EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
NETWAVE Single Phase Power Quality Immunity Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: NETWAVE Single Phase Power Quality Immunity Simulator
- Commodity ID: 1064527177505722368
- 品牌11: EMTEST
- 行业: 军品,民用,汽车电子和整车
- 描述: The NetWave Three-Phase Series is specially designed as a three-phase AC power quality immunity simulator in accordance with IEC/EN 61000-4-13, -4-14, and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/EN 61000-4-17 st
- 品牌: EM TEST
NetWave - Simulation of various power phenomena
The NetWave Three-Phase Series is specially designed as a three-phase AC power quality immunity simulator in accordance with IEC/EN 61000-4-13, -4-14, and -4-28 standards. As a DC power quality immunity simulator, it can also meet the IEC/EN 61000-4-17 standard for DC ripple voltage testing and the IEC/EN 61000-4-29 standard for DC power supply voltage dips and short interruptions test requirements.
NetWave's low distortion and high stability guarantee full compliance with IEC/EN 61000-3-2, -3-3, -3-11 and -3-12 and JIS C 61000- 3-2 Standard requirements for harmonic and flicker tests. The NetWave family is also suitable for inverters (eg solar inverters, wind inverters) and electric vehicle testing.
In addition, the NetWave single-phase series can meet the requirements of aviation standards DO-160, Airbus ABD0100 and Boeing and military standards MIL-STD-704.
-
main feature:
Wide range frequency range DC - 5 kHz
Output power up to 7,500 VA AC / 9,000 W DC
Output voltage up to 360 V AC / +/- 500 V DC
The maximum surge current that can withstand is 200 A
Extensible triggering and control capabilities (NetWave 7.3)
Built-in arbitrary waveform generator for easy simulation of complex waveforms
Standard test procedures meet IEC / EN standards, aviation standards and MIL-STD military standard test requirements
Built-in voltmeter and ammeter (option)
Various interfaces
Standards compliant:
AIRBUS
BOEING
DO 160 Section 16
IN 61000-3-11
IN 61000-3-12
EN 61000-3-2
EN 61000-3-3
IN 61000-4-11
IN 61000-4-13
IN 61000-4-14
IN 61000-4-17
IN 61000-4-28
IN 61000-4-29
IEC 61000-3-11
IEC 61000-3-12 Ed.2:2011
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-4-11
IEC 61000-4-13
IEC 61000-4-14
IEC 61000-4-17
IEC 61000-4-28
IEC 61000-4-29
HE C 61000-3-2
MIL STD 461 D CS 101
MIL STD 461 E CS 101
MIL STD 461 G CS 101
MIL-STD-704
advantage:
NetWave - Powerful and versatile AC/DC power simulator
NetWave is a programmable three-phase AC and DC power supply with a wide frequency range and the ability to generate various waveforms to meet the needs of various test applications in the field of electromagnetic compatibility and aerospace. NetWave is not only based on real-time processor technology, but also equipped with a built-in high-performance PC, digital signal processor (DSP) and hard disk to generate and record waveforms in real time.
NetWave has low distortion rate and high stability. Even if the power supply load changes, it can still ensure full compliance with IEC/EN 61000-3-2, JIS C 61000-3-2 and IEC/EN 61000-3-3 and IEC/ Requirements for harmonics and flicker measurements according to EN 61000-3-11 and IEC/EN 61000-3-12 standards. The NetWave series is also suitable for inverter (e.g. solar inverter, wind inverter) and electric vehicle testing. In addition, the NetWave single-phase series can meet the requirements of aviation standards DO-160, Airbus ABD0100 and Boeing, as well as military standard MIL-STD-704.
Measurements of harmonics and flicker require a pure sinusoidal voltage as required by the standard. NetWave output voltage distortion is guaranteed to be less than 0.1%, regardless of load conditions. Use NetWave to edit waveforms, either by editing waveform fragments or by editing test points (usually generating megabytes of data), and can easily record waveform files up to 1GByte. The measurement channels support peak voltages up to +/- 500 V and peak currents up to +/- 150 A with 16-bit resolution.
NetWave supports several common interface types such as GPIB, Ethernet and USB (for connecting memory sticks).
controlling software:
netwave.control (hereinafter referred to as nc) - editing, text and management software for waveform and standard tests
nc is a convenient tool for easily controlling NewWave. Users can use nc to edit various waveforms composed of waveform fragments or test points, and download them to NetWave. According to different needs, users can use advanced picture tools to adjust the waveform. nc provides users with a variety of preset waveform segments and a large number of standard test procedures in line with electromagnetic compatibility and aerospace standards. In addition, nc also supports any waveform recorded by other methods, such as waveforms intercepted from an oscilloscope, or imported from Excel or CSV files. All types of waveforms can be downloaded to NetWave.
nc also has a powerful reporting function that can generate test or measurement reports and supports Windows 2000, Windows XP, Windows Vista, Windows 7 and Windows 8 operating systems.

-
Specific indicators:
SINGLE PHASE NETWAVE MODELS NETWAVE 3.1 Versatile AC/DC Power Supply, 3 kVA AC/4,250 W DC, Compliant with EN / IEC 61000-4-x Series Standards NetWave 7 Multifunctional AC/DC power supply, 7.5 kVA AC/9,000 W DC, complies with EN / IEC 61000-4-x series standards NetWave 7.3 Versatile AC/DC power supply, 7.5 kVA AC/9,000 W DC, complies with EN / IEC 61000-4-x series standards, with built-in isolation transformer for aerospace standards (DO-160, Airbus and Boeing) and military standards (MIL -STD-704) required tests technical details NETWAVE 3.1 The output voltage 0V - 310V AC (RMS)
0V - +/- 440V DCOutput current 10A (RMS) continuous
20A (RMS) short-time (max. 3s)
70A repeatable peak currentNETWAVE 7 The output voltage 0V - 300V AC (RMS)
0V - +/- 425V DCOutput current
(at AC voltage up to 300 V,
DC 360 V)26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 7.3 The output voltage 0V - 360V AC (RMS)
0V - +/- 500V DCOutput current
(at AC voltage up to 300 V,
DC voltage up to 360 V)26A (RMS) continuous
47A (RMS) short-time (max. 3s)
200A repeatable peak currentNETWAVE 7.3 Extensible Testing Capabilities AC power mode PPL phase-locked loop synchronization with other voltage sources trigger Extensible trigger functions Fragment "Leap" Voltage and/or Frequency Increment/Decrement in Continuous Time Window external mode Control NetWave via external control signal simple mode Control via MatLab to integrate NetWave into existing automated test environments General Data (All Models) Output frequency DC - 5,000Hz Frequency Accuracy Stability 100ppm Phase Accuracy Resolution 1° output noise < 320 mV rms conversion rate 8 V / us
AC signal superimposed on DC bias voltageThrough a linear load, < 20 mV interface GPIB
Ethernet interface
RS 232 (connected to DPA analyzer)
Frame bus (internal system bus)General data voltage detection internal or external, 4 wire Distortion rate (THD) < 0.5%, @ 50 / 60 Hz Output Voltage Stability Better than 0.1% Output Voltage Accuracy Better than 0.5% Maximum Voltage Compensation 5% of nominal voltage current limiter When Frequency < 75 Hz, 2 A - Maximum Current (NetWave 3)
When Frequency < 75 Hz, 5 A - Maximum Current (NetWave 7.x)
Stop/Current LimiterProtect Overcurrent, overvoltage, overheating, undervoltage Triggering and DUT monitoring trigger 2 inputs, 2 outputs Device under test monitoring 2 inputs, configurable waveform generator DC waveform DC, Ramp, Square, Triangle, Sawtooth, Step, Sine, Sine sweep, Sine ramp, Damped sinewave, Sine ripple, Profile, Square sweep, Noise, Sine Dwell, Sinc, Harmonic, Exponent ... AC waveform Sine, Modulation, Sine sweep, Sweep on Sine, Sine up/down, Overswing, Sine offset, Sine Dip, Sine switching, Harmonic, Interharmonic, Interharmonic step, Harmonic distortion ... output output connector 4 mm safety lab connector.
EUT adapter with connector (depending on country of use)Display and Control show 2 lines LCD, 40 characters per line LED indicator Respectively display: power on, output channel, trigger, hard disk function status operate 6 function keys, start test key, power key powered by supply voltage 3 x 400 V (3P, N, PE)
3 x 480 V (3P, N, PE)
3 x 208 V (3P, N, PE)
NetWave 7 requires optional MT-Netwave,
NetWave 7.x requires no optionInput Current 32 A (Line 16 A, Neutral 27 A) power frequency 45Hz - 65Hz Connector CEE style 32 A connector size and weight NETWAVE 3.1 19" / 9HU ,417 mm x 449 mm x 500 mm ,45 kg NetWave 7 NetWave 7.3 Small Cabinet, 25HU, 600 mm x 800 mm x 1,250 mm
120 kgoption OPTIONAL ACCESSORIES (ONLY FOR NETWAVE 7) MT-Netwave Three-phase matching transformer
input voltage 3 x 200 V
output voltage 3 x 400 V
independent chassisIT-NetWave Three-phase isolation transformer
Input voltage 3 x 200 V or 3 x 400 V
Output voltage 3 x 400 V
with 25 HU cabinet (including space for a DPA 500N)NW-BOARD measurement module voltage range 25V, 50V, 100V, 250V, 500V unipolar or bipolar current range 7 A, 15 A, 30 A, 70 A and 150 A, unipolar or bipolar resolution 16 bit Accuracy Voltage: better than 0.2%; current: better than 0.5% Frequency Range DC - 50 kHz Sampling Rate 5 Hz - 100 kHz, selectable data storage The minimum hard disk space is 40 GB, and the maximum file size is 1 GB PC requirements Minimum Intel i5 with 8 GB RAM or similar Filter box F-BOX 1 application Low pass filter for smooth DC voltage ≤ 500 mV required for very low ripple applications standard MIL-HDBK-704-7 HDC 103
MIL-HDBK-704-8 LDC 103
Other applications with low ripple signalMIL-HDBK application Test Condition A (10 Hz); Test Condition B (25 Hz) Voltage AC: 230 V; DC: 500 V electric current 32 A frequency up to 60 Hz size 190 x 72 x 110 mm, plug + 24 mm weight 0.83 kg Filter box L-BOX 1-32A application 50 µH decoupling coil with integrated 10 µF capacitor
per MIL-STD-704 LDCMaximum EUT voltage 500 VDC / 360 VAC Maximum EUT current 32 A Filter box L-BOX 1-100A application 50 µH decoupling coil with integrated 10 µF capacitor
per MIL-STD-704 LDCMaximum EUT voltage 500 VDC / 360 VAC Maximum EUT current 100 A other models NetWave Three Phase Series Three-phase multifunctional AC/DC power quality immunity simulator up to 108,000 VA AC and 150,000 W DC