Wisdom

Product


EMC Testing Solution Provider


CWS 500N4 Common Mode Conducted Disturbance Simulator DC (0 HZ) - 165 kHz

Brand:

EMTEST

CWS 500N4 Common Mode Conducted Disturbance Simulator DC (0 HZ) - 165 kHz
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: CWS 500N4 Common Mode Conducted Disturbance Simulator DC (0 HZ) - 165 kHz
    • Commodity ID: 1064518422755954688
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: CWS 500N4 is the most advanced ultra-compact all-in-one 0 Hz (DC) - 165 kHz common mode conducted emission test solution.
    • 品牌: EMTEST

    CWS 500N4 is the most advanced ultra-compact all-in-one 0 Hz (DC) - 165 kHz common mode conducted emission test solution.

    According to the requirements of the IEC 61000-4-16 standard, the equipment can cover 4 test levels of continuous mode and short-term mode tests at DC, 162/3Hz, 50Hz and 60Hz frequency points, and can also perform 4 test levels of Sweep mode testing from 10 Hz to 165 kHz.

    In addition, CWS 500N4 also meets the testing requirements of TR 50579 standard and IEC 61000-4-19 standard Annex C (draft) on electric energy metering devices.

  • main feature:

      Ultra-compact Common Mode Conducted Emissions Test Set to IEC 61000-4-16

      Built-in low frequency signal generator and low frequency amplifier

      Sweep Mode Frequency Range 10 Hz - 165 kHz

      Built-in rectifier module for DC testing

      Test option for energy metering devices according to IEC 61000-4-19 Annex C (optional)

      Built-in voltmeter (rms value)

      Test frequencies are DC, 16 2 / 3 Hz, 50 Hz and 60 Hz in continuous mode and short-term mode

      USB interface

      Built-in semiconductor power switch

    Standards compliant:

      IN 61000-4-16

      IEC 60255-22-7

      IEC 60255-26

      IEC 60533

      IEC 61000-4-16

      IEC 61000-4-19, Annex C

      IEC 61326

      IEC 61543

      IEC 61850-3

      prTR 50579

    advantage:

      Integrated common mode conducted interference test equipment - easy, fast and reliable

      The CWS 500N4 contains all necessary components required to complete the full compliance testing required by the IEC 61000-4-16 standard, such as signal generators, low-frequency amplifiers, DC rectifier modules, semiconductor power switches and voltage and current rms measurement equipment.

      The CWS 500N4 generates a 30 V signal at all test frequencies (DC, 16 2/3 Hz, 50 Hz and 60 Hz) in continuous mode and operates in 15 Hz - 150 kHz sweep mode without any external voltage source. test.

      In conjunction with the MV 2606N2.2, a 300 V signal can be generated at the respective test frequency (DC, 50 Hz or 60 Hz, depending on the power line frequency) in short-time mode. In conjunction with the programmable AC voltage source ACS 500N2.3, tests can be performed at 16 2/3 Hz or a frequency different from the mains line frequency.

      Through GPIB and USB interface, remote control can be realized by test software icd.control. icd.control supports various test programs, can automatically generate test reports with all test data, and has various interrupt functions. In addition, users can also trigger a quick start test program through manual operation, allowing easy, effective and accurate testing without software control.

      The menu and function keys on the front panel allow users to quickly and accurately edit the test path. The pointer can quickly control all test parameters in the program path, thus ensuring the reliability of the test.

    software:

      icd.control - forms a complete low frequency test system

      icd.control meets the requirements of the IEC 61000-4-16 standard and supports the common mode conducted emission test in the frequency range of 0Hz - 150kHz. Through the standard library, various test levels and different test modes required by the standard can be easily, effectively and reliably set. The test report contains all test settings and test results.

    Other models:

      DC - 1GHz Continuous Wave Simulator

      Continuous wave simulation has a history of more than 90 years. The CWS 500N series products can not only cover most of the frequency ranges required for industrial test applications based on the IEC 61000-4-6 standard, but EM TEST can also provide special test solutions for low frequency ranges or high current injection, as well as for automotive, TEM cell and microwave test solutions for aerospace and military applications.

      The CWS 500N4 can meet the requirements of the IEC 61000-4-16 standard for low-frequency testing applications of electrical and electronic equipment with common mode interference applied to power lines, control, signal and AC ports.

  • Specific indicators:

    Tested according to IEC / EN 61000-4-16
    Output Characteristics in Continuous Mode
    test frequency DC,16 2/3 Hz,50 Hz 和 60 Hz
    signal level 0.1 - 35 V rms or dc  
    Test Level 1 1 V, continuous
    Test level 2 3 V, continuous
    Test level 3 10 V, continuous
    Test Level 4 30 V, continuous
    output impedance 50 ohm ± 10%
    Total Harmonic Distortion < 10% (sine wave)
    DC ripple < 5%
    Output Characteristics in Short-Time Mode
    test frequency DC,16 2/3 Hz,50 Hz 和 60 Hz
    signal level 1 - 330 V rms or dc  
    Test Level 1 10 V for 1 s
    Test level 2 30 V for 1 s
    Test level 3 100 V for 1 s
    Test Level 4 300 V for 1 s
    output impedance 50 ohm ± 10%
    Total Harmonic Distortion < 10% (sine wave)
    phase synchronization 0° ± 5%
    DC ripple < 5%
    fall/rise time Between 1 us - 5 us
    illustrate This test requires optional MV 2606N2.2, automatic voltage regulator or ACS 200N2.3, programmable AC voltage source  
    Output Characteristics at 15 HZ - 165 KHZ
    Frequency Range 10 Hz - 165 kHz
    signal level 0.1 - 35 V rms  
    Test Level 1 1 V - 0.1 V - 1 V
    Test level 2 3 V - 0.3 V - 3 V
    Test level 3 10V - 1V - 10V
    Test Level 4 30 V - 3 V - 30 V
    output impedance 50 ohm ± 10%
    Total Harmonic Distortion < 1% (sine wave)
    Measurement
    Voltage Internal RMS measurement
    test program
    Quick start test program Instant on for quick and easy discrete frequency testing  
    service program service, settings
    Testing of electrical energy metering devices according to TR-EN 50579
    Interference test according to TR-EN 50579 and IEC 61000-4-19 ANNEX C (optional)
    Test frequency 2 kHz - 150 kHz
    signal level Up to 150 kHz at a maximum current of 3 A  
    Output impedance 1.0 ohm (external decoupling impedance SH 1R)
    Total Harmonic Distortion < 5% at highest signal level
    Accuracy Better than ± 5%
    frequency step max 1 %
    general data
    interface  
    serial interface USB
    parallel interface IEEE 488, addresses 1 - 30
    Failure detection 1 BNC input, active low to terminate test
    Failure detection 2 BNC input;
    when the input is active low, the test will be suspended;
    when the input is active high, the test will continue.
    When the number of failure events reaches 10, the test is terminated.
    software
    icd.control Versatile, versatile remote control and reporting software. Built-in standard library makes test setup easy.
    general data
    size 19" / 6 HU (555 mm x 448 mm x 286 mm)  
    weight  30 kg
    supply voltage 115 V or 230 V +10/-15%, 50/60Hz
    input power Maximum 600 W
    power factor cos (phi) = 0.96 at maximum output power in accordance with IEC 555 standard
    fuse 2 x 6.3 AT (115 V) or 2 x 3.15 AT (230V)
    for AC source 2 x 10 AT
    cool down Active cooling, air cooling
    Environmental requirements
    temperature 10 °C -40 °C
    Relative humidity Maximum 85%, no condensation
    atmospheric pressure 86 kPa  - 106 kPa
    Options
    coupling network
    CN 16-L2/L4 2-wire/4-wire coupling network, switchable
    Maximum AC voltage of the device under test: 440 V, 16.7 Hz - 80 Hz
    Maximum DC voltage of the device under test: 125 V
    Maximum test signal voltage: 330 V AC/DC
    power consumption: 40 W maximum
    CN 16-L2.1 2-wire coupling network
    Maximum AC voltage of the equipment under test: 300 V, 16.7 Hz - 80 Hz
    Maximum DC voltage of the equipment under test: 220 V
    Maximum voltage of the test signal: 330 V AC/DC
    power consumption: Maximum 200 W, air-cooled, with overheating Protection function
    Power supply: 85 - 265 V AC, 50/60Hz, fuse 1 AT
    CN 16-L3 3-wire coupling network
    Maximum AC voltage of the equipment under test: 440 V, 16.7 Hz - 80 Hz
    Maximum DC voltage of the equipment under test: 125 V
    Maximum test signal voltage: 330 V AC/DC
    power consumption: 40 W maximum
    CN 16-L4/690V 4-wire coupling network
    Maximum AC voltage of the equipment under test: 3 x 690 V, 50 / 60 Hz
    Maximum DC voltage of the equipment under test: 125 V
    Maximum voltage of the test signal: 330 V AC/DC
    power consumption: maximum 40 W
    CN 16-L8 8-wire coupling network
    Maximum AC voltage of the equipment under test: 300 V, 16.7 Hz - 80 Hz
    Maximum DC voltage of the equipment under test: 160 V
    Maximum voltage of the test signal: 330 V AC/DC
    power consumption: 40 W maximum
    CDN 16-L2 2-wire coupling network, decoupling through isolation transformer
    Maximum voltage/current of EUT: 300 V / 16 A
    Maximum voltage of test signal: 330 V AC/DC
    CDN 16-L4/400V 4-wire coupling network, decoupling via isolation transformer
    Maximum voltage/current for EUT: 3 x 480 V / 16 A
    Maximum voltage for test signal: 330 V AC/DC
    CDN 16-T2 Communication line coupling network, 60 V DC, 2 A
    Maximum EUT voltage: 60 V DC
    Frequency range of EUT: depends on communication application
    Maximum test signal voltage: 330 V AC/DC
    CN 60255-22-7 4-wire coupling network according to IEC 60255-26 standard figs. A1, A2 and A3,
    previous IEC 60255-22-7 standard figs. 2, 3 and 4, with common mode coupling and differential mode coupling
    CN 61543 Coupling network according to IEC 61543 (100 ohm)
    exchange source
    ACS 500N2.3 AC power supply, 0 - 330 V (AC) / 2 kVA, 10 Hz - 80 Hz, galvanically isolated; powered
    by CWS 500N4 Control
    supply via serial interface: 230 V / 16 A, 50 / 60 Hz
    MV 2606N2.2 Automatic voltage regulator, 0 - 330 V (ac) / 2 kVA, 50 Hz / 60 Hz, galvanically isolated; controlled
    by CWS 500N4 via analog output 0 - 10 V analog signal;
    mains supply: 230 V / 9 A, 50 / 60Hz
    Expansion options for test applications according to IEC 61000-4-19
    ELM set Conforms to the test requirements of Annex C of IEC 61000-4-19 standard for electric energy metering devices, including:
    -SH ELM, 1R and 100R, shunt resistor box and decoupling impedance
    -Current meter ext., display digits 5 1/2 digits, 150 kHz,
    remote control by icd.control software via USB interface
    -USB remote control cable-SH ELM and energy meter connection cable assembly
    ELM-R set (upgrade) Conforms to the test requirements of Annex C of IEC 61000-4-19 standard for energy metering devices, including:
    -CWS 500N4 hardware upgrade and calibration service
    -SH ELM, 1R and 100R, shunt resistor box and decoupling impedance
    -Current meter ext., display Digits 5 1/2 digits, 150 kHz,
    remote control by icd.control software via USB interface
    - USB remote control cable - SH ELM to energy meter connection cable assembly

     

全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ