EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
EFT 500N5 Series Electrical Fast Transient Burst Simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: EFT 500N5 Series Electrical Fast Transient Burst Simulator
- Commodity ID: 1064522182249041920
- 品牌11: EMTEST
- 行业: 民用
- 描述: The EFT 500N5 Series is state-of-the-art EFT/Burst test equipment with built-in coupling/decoupling networks for single-phase or three-phase power supply systems and high voltage terminals for connection to capacitive coupling clamps. Spike frequencies ra
- 品牌: EM TEST
The EFT 500N5 Series is state-of-the-art EFT/Burst test equipment with built-in coupling/decoupling networks for single-phase or three-phase power supply systems and high voltage terminals for connection to capacitive coupling clamps. Spike frequencies range from 100 Hz to 1,000 kHz.
The EFT 500N5 can generate 10,000 transients per second, or 1,000 transients per burst. Its performance fully meets the requirements of IEC 61000-4-4:2012 (Ed.3). Pre-programmed standard test routines and several optional user test routines make the EFT 500N5 the best discrete test equipment for testing products under test or semi-assembled products during final test.
-
main feature:
The lightest combo simulator with a 7" touchscreen
Built-in burst test module (5.5 kV), surge test module (5.0 kV) and voltage drop test module
Built-in single-phase coupling/decoupling network up to 400 V / 32 A
Front panel manual operation, simple and convenient
The start button and stop button have LED indicators to show the test status
With peak voltage and peak current monitoring output port
With fiber optic interface and Ethernet interface for remote control
Can control external three-phase coupling network
Voltage drop test module complies with IEC / EN 61000-4-8 / -11 / -29 standards (DC)
With failure detection function
Standards compliant:
ANSI/IEEE C62.41
EN 61000-4-4
EN 61000-6-1
EN 61000-6-2
IEC 60601-1-2
IEC 61000-4-4
IEC 61326
IEC 61850-3
advantage:
EFT 500N5 - Electrical Fast Transient Burst Test Equipment Beyond Standard Requirements
As we all know, EFT 500N5's peak pulse frequency and burst duration can be adjusted in a wide range, and can meet the coaxial 50 ohm load output waveform and the common mode operation of the DUT port at the same time. The EFT 500N5 is a true fully compliant EFT/Burst test device.
EFT 500N5 has a variety of models, through the built-in single-phase or three-phase coupling network, it can meet the test of the equipment under test with a rated current up to 50 A. EFT 500N5 can also be integrated into a complete test system, and connected to a common coupling/decoupling network through the relevant control interface, so as to cooperate with other EM TEST 500 series products.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
appendix:
ITP - Immunity Test Probe Assembly
ITP is a product development diagnostic test tool. It includes a variety of near-field probes that can locate weak points in a system or on a printed circuit board. A burst simulator is used to generate interference signals.
CA EFT kit - Electrical Fast Transient/Burst Calibration Kit
According to the requirements of the IEC 61000-4-4 Ed.2 standard, the characteristics of the burst generator are verified by two different loads of 50 ohm and 1,000 ohm. EM TEST provides users with calibration components including these two load resistors and an adapter to verify the output port of the device under test.
HFK - Capacitive coupling clamp
HFK capacitive coupling clamps fully meet the requirements of the IEC / EN 61000-4-4 standard.
-
Specific indicators:
EFT 500N model EFT 500N5.1 Built-in three-phase coupling network,
AC: 3x 440V/32A
DC: 270 V / 32 AEFT 500N5.2 Built-in three-phase coupling network,
AC: 3x 440V/50A
DC: 270 V / 50 AEFT 500N5.5 Built-in single-phase coupling network,
AC: 250V/32A
DC: 270 V / 32 AEFT 500N5.8 Built-in three-phase coupling network,
AC: 3x 690V/32A
DC: 270 V / 32 Atest level voltage range 200V - 4,800V 50 ohm load 100V - 2,400V Pulse waveform 50ohm load rise time tr 5ns ± 30% Pulse width td 50ns ± 30% Pulse waveform 1,000ohm load rise time tr 5ns ± 30% Pulse width td 35ns - 150ns source impedance 50 ohm ± 20% polarity positive/negative trigger release burst Automatic, manual, external start Burst Width Td = 0.1ms - 999.9ms Burst repetition rate Tr = 10ms - 9,999ms pulse repetition rate f = 0.1kHz - 1,000kHz test duration T = 0:01 min - 99:59 min
T > 99:59 min - infiniteoutput direct output Via high voltage coaxial connector Coupling method L, N, PE and various combinations DUT AC power supply 50/60Hz Single phase: 250 V / 32 A
Three phase: 3 x 440 V / 32 A or 50 ADUT DC power supply 270 V / 32 A or 50 A DUT power supply Other DUT supply voltage can be customized CRO trigger Oscilloscope 15V trigger signal
pulse group duration and pulse frequency can be checkedtest program Quick Start Instant start, simple and fast user testing program - User-Defined Test Program
- Change the voltage after T time
- Change frequency after T time
- Frequency sweep within monoburst
- T Time enough to change burst width
- Random burst output
- Synchronized burst output
- T Time enough to change polarity
Standard Test Procedure - Complies with IEC 61000-4-4 standard test level
- Automatic Test Level X - Y
Serve Service, Setup, Self-Test interface serial interface USB parallel interface IEEE 488, addresses 1 - 30 Coupled network interface Control external coupling network CNI 503 general data size and weight EFT 500N5.1: 19"/6HU, 22kg
EFT 500N5.2: 19"/6HU, 40kg
EFT 500N5.5: 19"/3HU, 20kg
EFT 500N5.8: 19"/3HU, 23kgsupply voltage 115/230V, +10/-15% fuse 2 x T 2AT (230V); 2 x T 4AT (115V) Environmental requirements temperature 10 °C -35 °C Relative humidity 25 % - 75 %, non-condensing atmospheric pressure 86 kPa - 106 kPa option HFC Capacitive coupling clamp according to IEC 61000-4-4 KW 50 50 ohm matching resistors for waveform verification KW 1000 1000 ohm matched resistors for waveform verification CA EFT kit Burst calibration kit including KW50, KW1000, DUT port adapter and carrying case CA HFC kit Capacitive coupling clamp calibration adapter kit, consisting of
- sensor board: conforming to IEC / EN 61000-4-4 standard Ed 3.0
- support accessory: fixes the KW 50 adapter at the same
100 mm height as the capacitive coupling clampA6dB 6dB attenuator CNI 503 Three-phase coupling/decoupling network, 3x440V/32A-63A-100A iec.control remote control software Remote control and reporting software including standard test procedures and report generation.