequency range DC - 5 kHz
Output power up to 270 kVA AC / 324 kW DC
Output voltage up to 3 x 690 V AC (pn), ±1120 V DC
Can withstand large energy surge current
Power recovery can reach the nominal power (option)
Built-in arbitrary waveform generator for easy simulation of complex waveforms
Standard test procedures meet IEC / EN standards, aviation standards and MIL-STD military standard test requirements
Various interfaces
Standards compliant:
AIRBUS
AIRBUS, BOEING
BMW GS 95023
BOEING
DO 160 Section 16
DO 160 Section 16, Section 18
DO 160 Section 18
IEC/EN 61000-3-11
IEC/EN 61000-3-12
IEC/EN 61000-3-2
IEC/EN 61000-3-2, -3-12
IEC/EN 61000-3-3
IEC/EN 61000-3-3, -3-11
IEC/EN 61000-4-11, -4-29, -4-34
IEC 61000-4-11
IEC 61000-4-13
IEC 61000-4-14
IEC 61000-4-17
IEC 61000-4-27
IEC 61000-4-28
IEC 61000-4-29
IEC 61000-4-34
HE C 61000-3-2
LV 123
MBN LV 123
MIL STD 461
MIL STD 461 E CS 101
MIL STD 461 F CS 101
MIL STD 461 G CS 101
MIL-STD-704
PSA B21 7110
VW 80300
VW 80303
advantage:
NetWave - Powerful and versatile AC/DC power simulator
NetWave is a programmable three-phase AC and DC power supply with a wide frequency range and the ability to generate various waveforms to meet the needs of various test applications in the field of electromagnetic compatibility and aerospace. NetWave is not only based on real-time processor technology, but also equipped with a built-in high-performance PC, digital signal processor (DSP) and hard disk to generate and record waveforms in real time.
Measurements of harmonics and flicker require a pure sinusoidal voltage as required by the standard. NetWave output voltage distortion is guaranteed to be less than 0.1%, regardless of load conditions. Editing waveforms with NetWave can be done by editing waveform segments, or by editing test points (which will usually generate megabytes of data).
NetWave supports many common interface types, such as GPIB, Ethernet interface.
A Complete Solution for High Voltage Component Testing
With NetWave, for the first time, high voltage components up to 1120vdc can be inspected according to LV 123, VW 80300 and other automotive standards. Tests include fast and slow voltage changes and voltage ripple testing.
Additional Low Frequency Amplifier Amplifier 200Nx Use CN 200Nx to couple voltage ripple up to 450 kHz to the power line.
Using a closed-loop control approach, the network control software measures the voltage ripple and continuously controls its magnitude.

controlling software:
netwave.control (hereinafter referred to as nc) - editing, text and management software for waveform and standard tests
nc is a handy tool for easily manipulating NewWave. Users can use nc to edit various waveforms composed of waveform fragments or test points, and download them to NetWave. According to different needs, users can adjust the waveform with advanced image tools. nc provides users with a variety of preset waveform segments and a large number of standard test procedures in line with electromagnetic compatibility and aerospace standards. In addition, nc also supports any waveform recorded by other means, such as a waveform intercepted from an oscilloscope, or a waveform imported from an Excel or CSV file, etc. All types of waveforms can be downloaded to NetWave.
nc also has a powerful reporting function that can generate test or measurement reports and supports Windows 2000, Windows XP, Windows Vista, Windows 7 and Windows 8 operating systems.

-
Specific indicators:
THREE PHASE NETWAVE MODELS NETWAVE 20 / 20.X Three Phase Multifunction AC/DC Power Quality Immunity Simulator
22,500 VA AC/27,000 W DC
Cabinet with CastersNetWave 30 / 30.x Three-phase multifunctional AC/DC power quality immunity simulator
30,000 VA AC/36,000 W DC
Cabinet with castersNetWave 67.x Three-phase multifunctional AC/DC power quality immunity simulator
67,000 VA AC/72,000 W DC
Cabinet with optional castersNetWave 90.x Three Phase Multifunction AC/DC Power Quality Immunity Simulator
90,000 VA AC/108,000 W DC
Cabinet Without CastersNetWave 108.x 108 kVA AC / 150 kW DC, fixed position technical details NETWAVE 20 The output voltage 0V - 3x300V AC (p-n)
0V - +/- 425V DCOutput current 26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 20.2 The output voltage 0V - 3x360V AC (pn)
0V - 3 x 620V AC (pp)
0V - +/- 500V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 20.3 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1120V DC
Insulation voltage 560 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 20.5 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1000V DC
Insulation voltage 1000 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 30 The output voltage 0V - 3x300V AC (p-n)
0V - +/- 425V DCOutput current 33A (RMS) continuous
66A (RMS) short-term (max. 3s)
250A repeatable peak currentNETWAVE 30.2 The output voltage 0V - 3x360V AC (pn)
0V - 3 x 620V AC (pp)
0V - +/- 500V DCOutput current
(at AC voltage up to 300 V)33A (RMS) continuous
66A (RMS) short-term (max. 3s)
250A repeatable peak currentNETWAVE 30.3 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1120V DC
Insulation voltage 560 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)33A (RMS) continuous
66A (RMS) short-term (max. 3s)
250A repeatable peak currentNETWAVE 30.5 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1000V DC
Insulation voltage 1000 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)33A (RMS) continuous
66A (RMS) short-term (max. 3s)
250A repeatable peak currentNETWAVE 60 The output voltage 0V - 3x300V AC (p-n)
0V - +/- 425V DCOutput current 66A (RMS) continuous
100A (RMS) short-term (max. 3s)
400A repeatable peak currentNETWAVE 60.2 The output voltage 0V - 3x360V AC (pn)
0V - 3 x 620V AC (pp)
0V - +/- 500V DCOutput current
(at AC voltage up to 300 V)66A (RMS) continuous
100A (RMS) short-term (max. 3s)
400A repeatable peak currentNETWAVE 67.3 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1120V DC
Insulation voltage 560 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)75A (RMS) continuous
100A (RMS) short-time (max. 3s)
400A repeatable peak currentNETWAVE 67.5 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1000V DC
Insulation voltage 1000 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)75A (RMS) continuous
100A (RMS) short-time (max. 3s)
400A repeatable peak currentNETWAVE 90.2 The output voltage 0V - 3x360V AC (pn)
0V - 3 x 620V AC (pp)
0V - +/- 500V DCOutput current
(at AC voltage up to 300 V)100A (RMS) continuous
150A (RMS) short-term (max. 3s)
500A repeatable peak currentNETWAVE 90.3 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1120V DC
Insulation voltage 560 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)100A (RMS) continuous
150A (RMS) short-term (max. 3s)
500A repeatable peak currentNETWAVE 90.5 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1000V DC
Insulation voltage 1000 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 360 V)100A (RMS) continuous
150A (RMS) short-term (max. 3s)
500A repeatable peak currentNETWAVE 108.3 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1120V DC
Insulation voltage 560 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 500 V)100A (RMS) continuous
150A (RMS) short-term (max. 3s)
500A repeatable peak currentNETWAVE 108.5 The output voltage 0V - 3x400V AC (pn)
0 V - 3 x 690 V AC (pp)
0V - +/- 1000V DC
Insulation voltage 1000 V DCOutput current
(at AC voltage up to 300 V, DC voltage up to 500 V)100A (RMS) continuous
150A (RMS) short-term (max. 3s)
500A repeatable peak currentNETWAVE Scalable Testing Capabilities simple mode Control via MatLab to
integrate NetWave into existing automated test environmentsAC source mode PLL synchronization with other voltage sources trigger Extensible trigger functions Fragment "Leap" Increment/decrement of voltage and/or frequency in continuous time windows external mode Control NetWave via external control signal General Data (All Models) Output frequency DC - 5,000Hz Frequency Accuracy Stability 100ppm Phase Accuracy Resolution 1° output noise < 50 V : 110 mV rms ;> 50 V : 320 mV rms conversion rate 8 V / us Output insulation voltage x.5 Models: 1000 VDC Line-Ground
All Other Models: 600 VDC Line-Groundoutput connector Safety Lab Connector CEE Type 32 A Connector (NetWave 20.x and NetWave 30.x only) interface GPIB
Ethernet interface
RS 232 (connected to DPA analyzer)
Frame bus (internal system bus)General data voltage detection internal or external, 4 wire Distortion rate (THD) < 0.5%, @ 50 / 60 Hz Output Voltage Stability Better than 0.1% Output Voltage Accuracy Better than
DC: +-0.2 % of set value +-0.15 % of full scale,
AC: add +-0.1 % of set frequency/1000Maximum Voltage Compensation 5% of nominal voltage current limiter 5A - Maximum current (peak), stop/continue (behavior) Protect Overcurrent, overvoltage, overheating, undervoltage Triggering and DUT monitoring
trigger 2 inputs, 2 outputs Device under test monitoring 2 inputs, configurable waveform generator DC waveform DC, Ramp, Square, Triangle, Sawtooth, Step, Sine, Sine sweep, Sine ramp, Damped sinewave, Sine ripple, Profile, Square sweep, Noise, Sine Dwell, Sinc, Harmonic, Exponent ... AC waveform Sine, Modulation, Sine sweep, Sweep on Sine, Sine up/down, Sine unbalance, Overswing, Sine offset, Sine Dip, Harmonic, Interharmonic, Interharmonic step, Harmonicdistortion ... Display and Control show 2 lines LCD, 40 characters per line LED indicator Respectively display: power on, output channel, trigger, hard disk function status operate 6 function keys, start test key, power key size NetWave 20.x Approx. 1785 x 930 x 755 mm
Approx. 1785 x 1210 x 755 mm
(with power recovery hardware module)NetWave 30.x Approx. 1785 x 930 x 755 mm
Approx. 1785 x 1210 x 755 mm
(with power recovery hardware module)NetWave 67.x Approx. 2080 x 1205 x 970 mm
Approx. 2080 x 1615 x 970 mm
(with power recovery hardware module)NetWave 90.2 Approx. 2080 x 1810 x 970 mm
Approx. 2080 x 2410 x 970 mm
(with power recovery hardware module)NetWave 90.3 approx. 2080 x 2410 x 970 mm NetWave 108.3 approx. 2080 x 2410 x 970 mm weight NetWave 20.x Approx. 740 kg
Approx. 810 kg (with power recovery hardware module)NetWave 30.x Approx. 740 kg
Approx. 810 kg (with power recovery hardware module)NetWave 67.x Approx. 1,180 kg
Approx. 1,380 kg (with power recovery hardware module)NetWave 90.2 Approx. 1,700 kg
Approx. 2,000 kg (with power recovery hardware module)NetWave 90.3 approx. 2,000 kg (recovery) NetWave 108.3 approx. 2,000 kg (recovery) power supply supply voltage 3 x 400 V (3P, PE)
or optionally 3 x 480 V (3P, PE)Input Current 50 A / 90 A (NetWave 20 / 20.x)*
70 A / 140 A (NetWave 30 / 30.x)*
160 A / 212 A (NetWave 60 / 60.x)*
210 A / 318 A (NetWave 90.2 )*
* Higher current value for 3 s short-time currentpower frequency 45Hz - 65Hz Connector screw terminal option NW-BOARD measurement module aisle Built-in 6-channel (three-phase) measurement board
3 voltage measurement channels
3 current measurement channelsvoltage range 25V, 50V, 100V, 250V, 550V
unipolar or bipolarcurrent range 10A, 25A, 50A, 100A, 220A
unipolar or bipolarresolution 16 bit Accuracy Voltage: Better than +-0.05 % of reading +-0.2 % of range
Current: Better than +-0.2 % of reading +-0.3 % of rangeFrequency Range DC - 100 kHz Sampling Rate 5 Hz - 200 kHz, selectable data storage Hard disk space minimum 40 GB
file maximum 1 GBPC requirements Minimum Intel i5 with 8 GB RAM or similar Measure Parallel Mode NetWave 20.x ;NetWave 30.x Parallel mode hardware (parallel mode options 20/30, 67, 90, 108) parallel mode In parallel mode, all three built-in sources will be used in parallel.
A separate interface terminal is provided for single-phase output for the connection of the EUT.
In parallel mode, the three-phase interface terminals will be disconnected from the internal power supply.NetWave 20.x 78 A (RMS) continuous
short-term (up to 3 s) 141 A (RMS)
repeatable peak 600 ANetWave 30.x 99 A (rms) continuous short-term
(up to 3 s) 198 A (rms)
repeatable peak 500 ANetWave 67.x 225 A (RMS) continuous
short-term (up to 3 s) 300 A (RMS)
repeatable peak 600 ANetWave 90.x 300 A (rms) continuous short-term
(up to 3 s) 450 A (rms)
repeatable peak 700 ANetWave 108.x 300 A (rms) continuous short-term
(up to 3 s) 450 A (rms)
repeatable peak 1000 APower recovery (requires optional power recovery module 20 / 30, 67, 90, 108) voltage 400 V +/- 10% (45 Hz - 65 Hz) recoverable power Returnable to nominal AC/DC power for this NetWave model Power Restoration Module 20/30 For NetWave 20/20.x
up to 22.5 kVA AC/27 kW DC
26 A (rms) continuous
short (up to 3 s) 47 A (rms)
repeatable peak 200 APower Restoration Module 20/30 For NetWave 30 / 30.x
up to 30 kVA AC / 36 kW DC
33 A (rms) continuous
short (up to 3 s) 66 A (rms)
repetitive peak 250 APower Restoration Module 67 For NetWave 67/67.x
up to 67 kVA AC/72 kW DC
75 A (rms) continuous
short (up to 3 s) 100 A (rms)
repetitive peak 400 APower Recovery Module 90 For NetWave 90.2
Up to 90 kVA AC/108 kW DC
100 A (RMS) Continuous
Short (up to 3 s) 150 A (RMS)
Repeatable Peak 500 APower Recovery Module 108 For NetWave 108.3
Up to 108 kVA AC/132 kW DC
100 A (RMS) Continuous
Short (up to 3 s) 150 A (RMS)
Repeatable Peak 500 Apower factor > 0.92 at full load DC Extended Voltage Range OPT-3 DC-EVR Dual DC voltage range, using virtual dual phase, only valid for 3 phase NetWaves NetWave 20, 30, 67, 90, 108 Extends to 425 VDC to 850 VDC NetWave x.2 models Scalable to 500 VDC to 1000 VDC NetWave x.3 models Extended to 560 VDC to 1120 VDC included Filter box F-BOX 3-60
application Low pass filter for smooth DC voltage ≤ 500 mV required for very low ripple applications standard MIL-HDBK-704-7 HDC 103
MIL-HDBK-704-8 LDC 103
Other applications with low ripple signalMIL-HDBK application Test Condition A (10 Hz); Test Condition B (25 Hz) Voltage AC: 230 V; DC: 500 V electric current 60 A frequency up to 60 Hz size 200 mm x 150 mm x 60 mm weight 1.65 kg Filter box F-BOX 3-100 application Low pass filter for smooth DC voltage ≤ 500 mV required for very low ripple applications standard MIL-HDBK-704-7 HDC 103
MIL-HDBK-704-8 LDC 103
Other applications with low ripple signalMIL-HDBK application Test Condition A (10 Hz); Test Condition B (25 Hz) Voltage AC: 230 V; DC: 500 V electric current 100 A frequency up to 60 Hz size 255 mm x 180 mm x 80 mm weight 3.25 kg Filter box L-BOX 1-32A application 50 µH decoupling coil with integrated 10 µF capacitor
per MIL-STD-704 LDCMaximum EUT voltage 500 VDC / 360 VAC Maximum EUT current 32 A Filter box L-BOX 1-100A application 50 µH decoupling coil with integrated 10 µF capacitor
per MIL-STD-704 LDCMaximum EUT voltage 500 VDC / 360 VAC Maximum EUT current 100 A other models NetWave Single Phase Series Single-phase multifunctional power quality immunity simulator up to 7,500 VA AC and 9,000 W DC