Wisdom

Product


EMC Testing Solution Provider


NETWAVE Three-Phase Series Multifunctional Programmable AC and DC Power Quality Immunity Simulator

Brand:

EM TEST

NETWAVE Three-Phase Series Multifunctional Programmable AC and DC Power Quality Immunity Simulator
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: NETWAVE Three-Phase Series Multifunctional Programmable AC and DC Power Quality Immunity Simulator
    • Commodity ID: 1064528482240450560
    • 品牌11: EMTEST
    • 行业: 军品,民用,汽车电子和整车
    • 描述: The NetWave 3-Phase Series as a 3-Phase AC Power Quality Immunity Simulator is specifically designed to comply with IEC / EN 61000-4-13, -4-14, -4-27 (pre-compliant) and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/E
    • 品牌: EM TEST

    NetWave - Simulation of various power phenomena

    The NetWave 3-Phase Series as a 3-Phase AC Power Quality Immunity Simulator is specifically designed to comply with IEC / EN 61000-4-13, -4-14, -4-27 (pre-compliant) and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/EN 61000-4-17 standard for DC ripple voltage testing and the IEC/EN 61000-4-29 standard for DC power supply voltage dips and short interruptions test requirements.

    The NetWave family is suitable for inverters (eg solar inverters, wind inverters) and electric vehicle testing. In addition, the NetWave 3-phase series can meet aviation standards RTCA / DO 160 D/ E / F / G, Airbus ABD0100 and Boeing and military standards MIL-STD-704 A/ B / C / D / E / F, GJB181, GJB181 A/B requirements.

    The NetWave 3-phase series can also be equipped with a power recovery module (option) for absorbing feedback power (AC/DC) up to NetWave nominal power.

  • main feature:

      Wide range frequency range DC - 5 kHz

      Output power up to 270 kVA AC / 324 kW DC

      Output voltage up to 3 x 690 V AC (pn), ±1120 V DC

      Can withstand large energy surge current

      Power recovery can reach the nominal power (option)

      Built-in arbitrary waveform generator for easy simulation of complex waveforms

      Standard test procedures meet IEC / EN standards, aviation standards and MIL-STD military standard test requirements

      Various interfaces

    Standards compliant:

      AIRBUS

      AIRBUS, BOEING

      BMW GS 95023

      BOEING

      DO 160 Section 16

      DO 160 Section 16, Section 18

      DO 160 Section 18

      IEC/EN 61000-3-11

      IEC/EN 61000-3-12

      IEC/EN 61000-3-2

      IEC/EN 61000-3-2, -3-12

      IEC/EN 61000-3-3

      IEC/EN 61000-3-3, -3-11

      IEC/EN 61000-4-11, -4-29, -4-34

      IEC 61000-4-11

      IEC 61000-4-13

      IEC 61000-4-14

      IEC 61000-4-17

      IEC 61000-4-27

      IEC 61000-4-28

      IEC 61000-4-29

      IEC 61000-4-34

      HE C 61000-3-2

      LV 123

      MBN LV 123

      MIL STD 461

      MIL STD 461 E CS 101

      MIL STD 461 F CS 101

      MIL STD 461 G CS 101

      MIL-STD-704

      PSA B21 7110

      VW 80300

      VW 80303

    advantage:

      NetWave - Powerful and versatile AC/DC power simulator

      NetWave is a programmable three-phase AC and DC power supply with a wide frequency range and the ability to generate various waveforms to meet the needs of various test applications in the field of electromagnetic compatibility and aerospace. NetWave is not only based on real-time processor technology, but also equipped with a built-in high-performance PC, digital signal processor (DSP) and hard disk to generate and record waveforms in real time.

      Measurements of harmonics and flicker require a pure sinusoidal voltage as required by the standard. NetWave output voltage distortion is guaranteed to be less than 0.1%, regardless of load conditions. Editing waveforms with NetWave can be done by editing waveform segments, or by editing test points (which will usually generate megabytes of data).

      NetWave supports many common interface types, such as GPIB, Ethernet interface.

      A Complete Solution for High Voltage Component Testing

      With NetWave, for the first time, high voltage components up to 1120vdc can be inspected according to LV 123, VW 80300 and other automotive standards. Tests include fast and slow voltage changes and voltage ripple testing.

      Additional Low Frequency Amplifier Amplifier 200Nx Use CN 200Nx to couple voltage ripple up to 450 kHz to the power line.

      Using a closed-loop control approach, the network control software measures the voltage ripple and continuously controls its magnitude.

      

    software

     

    controlling software:

      netwave.control (hereinafter referred to as nc) - editing, text and management software for waveform and standard tests

      nc is a handy tool for easily manipulating NewWave. Users can use nc to edit various waveforms composed of waveform fragments or test points, and download them to NetWave. According to different needs, users can adjust the waveform with advanced image tools. nc provides users with a variety of preset waveform segments and a large number of standard test procedures in line with electromagnetic compatibility and aerospace standards. In addition, nc also supports any waveform recorded by other means, such as a waveform intercepted from an oscilloscope, or a waveform imported from an Excel or CSV file, etc. All types of waveforms can be downloaded to NetWave.

      nc also has a powerful reporting function that can generate test or measurement reports and supports Windows 2000, Windows XP, Windows Vista, Windows 7 and Windows 8 operating systems.

      

    software

  • Specific indicators:

    THREE PHASE NETWAVE MODELS
    NETWAVE 20 / 20.X Three Phase Multifunction AC/DC Power Quality Immunity Simulator
    22,500 VA AC/27,000 W DC
    Cabinet with Casters
    NetWave 30 / 30.x Three-phase multifunctional AC/DC power quality immunity simulator
    30,000 VA AC/36,000 W DC
    Cabinet with casters
    NetWave 67.x Three-phase multifunctional AC/DC power quality immunity simulator
    67,000 VA AC/72,000 W DC
    Cabinet with optional casters
    NetWave 90.x Three Phase Multifunction AC/DC Power Quality Immunity Simulator
    90,000 VA AC/108,000 W DC
    Cabinet Without Casters
    NetWave 108.x 108 kVA AC / 150 kW DC, fixed position
    technical details
    NETWAVE 20
    The output voltage 0V - 3x300V AC (p-n)
    0V - +/- 425V DC
    Output current 26A (RMS) continuous
    47A (RMS) short-time (max. 3s)
    200A repeatable peak current
    NETWAVE 20.2
    The output voltage 0V - 3x360V AC (pn)
    0V - 3 x 620V AC (pp)
    0V - +/- 500V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    26A (RMS) continuous
    47A (RMS) short-time (max. 3s)
    200A repeatable peak current
    NETWAVE 20.3
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1120V DC
    Insulation voltage 560 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    26A (RMS) continuous
    47A (RMS) short-time (max. 3s)
    200A repeatable peak current
    NETWAVE 20.5
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1000V DC
    Insulation voltage 1000 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    26A (RMS) continuous
    47A (RMS) short-time (max. 3s)
    200A repeatable peak current
    NETWAVE 30
    The output voltage 0V - 3x300V AC (p-n)
    0V - +/- 425V DC
    Output current 33A (RMS) continuous
    66A (RMS) short-term (max. 3s)
    250A repeatable peak current
    NETWAVE 30.2
    The output voltage 0V - 3x360V AC (pn)
    0V - 3 x 620V AC (pp)
    0V - +/- 500V DC
    Output current
    (at AC voltage up to 300 V)
    33A (RMS) continuous
    66A (RMS) short-term (max. 3s)
    250A repeatable peak current
    NETWAVE 30.3
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1120V DC
    Insulation voltage 560 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    33A (RMS) continuous
    66A (RMS) short-term (max. 3s)
    250A repeatable peak current
    NETWAVE 30.5
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1000V DC
    Insulation voltage 1000 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    33A (RMS) continuous
    66A (RMS) short-term (max. 3s)
    250A repeatable peak current
    NETWAVE 60
    The output voltage 0V - 3x300V AC (p-n)
    0V - +/- 425V DC
    Output current 66A (RMS) continuous
    100A (RMS) short-term (max. 3s)
    400A repeatable peak current
    NETWAVE 60.2
    The output voltage 0V - 3x360V AC (pn)
    0V - 3 x 620V AC (pp)
    0V - +/- 500V DC
    Output current
    (at AC voltage up to 300 V)
    66A (RMS) continuous
    100A (RMS) short-term (max. 3s)
    400A repeatable peak current
    NETWAVE 67.3
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1120V DC
    Insulation voltage 560 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    75A (RMS) continuous
    100A (RMS) short-time (max. 3s)
    400A repeatable peak current
    NETWAVE 67.5
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1000V DC
    Insulation voltage 1000 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    75A (RMS) continuous
    100A (RMS) short-time (max. 3s)
    400A repeatable peak current
    NETWAVE 90.2
    The output voltage 0V - 3x360V AC (pn)
    0V - 3 x 620V AC (pp)
    0V - +/- 500V DC
    Output current
    (at AC voltage up to 300 V)
    100A (RMS) continuous
    150A (RMS) short-term (max. 3s)
    500A repeatable peak current
    NETWAVE 90.3
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1120V DC
    Insulation voltage 560 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    100A (RMS) continuous
    150A (RMS) short-term (max. 3s)
    500A repeatable peak current
    NETWAVE 90.5
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1000V DC
    Insulation voltage 1000 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 360 V)
    100A (RMS) continuous
    150A (RMS) short-term (max. 3s)
    500A repeatable peak current
    NETWAVE 108.3
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1120V DC
    Insulation voltage 560 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 500 V)
    100A (RMS) continuous
    150A (RMS) short-term (max. 3s)
    500A repeatable peak current
    NETWAVE 108.5
    The output voltage 0V - 3x400V AC (pn)
    0 V - 3 x 690 V AC (pp)
    0V - +/- 1000V DC
    Insulation voltage 1000 V DC
    Output current
    (at AC voltage up to 300 V, DC voltage up to 500 V)
    100A (RMS) continuous
    150A (RMS) short-term (max. 3s)
    500A repeatable peak current
    NETWAVE Scalable Testing Capabilities
    simple mode Control via MatLab to
    integrate NetWave into existing automated test environments
    AC source mode PLL synchronization with other voltage sources
    trigger Extensible trigger functions
    Fragment "Leap" Increment/decrement of voltage and/or frequency in continuous time windows
    external mode Control NetWave via external control signal
    General Data (All Models)
    Output frequency DC - 5,000Hz
    Frequency Accuracy Stability 100ppm
    Phase Accuracy Resolution 1°
    output noise < 50 V : 110 mV rms ;> 50 V : 320 mV rms
    conversion rate 8 V / us
    Output insulation voltage x.5 Models: 1000 VDC Line-Ground
    All Other Models: 600 VDC Line-Ground
    output connector Safety Lab Connector CEE Type 32 A Connector (NetWave 20.x and NetWave 30.x only)
    interface GPIB
    Ethernet interface
    RS 232 (connected to DPA analyzer)
    Frame bus (internal system bus)
    General data
    voltage detection internal or external, 4 wire
    Distortion rate (THD) < 0.5%, @ 50 / 60 Hz
    Output Voltage Stability Better than 0.1%
    Output Voltage Accuracy Better than
    DC: +-0.2 % of set value +-0.15 % of full scale,
    AC: add +-0.1 % of set frequency/1000
    Maximum Voltage Compensation 5% of nominal voltage
    current limiter 5A - Maximum current (peak), stop/continue (behavior)
    Protect Overcurrent, overvoltage, overheating, undervoltage

    Triggering and DUT monitoring

    trigger 2 inputs, 2 outputs
    Device under test monitoring 2 inputs, configurable
    waveform generator
    DC waveform DC, Ramp, Square, Triangle, Sawtooth, Step, Sine, Sine sweep, Sine ramp, Damped sinewave, Sine ripple, Profile, Square sweep, Noise, Sine Dwell, Sinc, Harmonic, Exponent ...
    AC waveform Sine, Modulation, Sine sweep, Sweep on Sine, Sine up/down, Sine unbalance, Overswing, Sine offset, Sine Dip, Harmonic, Interharmonic, Interharmonic step, Harmonicdistortion ...
    Display and Control
    show 2 lines LCD, 40 characters per line
    LED indicator Respectively display: power on, output channel, trigger, hard disk function status
    operate 6 function keys, start test key, power key
    size
    NetWave 20.x Approx. 1785 x 930 x 755 mm
    Approx. 1785 x 1210 x 755 mm
    (with power recovery hardware module)
    NetWave 30.x Approx. 1785 x 930 x 755 mm
    Approx. 1785 x 1210 x 755 mm
    (with power recovery hardware module)
    NetWave 67.x Approx. 2080 x 1205 x 970 mm
    Approx. 2080 x 1615 x 970 mm
    (with power recovery hardware module)
    NetWave 90.2 Approx. 2080 x 1810 x 970 mm
    Approx. 2080 x 2410 x 970 mm
    (with power recovery hardware module)
    NetWave 90.3 approx. 2080 x 2410 x 970 mm
    NetWave 108.3 approx. 2080 x 2410 x 970 mm
    weight
    NetWave 20.x Approx. 740 kg
    Approx. 810 kg (with power recovery hardware module)
    NetWave 30.x Approx. 740 kg
    Approx. 810 kg (with power recovery hardware module)
    NetWave 67.x Approx. 1,180 kg
    Approx. 1,380 kg (with power recovery hardware module)
    NetWave 90.2 Approx. 1,700 kg
    Approx. 2,000 kg (with power recovery hardware module)
    NetWave 90.3 approx. 2,000 kg (recovery)
    NetWave 108.3 approx. 2,000 kg (recovery)
    power supply
    supply voltage 3 x 400 V (3P, PE)
    or optionally 3 x 480 V (3P, PE)
    Input Current 50 A / 90 A (NetWave 20 / 20.x)*
    70 A / 140 A (NetWave 30 / 30.x)*
    160 A / 212 A (NetWave 60 / 60.x)*
    210 A / 318 A (NetWave 90.2 )*
    * Higher current value for 3 s short-time current
    power frequency 45Hz - 65Hz
    Connector screw terminal
    option
    NW-BOARD measurement module
    aisle Built-in 6-channel (three-phase) measurement board
    3 voltage measurement channels
    3 current measurement channels
    voltage range 25V, 50V, 100V, 250V, 550V
    unipolar or bipolar
    current range 10A, 25A, 50A, 100A, 220A
    unipolar or bipolar
    resolution 16 bit
    Accuracy Voltage: Better than +-0.05 % of reading +-0.2 % of range
    Current: Better than +-0.2 % of reading +-0.3 % of range
    Frequency Range DC - 100 kHz
    Sampling Rate 5 Hz - 200 kHz, selectable
    data storage Hard disk space minimum 40 GB
    file maximum 1 GB
    PC requirements Minimum Intel i5 with 8 GB RAM or similar
    Measure Parallel Mode NetWave 20.x ;NetWave 30.x
    Parallel mode hardware (parallel mode options 20/30, 67, 90, 108)
    parallel mode In parallel mode, all three built-in sources will be used in parallel.
    A separate interface terminal is provided for single-phase output for the connection of the EUT.
    In parallel mode, the three-phase interface terminals will be disconnected from the internal power supply.
    NetWave 20.x 78 A (RMS) continuous
    short-term (up to 3 s) 141 A (RMS)
    repeatable peak 600 A
    NetWave 30.x 99 A (rms) continuous short-term
    (up to 3 s) 198 A (rms)
    repeatable peak 500 A
    NetWave 67.x 225 A (RMS) continuous
    short-term (up to 3 s) 300 A (RMS)
    repeatable peak 600 A
    NetWave 90.x 300 A (rms) continuous short-term
    (up to 3 s) 450 A (rms)
    repeatable peak 700 A
    NetWave 108.x 300 A (rms) continuous short-term
    (up to 3 s) 450 A (rms)
    repeatable peak 1000 A
    Power recovery (requires optional power recovery module 20 / 30, 67, 90, 108)
    voltage 400 V +/- 10% (45 Hz - 65 Hz)
    recoverable power Returnable to nominal AC/DC power for this NetWave model
    Power Restoration Module 20/30 For NetWave 20/20.x
    up to 22.5 kVA AC/27 kW DC
    26 A (rms) continuous
    short (up to 3 s) 47 A (rms)
    repeatable peak 200 A
    Power Restoration Module 20/30 For NetWave 30 / 30.x
    up to 30 kVA AC / 36 kW DC
    33 A (rms) continuous
    short (up to 3 s) 66 A (rms)
    repetitive peak 250 A
    Power Restoration Module 67 For NetWave 67/67.x
    up to 67 kVA AC/72 kW DC
    75 A (rms) continuous
    short (up to 3 s) 100 A (rms)
    repetitive peak 400 A
    Power Recovery Module 90 For NetWave 90.2
    Up to 90 kVA AC/108 kW DC
    100 A (RMS) Continuous
    Short (up to 3 s) 150 A (RMS)
    Repeatable Peak 500 A
    Power Recovery Module 108 For NetWave 108.3
    Up to 108 kVA AC/132 kW DC
    100 A (RMS) Continuous
    Short (up to 3 s) 150 A (RMS)
    Repeatable Peak 500 A
    power factor > 0.92 at full load
    DC Extended Voltage Range
    OPT-3 DC-EVR Dual DC voltage range, using virtual dual phase, only valid for 3 phase NetWaves
    NetWave 20, 30, 67, 90, 108 Extends to 425 VDC to 850 VDC
    NetWave x.2 models Scalable to 500 VDC to 1000 VDC
    NetWave x.3 models Extended to 560 VDC to 1120 VDC included

    Filter box F-BOX 3-60

    application Low pass filter for smooth DC voltage ≤ 500 mV required for very low ripple applications
    standard MIL-HDBK-704-7 HDC 103
    MIL-HDBK-704-8 LDC 103
    Other applications with low ripple signal
    MIL-HDBK application Test Condition A (10 Hz); Test Condition B (25 Hz)
    Voltage AC: 230 V; DC: 500 V
    electric current 60 A
    frequency up to 60 Hz
    size 200 mm x 150 mm x 60 mm
    weight 1.65 kg
    Filter box F-BOX 3-100
    application Low pass filter for smooth DC voltage ≤ 500 mV required for very low ripple applications
    standard MIL-HDBK-704-7 HDC 103
    MIL-HDBK-704-8 LDC 103
    Other applications with low ripple signal
    MIL-HDBK application Test Condition A (10 Hz); Test Condition B (25 Hz)
    Voltage AC: 230 V; DC: 500 V
    electric current 100 A
    frequency up to 60 Hz
    size 255 mm x 180 mm x 80 mm
    weight 3.25 kg
    Filter box L-BOX 1-32A
    application 50 µH decoupling coil with integrated 10 µF capacitor
    per MIL-STD-704 LDC
    Maximum EUT voltage 500 VDC / 360 VAC
    Maximum EUT current 32 A
    Filter box L-BOX 1-100A
    application 50 µH decoupling coil with integrated 10 µF capacitor
    per MIL-STD-704 LDC
    Maximum EUT voltage 500 VDC / 360 VAC
    Maximum EUT current 100 A
    other models
    NetWave Single Phase Series Single-phase multifunctional power quality immunity simulator up to 7,500 VA AC and 9,000 W DC
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ