EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Rf power amplifier BLWA 0810_80MHz-1GHz
Brand:
BONN
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Rf power amplifier BLWA 0810_80MHz-1GHz
- Commodity ID: 1064743719505907712
- 品牌11: BONN
- 描述: Rf power amplifier BLWA 0810_80MHz-1GHz
- 品牌: BONN
model
Frequency Range
Output Power
(minimum linear/typical W)
gain
(min/type dB)
harmonic
2nd/3rd dBc
BLWA 0810-10
80MHz-1GHz
10/12
40 / 42 ±2
20/20
BLWA 0810-30
80MHz-1GHz
30/35
44.8 / 47 ±2
20/20
BLWA 0810-40
80MHz-1GHz
40/45
46 / 48 ±2
20 / 20
BLWA 0810-50
80MHz-1GHz
50/60
47 /50 ±3
20 / 20
BLWA 0810-100
80MHz-1GHz
100/120
50 / 52 ±2
20 / 20
BLWA 0810-125
80MHz-1GHz
125/140
50 / 52 ±2
25 / 25
BLWA 0810-150
80MHz-1GHz
150/160
51.8 / 54 ±2
25 / 25
BLWA 0810-250/150
80MHz-1GHz
80MHz-400MHz
250 / 280
54 / 56 ±2
20 / 20
400MHz-1GHz
150 / 160
51.8 / 54 ±2
20 / 20
BLWA 0810-250
80MHz-1GHz
250/300
54 / 56 ±2
25 / 20
BLWA 0810-400/250
80MHz-1GHz
80MHz-400MHz
400 / 440
56 / 58 ±2
25 / 20
400MHz-1GHz
250 / 300
54 / 56 ±2
25 / 25
BLWA 0810-400
80MHz-1GHz
400/450
56 / 58 ±2
20 / 20
BLWA 0810-500/200D
80MHz-1GHz
80MHz-400MHz
500 / 600
57 / 59 ±2
20 / 15
400MHz-1GHz
200 / 220
53 / 55 ±2
20 / 20
BLWA 0810-500/350D
80MHz-1GHz
80MHz-400MHz
500 / 600
57 / 59 ±2
20 / 15
400MHz-1GHz
350 / 400
55.4 / 58 ±2
20 / 20
BLWA 0810-500
80MHz-1GHz
500/600
57 / 59 ±2
20 / 20
BLWA 0810-750
80MHz-1GHz
750/800
58.8 / 61 ±2
20 / 20
BLWA 0810-750/400
80MHz-1GHz
80MHz-400MHz
750 / 850
58.8 / 61 ±2
20 / 20
400MHz-1GHz
400 / 500
56 / 58 ±2
20 / 20
BLWA 0810-750/500
80MHz-1GHz
80MHz-400MHz
750 / 850
58.8 / 61 ±2
20 / 20
400MHz-1GHz
500 / 600
57 / 59 ±2
20 / 20
BLWA 0810-1000/400
80MHz-1GHz
80MHz-200MHz
1000 / 1100
60 / 62 ±2
18 / 20
200MHz-1GHz
400 / 500
56 / 58 ±2
20 / 20
BLWA 0810-1000/500D
80MHz-1GHz
80MHz-400MHz
1000/1150
60 / 62 ±2
20/15
400MHz-1GHz
500/600
57 / 59 ±2
20/20
BLWA 0810-1000
80MHz-1GHz
1000/1200
60 / 62 ±2
20/20
BLWA 0810-1400/700
80MHz-1GHz
80MHz-400MHz
1400/1500
61.5 / 64 ±2
20/20
400MHz-1GHz
700/850
58.4/61±2
20/20
BLWA 0810-1500/700D
80MHz-1GHz
80MHz-400MHz
1500/1700
61.8 / 64 ±2
20 /15
400MHz-1GHz
700/850
58.4/61±2
20/20
BLWA 0810-1500/900
80MHz-1GHz
80MHz-400MHz
1500/1600
61.8 / 64 ±2
20/20
400MHz-1GHz
900/950
59.5 / 62 ±2
20/20
BLWA 0810-1500/1000D
80MHz-1GHz
80MHz-400MHz
1500/1700
61.8 / 64 ±2
20 /15
400MHz-1GHz
1000/1150
60 / 62 ±2
20/20
BLWA 0810-1500/1200
80MHz-1GHz
80MHz-400MHz
1500/1700
61.8 / 64 ±2
20/20
400MHz-1GHz
1200/1300
60 / 62 ±2
20/20
BLWA 0810-1500D
80MHz-1GHz
80MHz-400MHz
1500/1700
61.8 / 64 ±2
20 /15
400MHz-1GHz
1500/1700
61.8 / 64 ±2
20/20
BLWA 0810-1700/1350
80MHz-1GHz
80MHz-400MHz
1700/1850
62.3 / 65 ±2
20/20
400MHz-1GHz
1350/1500
61.3 / 64 ±2
20/20
BLWA 0810-2000/1000/700
80MHz-1GHz
80MHz-280MHz
2000/2200
63 / 65 ±2
20/20
280MHz-480MHz
1000/1150
60 / 62 ±2
20/20
480MHz-1GHz
700/750
58.4/61±2
20/20
BLWA 0810-2000/1000D
80MHz-1GHz
80MHz-400MHz
2000/2200
63 / 65 ±2
20 /15
400MHz-1GHz
1000/1150
60 / 62 ±2
20/20
BLWA 0810-2000/1500D
80MHz-1GHz
80MHz-400MHz
2000/2200
63 / 65 ±2
20 /15
400MHz-1GHz
1500/1700
61.8 / 64 ±2
20/20
BLWA 0810-2000/1500
80MHz-1GHz
80MHz-400MHz
2000/2200
63 / 65 ±2
20/20
400MHz-1GHz
1500/1700
61.8 / 64 ±2
20/20
BLWA 0810-2000
80MHz-1GHz
2000/2200
63 / 65 ±2
20/20
BLWA 0810-2500/1000
80MHz-1GHz
80MHz-400MHz
2500/2750
64 / 66 ±2
20/20
400MHz-1GHz
1000/1200
60 / 62 ±2
20/20
BLWA 0810-3000/2000D
80MHz-1GHz
80MHz-400MHz
3000/3500
64.8 / 67 ±2
20/20
400MHz-1GHz
2000/2200
63 / 65 ±2
20/20
BLWA 0810-5000/3000D
80MHz-1GHz
80MHz-400MHz
5000/5500
67 / 69 ±2
20/20
400MHz-1GHz
3000/3500
65 / 67 ±2
20/20
model
Frequency Range
Cable power
AND
Dimension(H, D)19" system
1 HU = 44.45 mm
weight
kg
BLWA 0810-10
80MHz-1GHz
150
2 HU, 430 mm
11
BLWA 0810-30
80MHz-1GHz
200
2 HU, 430 mm
11
BLWA 0810-40
80MHz-1GHz
300
2 HU, 430 mm
13
BLWA 0810-50
80MHz-1GHz
400
3 HU, 430 mm
20
BLWA 0810-100
80MHz-1GHz
900
3 HU, 630 mm
26
BLWA 0810-125
80MHz-1GHz
950
3 HU, 630 mm
25
BLWA 0810-150
80MHz-1GHz
1000
3 HU, 630 mm
25
BLWA 0810-250/150
80MHz-1GHz
1000
3 HU, 630 mm
25
BLWA 0810-250
80MHz-1GHz
2000
4 HU, 630 mm
38
BLWA 0810-400/250
80MHz-1GHz
2400
4 HU, 630 mm
39
BLWA 0810-400
80MHz-1GHz
3100
6 HU, 630 mm
73
BLWA 0810-500/200D
80MHz-1GHz
3300
9 HU, 630 mm
85
BLWA 0810-500/350D
80MHz-1GHz
3300
9 HU, 630 mm
95
BLWA 0810-500
80MHz-1GHz
4000
6 HU, 630 mm
70
BLWA 0810-750
80MHz-1GHz
7000
18 HU, 800 mm
250
BLWA 0810-750/400
80MHz-1GHz
4000
6 HU, 630 mm
70
BLWA 0810-750/500
80MHz-1GHz
4000
6 HU, 630 mm
70
BLWA 0810-1000/400
80MHz-1GHz
4000
6 HU, 630 mm
73
BLWA 0810-1000/500D
80MHz-1GHz
9000
21 HU, 800 mm
220
BLWA 0810-1000
80MHz-1GHz
8500
15 HU, 800 mm
180
BLWA 0810-1400/700
80MHz-1GHz
10500
15 HU, 800 mm
190
BLWA 0810-1500/700D
80MHz-1GHz
11000
24 HU, 800 mm
300
BLWA 0810-1500/900
80MHz-1GHz
11500
15 HU, 800 mm
200
BLWA 0810-1500/1000D
80MHz-1GHz
11000
41 HU, 800 mm
400
BLWA 0810-1500/1200
80MHz-1GHz
17000
24 HU, 800 mm
315
BLWA 0810-1500D
80MHz-1GHz
11000
37 HU, 800 mm
450
BLWA 0810-1700/1350
80MHz-1GHz
20000
24 HU, 800 mm
300
BLWA 0810-2000/1000/700
80MHz-1GHz
15000
24 HU, 800 mm
300
BLWA 0810-2000/1000D
80MHz-1GHz
18000
2 ×32 HU, 800 mm
550
BLWA 0810-2000/1500D
80MHz-1GHz
18000
2 ×32 HU, 800 mm
600
BLWA 0810-2000/1500
80MHz-1GHz
17000
24 HU, 800 mm
310
BLWA 0810-2000
80MHz-1GHz
17000
32 HU, 800 mm
250
BLWA 0810-2500/1000
80MHz-1GHz
17000
24 HU, 800 mm
310
BLWA 0810-3000/2000D
80MHz-1GHz
25000
2 ×32 HU, 800 mm
700
BLWA 0810-5000/3000D
80MHz-1GHz
45000
3 ×37 HU, 800 mm
1200
-
main feature:
RF Power Amplifier BLWA 0810_80MHz-1GHz
-
Technical Parameters:
RF input interface :
N −f, standard on rear panel
RF output interface:
standard on the rear panel,
<1 kW ,Nf;
1 kW~2kW , 7-16-f;
>2 kW, 13-30-f or EIA 15/8
power input:
Cable power:
<1000 VA ,100 - 240 V AC ±10% / 47 - 63 Hz;
1000 - 3000 VA , 200-240 V AC ±10% / 47 -63 Hz;
>3000 VA , 3x 400 V AC ±10% / 47 - 63 Hz
Operating schedule:
Via status display
Ambient temperature:
0 ... +45 °C
storage temperature:
-20 ... +85 °C
Relative humidity:
up to 95% ( no condensation)
Operating Altitude:
Up to 2000 m
Vibration and Shock
MIL-STD-810 G
cool down:
Overall forced air cooling, air intake at the front and exhaust at the rear