Wisdom

Product


EMC Testing Solution Provider


DPA 500N Single Phase Harmonic Flicker Analyzer

Brand:

EM TEST

DPA 500N Single Phase Harmonic Flicker Analyzer
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: DPA 500N Single Phase Harmonic Flicker Analyzer
    • Commodity ID: 1064520403331469312
    • 品牌11: EMTEST
    • 描述: Harmonics and interharmonics are caused by modern electronic power conditioning modules, these non-linear modules used to control loads and reduce power consumption are the source of harmonic voltages in power supply systems. Variations in load current ca
    • 品牌: EM TEST

      DPA 500N - Fully Compatible Single Phase Harmonic and Flicker Analyzer

      Harmonics and interharmonics are caused by modern electronic power conditioning modules, these non-linear modules used to control loads and reduce power consumption are the source of harmonic voltages in power supply systems. Variations in load current cause voltage fluctuations, resulting in changes in the brightness and spectrum of the lighting system. Flicker refers to the visual discomfort caused by this light stimulus, and flicker needs to be limited to a minimum.

      The DPA 500N Harmonic and Flicker Analyzer is suitable for single-phase equipment under test.

  • main feature:

      Collect data in real time

      Built-in hard disk to store data

      16-bit A/D converter

      Wide input current range

      Wide input voltage range

      Built-in flicker resistance

      High-end analysis function

      USB interface for remote control and data transfer

    Standards compliant:

      IN 301489-1

      IN 301489-17

      IN 301489-24

      IN 301489-7

      EN 61000-3-2

      EN 61000-3-3

      IN 61000-4-15

      IN 61000-4-7

      EN 61000-6-1

      EN 61000-6-2

      IEC 60601-1-2

      IEC 61000-3-11

      IEC 61000-3-12 Ed.2:2011

      IEC 61000-3-2

      IEC 61000-3-3

      IEC 61000-4-15 Ed.2:2010

      IEC 61000-4-7

      IEC 61326

      HE C 61000-3-2

    advantage:

      DPA 500N is a fully certified harmonic and flicker analyzer that complies with the latest editions of IEC / EN 61000-3-2, IEC / EN 61000-3-3 and JIS C 61000-3-2. At the same time, it meets the requirements of IEC / EN 61000-4-7 Ed. 2.1:2009 (Class I instrument) and IEC / EN 61000-4-15:2010.

      Based on real-time kernel technology and equipped with a built-in hard disk, DPA 500N can continuously record all measurement data without gaps or overlaps. Via a digital PPL (Phase Locked Loop), a rectangular measurement window can be synchronized with each group (comprising 10 or 12 cycles) of the supply frequency (50 Hz or 60 Hz). Wide-range input current (up to 50 A) avoids data loss caused by range switching.

      The classification of the device under test can be selected at any time before or after the measurement. During the test, the output voltage and current value of the AC pure power supply can also be measured in real time. When making flicker measurements, the DPA 500N will automatically select the built-in flicker impedance, a feature that makes it a complete all-in-one harmonic flicker analyzer. With an external current clamp (option), the current range can be extended to 140 A rms or higher.

    controlling software:

      dpa.control - Harmonics and flicker control and analysis software

      dpa.control is a software tool for remote control of harmonic and flicker analysis systems. It can control all functions of the DPA 500N, upload measurement data records and carry out classification and analysis of the equipment under test.

      dpa.control can not only perform data analysis according to the requirements of the latest version of the standard, but also perform data analysis according to the requirements of the old version of the standard. Its failure/pass judgment function can facilitate users to quickly judge the equipment under test; more detailed data can be used for further analysis and evaluation of the equipment under test.

      dpa.control also has powerful text processing functions and can output directly to Word documents.

    Other models:

      DPA 500 Harmonic and Flicker Analysis Series

      EM TEST offers two different Harmonic and Flicker Analyzers to meet single phase (DPA 500N) and three phase (DPA 503N) application needs. The three-phase harmonic and flicker analyzer DPA 503N is also suitable for testing single-phase equipment under test.

    Accessory equipment:

      ACS 500N6 - 6 kVA Single Phase AC Voltage Source

      The ACS 500N6 single-phase AC voltage source is used to generate the pure AC supply voltage required for harmonic flicker analysis, fully meeting the standards of IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 requirements. Its rated power is 6 kVA and its output voltage can reach 300 V. The ACS 500N6 AC voltage source can be remotely controlled via the dpa.control software.

      ACS 500N3 - 3 kVA Single Phase AC Voltage Source

      The ACS 500N3 single-phase AC voltage source is used to generate the pure AC supply voltage required for harmonic flicker analysis, fully meeting the standards of IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 requirements. Its rated power is 3 kVA and its output voltage can reach 300 V. The ACS 500N3 AC voltage source can be remotely controlled via the dpa.control software.

  • Specific indicators:

    measuring system
    input channel 2 (1 current input channel, 1 voltage input channel)
    Frequency Range 15Hz - 3,000Hz
    A/D converter 16 bits
    controller Built-in processor, Pentium 200MHz
    signal processor Motorola processor
    memory internal hard drive
    Instrument class Class I according to EN/IEC 61000-4-7
    voltage input
    input range 10V - 530V rms
    overload Peak 4,000V
    precision Better than 0.4% of measured value; better than 0.1% of full scale
    current input
    Input range (built-in probe) Continuous 16A, short-time 50A
    Accuracy (built-in) Better than 0.4% of measured value; better than 0.05% relative to 16A
    Input range (external probe) Depends on the current clamp model used by the user, up to 140A
    Accuracy (External Current Clamp) Compared with 16A, 2 turns is better than 0.8%; 5 turns is better than 0.6%
    general data
    supply voltage 85V - 255V,47Hz - 63Hz
    power 50 W max.
    size 19" / 3HU: 133 mm x 449 mm x 500 mm
    weight 13 kg
    temperature 0 °C - 40 °C
    Relative humidity 10% - 90%, non-condensing
    insulation Dielectric Strength 3 kV RMS
    interface USB interface for remote control and data transfer
    Harmonic Analysis
    standard test EN/IEC 61000-3-2, JIS C 61000-3-2, EN/IEC 61000-3-12 External Current Clamp
    design standards IEC/EN 61000-4-7 Ed.2.1 (2009) and
    IEC/EN 61000-4-7 Ed.1 (1991)
    Harmonic range 1 - 50th harmonic
    group Test requirements for interharmonic waves according to EN/IEC 61000-4-7 (2002 & Am.1:2008)
    Synchronize PLL (Phase Locked Loop), accuracy better than 0.005%
    Measurement window Rectangular window 8, 10, 12, 16 periods
    algorithm FFT
    smoothing filter First-order 1.5-second low-pass filter (on/off), selectable
    Anti-aliasing filter > 90dB
    test duration More than 30 hours, depending on hard disk storage space (about 1MB/min)
    show Vrms、Irms、Ipeak、Vpeak
    Harmonic display V, I, Phase, P, Q, S(2 - 50th harmonic)
    power information P, Q, S, power factor, THD(V), THD(I), crest factor(V), crest factor(I)
    flicker analysis
    standard test EN/IEC 61000-3-3
    design standards EN/IEC 61000-4-15 (2010 & 2003) 230V / 50Hz and 120V / 60Hz
    Built-in flicker resistance Phase impedance: 0.24ohm + j0.15ohm;
    Neutral impedance: 0.16ohm + j0.15ohm
    Pst and Plt Accuracy Better than 5%
    dmax, dc, dt accuracy 0.15%
    flash data Pst and Plt, Vrms, dmax, dc, dt, P50%S, P10%S, P3%S, P1%S, P0.10%
    maximum value Pst、dmax、dc、dt
    observation period Optional, minimum 1 minute
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ