EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
RTO2000 oscilloscope
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: RTO2000 oscilloscope
- Commodity ID: 1064835430282317824
- 品牌11: ROHDE&SCHWARZ
- 描述: RTO ® The 2000 series oscilloscopes are designed specifically to meet the challenges of multi domain measurement, with a bandwidth of 600 MHz to 6 GHz, leading the way in time and frequency domain testing.
- 品牌: ROHDE&SCHWARZ
Designed to meet multidomain measurement challenges, the RTO®2000 Series oscilloscopes lead the way in time and frequency domain testing with bandwidths from 600 MHz to 6 GHz. With superior signal fidelity, waveform capture rates of up to 1 million waveforms per second, and up to 16-bit vertical resolution, you can perform measurements quickly and accurately. The capacitive touchscreen is equipped with SmartGrid and is simple and intuitive to use.
-
Waveform capture rates up to 1 million waveforms per second for fast signal faults
2 Gsample storage depth for analysis of long sequences
Up to 16-bit vertical resolution
Multi-channel spectrum analysis
Bandwidth: 600 MHz to 6 GHz
Maximum sample rate: 20 Gsample/s
Maximum storage depth: 2 Gsample
Up to 16-bit vertical resolution
MSO: 16 selectable digital channels for upgrades
-
Vertical systems
Number of channels
R&S®RTO2002/R&S®RTO2012
R&S®RTO2022/R&S®RTO20322
R&S®RTO2004/R&S®RTO2014
R&S®RTO2024/R&S®RTO2034
R&S®RTO2044/R&S®RTO20644
Analog bandwidth (–3 dB) and rise time (50 Ω hours)
R&S®RTO2002 and R&S®RTO2004
600 MHz,583 ps
R&S®RTO2012 and R&S®RTO2014
1 GHz,350 ps
R&S®RTO2022 and R&S®RTO2024
2 GHz,175 ps
R&S®RTO2032 and R&S®RTO2034
3 GHz,116 ps
R&S®RTO2044
4 GHz,100 ps
R&S®RTO2064
Quad: 4 GHz, 100 ps
Dual channel: 6 GHz, 76 psAll models are scalable to bandwidths up to 6 GHz.
impedance
50 Ω ±1.5%
1 MΩ ±1% at 15 pF (measured value)Input sensitivity
Maximum bandwidth is supported in all ranges
50 Ω: 1 mV/div to 1 V/div,
500 μV to 1 V (optional);
1 MΩ: 1 mV/div to 10 V/div,
500 μV to 10 V (optional)ENOB for analog-to-digital converters
Full-scale sine wave with <–3 dB frequency bandwidth
> 7 Bits (measured value)
Acquisition system
Real-time sample rate
R&S®RTO200x/201x/202x/203x
Up to 10 G sample/s per channel
R&S®RTO2044/2064
Up to 10 G sample/s on quad channels
Up to 20 G sample/s at dual channelCapture storage
Standard, per-channel/single-channel activation
R&S®RTO2000: Dual-channel model: 50/100 M sample
R&S®RTO2000: Quad channel model: 50/200 M sampleMaximum upgrade (R&S®RTO-B110 option),
Per-channel/single-channel activationR&S®RTO2000: Dual-channel model: 1/2 G sample
R&S®RTO2000: Quad channel model: 1/2 G sampleMaximum waveform capture rate
continuous capture and display,
10 Gsample/s,1 ksample1 000 000 Waveforms/sec
Hyper-segmented storage mode
< 300 ns Dead zone time
Extraction mode
Any decimation mode and waveform algorithm combination, up to 3 waveform displays per channel
sampling, peak detection, high resolution,
root mean squareWaveform algorithm
Close, envelope, average
Interpolation mode
linear, sin(x)/x, sample and hold
Horizontal system
Time base range
25 ps/div to 10000 s/div
precision
After delivery/calibration
R&S®RTO-B4 option±5 ppm
±0.02 ppmTrigger the system
Trigger type
Edge, Glitch, Width, Trunt, Window, Timeout, Interval, Slope, Data2clock, Pattern, Status, Serial Pattern, TV/Video, Serial Bus Trigger (Option), Zone Trigger (Option)
Zone trigger (optional)
Logical combinations of up to 8 polygons intersecting or disjointing: measurement channels, spectra, mathematical operations
sensitivity
Trigger hysteresis definition
Can be adjusted automatically or manually
(0 div to 5 div)Common data
size
W x H x D
427 mm x 249 mm x 204 mm
(16.81 in x 9.8 in x 8.03 in)weight
9.6 kg (21.2 lbs)
screen
12.1" LC TFT capacitive color touch screen,
1280 pixels x 800 pixels (XGA)interface
1 Gbps LAN, Type A: 2 x USB 3.1, 2 x USB 2.0; Type B: 1 x USB 3.1, GPIB (option), DVI and Display Port (for external monitor), external trigger, trigger output