EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
DPA 503N Three-phase Harmonic Flicker Analyzer
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: DPA 503N Three-phase Harmonic Flicker Analyzer
- Commodity ID: 1064521235707875328
- 品牌11: EMTEST
- 行业: 民用
- 描述: Harmonics and interharmonics are caused by modern electronic power conditioning modules, these non-linear modules used to control loads and reduce power consumption are the source of harmonic voltages in power supply systems. Variations in load current ca
- 品牌: EM TEST
DPA 503N - Fully Compatible Three-Phase Harmonic and Flicker Analyzer
Harmonics and interharmonics are caused by modern electronic power conditioning modules, these non-linear modules used to control loads and reduce power consumption are the source of harmonic voltages in power supply systems. Variations in load current cause voltage fluctuations, resulting in changes in the brightness and spectrum of the lighting system. Flicker refers to the visual discomfort caused by this light stimulus, and flicker needs to be limited to a minimum.
The DPA 503N Harmonic and Flicker Analyzer is suitable for three-phase EUT and also supports single-phase testing.
-
main feature:
Collect data in real time
Built-in hard disk to store data
16-bit A/D converter
6 input channels
Wide input current range up to 140 A rms
Wide input voltage range up to 530 V rms
High-end analysis function
USB interface for remote control and data transfer
Standards compliant:
IN 301489-1
IN 301489-17
IN 301489-24
IN 301489-7
EN 61000-3-2
EN 61000-3-3
IN 61000-4-15
IN 61000-4-7
EN 61000-6-1
EN 61000-6-2
IEC 60601-1-2
IEC 61000-3-11
IEC 61000-3-12 Ed.2:2011
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-4-15 Ed.2:2010
IEC 61000-4-7
IEC 61326
HE C 61000-3-2
advantage:
The DPA 503N is a fully certified harmonic and flicker analyzer that meets the latest version of IEC/EN61000-3-2, IEC/EN61000-3-3 and JIS C 61000-3-2 standards. Complies with both IEC/EN 61000-3-11 and IEC/EN 61000-3-12:2011 standards. DPA 503N has 6 independent input channels, of which 3 channels are used for voltage input and the other 3 channels are used for current input. It is designed and manufactured in full compliance with the design requirements of the IEC/EN 61000-4-7:2009 (applicable to Class A equipment) standard for harmonic analyzers and the design requirements of the IEC/EN 61000-4-15:2010 standard for scintillation meters. .
Based on real-time kernel technology and equipped with a built-in hard disk, DPA 503N can continuously record all measurement data. Via a digital PPL (Phase Locked Loop), the rectangular measurement window can be synchronized to every set of 10 or 12 cycles of the supply frequency (50 Hz or 60 Hz). Wide-range input current (maximum 140 A) avoids data loss caused by range switching.
Before, during or after the measurement, the measurement level can be selected at any time, and the AC voltage and current can be measured in real time.
controlling software:
dpa.control - Harmonics and flicker control and analysis software
dpa.control is a software tool for remote control of harmonic and flicker analysis systems. It can control all functions of the DPA 503N, upload measurement data records and carry out classification and analysis of the equipment under test.
dpa.control can not only perform data analysis according to the requirements of the latest version of the standard, but also perform data analysis according to the requirements of the old version of the standard. Its failure/pass judgment function can facilitate users to quickly judge the tested equipment; more detailed data can be used for further analysis and evaluation of the tested equipment.
dpa.control also has powerful text processing functions and can output directly to Word documents.
Accessory equipment:
ACS 503Nx Series - Three Phase AC Voltage Sources up to 90 kVA
The ACS 503Nx three-phase AC voltage source is capable of operating in accordance with IEC/EN 61000-3-2, IEC/EN 61000-3-3, JIS C 61000-3-2, IEC/EN 61000-3-11 and IEC/EN 61000-3 -12:2011 standard to provide pure AC supply voltage for harmonic and flicker analysis tests. It has a power rating of 90 kVA, an output voltage of up to 3 x 530 V, and a nominal current of up to 75 A (peak current up to 550 A per phase).
The ACS 503Nx AC voltage source can be controlled by dpa.control software.
AIF 503Nx Series - Flicker Impedance according to IEC / EN 61000-3-3 / -3-11
The AIF 503Nx series flicker impedance according to IEC / EN 61000-3-11 is suitable for flicker measurement of three-phase equipment under test up to a maximum current of 75 A. Two different impedance values can be set: reference impedance (0.24 ohm + j 0.15 ohm; 0.16 ohm + j 0.10 ohm) and test impedance (0.15 ohm + j 0.15 ohm; 0.10 ohm + j 0.10 ohm). For testing up to 16 A, the AIF 503N16 with phase impedance only can be used.
The AIF 503Nx Series flicker impedance is remotely controlled by the DPA 503N Harmonic and Flicker Analyzer.
-
Specific indicators:
measuring system input channel 6 (3 current input channels, 3 voltage input channels) Frequency Range 15Hz - 3,000Hz A/D converter 16 bits controller Built-in processor, Pentium 200MHz signal processor Motorola processor memory internal hard drive Instrument class Class I according to EN/IEC 61000-4-7 voltage input input range 10V - 530V rms overload Peak 4,000V precision Better than 0.4% of the measured value current input input range Depending on the type of current clamp used
, the standard current clamp can reach a maximum current of 140
AAccuracy (External Current Clamp) Compared with 16A, 2 turns is better than 0.8%; 5 turns is better than 0.6% general data supply voltage 85V - 255V,47Hz - 63Hz power 50 W max. size 19" / 3HU: 133 mm x 449 mm x 400 mm weight 12 kg temperature 0 °C - 40 °C Relative humidity 10% - 90%, non-condensing insulation Dielectric Strength 3 kV RMS interface USB interface for remote control and data transfer Harmonic Analysis standard test IEC / EN 61000-3-2 Ed.4
JIS C 61000-3-2 (2013)
IEC / EN 61000-3-12:2011design standards IEC/EN 61000-4-7 Ed.2.1 (2009) and
IEC/EN 61000-4-7 Ed.1 (1991)Harmonic range 1 - 50th harmonic group Test requirements for interharmonic waves according to EN/IEC 61000-4-7 (2009) Synchronize PLL (Phase Locked Loop), accuracy better than 0.005% Measurement window Rectangular window 8, 10, 12, 16 periods algorithm FFT smoothing filter First-order 1.5-second low-pass filter (on/off), selectable Anti-aliasing filter > 90dB test duration More than 30 hours, depending on hard disk storage space (about 1MB/min) show Vrms、Irms、Ipeak、Vpeak Harmonic display V, I, Phase, P, Q, S(2 - 50th harmonic) power information P, Q, S, power factor, THD(V), THD(I), crest factor(V), crest factor(I) flicker analysis standard test IEC / EN 61000-3-3 Ed.3 (2013)
IEC / EN 61000-3-11design standards EN/IEC 61000-4-15 (2010)
230V / 50Hz and 120V / 60HzBuilt-in flicker resistance Phase impedance: 0.24ohm + j0.15ohm;
Neutral impedance: 0.16ohm + j0.15ohmPst and Plt Accuracy Better than 5% dmax, dc, dt accuracy 0.15% flash data Pst and Plt, Vrms, dmax, dc, dt, P50%S, P10%S, P3%S, P1%S, P0.10% maximum value Pst、dmax、dc、dt observation period Optional, minimum 1 minute