EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
SMA100B RF Signal Generator
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: SMA100B RF Signal Generator
- Commodity ID: 1064837023442554880
- 品牌11: ROHDE&SCHWARZ
- 描述: R&S ® The SMA100B RF and microwave signal generators provide top-notch performance.
- 品牌: ROHDE&SCHWARZ
The R&S® SMA100B RF and microwave signal generator offers top performance. It provides the purest output signal while maintaining the highest output power, far exceeding the competition. As the world's leading signal generator, it can complete the most demanding component, module and system test and measurement tasks in the fields of radio frequency semiconductor, wireless communication and aerospace and defense.
-
Frequency ranges from 8 kHz to 3 GHz, 6 GHz, 12.75 GHz, 20 GHz, 31.8 GHz, 40 GHz, 50 GHz, and 67 GHz (up to 72 GHz in overrange mode).
Best-in-class SSB phase noise: –152 dBc (typ) at 1 GHz and –132 dBc (typ) at 10 GHz at 10 kHz offset.
Virtually no broadband noise: –162 dBc (measured) at 10 GHz with 30 MHz offset.
The maximum output power exceeds 30 dBm in a wide frequency range.
Very low harmonics.
Advanced graphical user interface with touch display.
-
frequency
Frequency Range
R&S®SMAB-B103
8 kHz to 3 GHz
R&S®SMAB-B106
8 kHz to 6 GHz
R&S®SMAB-B112
8 kHz to 12.75 GHz
R&S®SMAB-B120
8 kHz to 20 GHz
R&S®SMAB-B131
8 kHz to 31.8 GHz
R&S®SMAB-B140/-B140N
8 kHz to 40 GHz
R&S®SMAB-B150/-B150N
8 kHz to 50 GHz
R&S®SMAB-B167/-B167N
8 kHz to 67 GHz (up to 72 GHz in overrange mode)
Level
Maximum Specified Output Power (PEP)
R&S®SMAB-B103/-B106
Standard
f = 3 GHz
+19 dBm
f = 6 GHz
+19 dBm
R&S®SMAB-K31
f = 3 GHz
+25 dBm
f = 6 GHz
+25 dBm
R&S®SMAB-K31和R&S®SMAB-B32
f = 3 GHz
+30 dBm
f = 6 GHz
+30 dBm
R&S®SMAB-B112/-B120
Standard
f = 12.75 GHz
+18 dBm
f = 20 GHz
+17 dBm
R&S®SMAB-K33
f = 12.75 GHz
+20 dBm
f = 20 GHz
+20 dBm
R&S®SMAB-K33 和 R&S®SMAB-B34
f = 12.75 GHz
+27 dBm
f = 20 GHz
+24 dBm
R&S®SMAB-B131/-B140/-B140N
Standard
f = 31.8 GHz
+13 dBm
f = 40 GHz
+13 dBm
R&S®SMAB-B35
f = 31.8 GHz
+17 dBm
f = 40 GHz
+16 dBm
R&S®SMAB-B35 和 R&S®SMAB-K36
f = 31.8 GHz
+22 dBm
f = 40 GHz
+19 dBm
R&S®SMAB-B150/-B150N/-B167/-B167N
Standard
f = 50 GHz
+5 dBm
f = 67 GHz
+5 dBm
R&S®SMAB-B37/-B39
f = 50 GHz
+11 dBm
f = 67 GHz
+9 dBm
R&S®SMAB-B37/-B39 和 R&S®SMAB-K38/-K40
f = 50 GHz
+18 dBm
f = 67 GHz
+10 dBm
Spectral purity
SSB Phase noise
f = 1 GHz, 1 Hz measurement bandwidth
Standard
Carrier offset = 20 kHz< –135 dBc,
–140 dBc(typical)
With R&S®SMAB-B709,
Carrier offset = 10 kHz< –140 dBc
With R&S®SMAB-B710(N),
Carrier offset = 10 kHz< –140 dBc,
–145 dBc(typical)
With R&S®SMAB-B711(N),
Carrier offset = 10 kHz< –147 dBc,
–152 dBc(typical)
SSB Phase noise (continued)
f = 10 GHz,
1 Hz measurement bandwidthStandard
Carrier offset = 20 kHz–115 dBc,
–120 dBc(typical)
With R&S®SMAB-B709,
Carrier offset = 10 kHz< –120 dBc
With R&S®SMAB-B710,
Carrier offset = 10 kHz–120 dBc,
–125 dBc(typical)
With R&S®SMAB-B711,
Carrier offset = 10 kHz–128 dBc,
–132 dBc(typical)
harmonic wave
The instrument is available with R&S SMAB-B103/-B106 and R&S®®SMAB-K31/-B32 options
10 MHz < f ≤ 6 GHz,P = 18 dBm
< –60 dBc
The instrument is available with R&S SMAB-B112/-B120 and R&S®®SMAB-K33/-B34 options
10 MHz < f ≤ 20 GHz,P = 16 dBm
< –55 dBc
The instrument is available with R&S SMAB-B131/-B140(N)/-B150(N)/-B167(N) and R&S®®SMAB-B35/-K36/-B37/-K38/-B39/-K40 options
10 MHz < f ≤ 31.8 GHz,P = 13 dBm
< –55 dBc
Non-harmonic
f = 1 GHz, carrier offset > 10 kHz, 10 dBm
< -92 dBc
f = 1 GHz, carrier offset > 10 kHz, 10 dBm,
带 R&S®SMAB-B711(N) 选件
< -100 dBc
Supported modulation modes
With R&S®SMAB-K720 option
Amplitude modulation, frequency modulation, phase modulation
Pulse modulation
With R&S®SMAB-K22 option
Rise/fall time
R&S®SMAB-K22,f > 700 MHz
<10 ns, 5 ns (typical)
On/off ratio
R&S®SMAB-K22
> 80 dB
Minimum pulse width
R&S®SMAB-K22
< 20 ns