EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Magnetic field testing system MTS-800 DC-250KHz
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Magnetic field testing system MTS-800 DC-250KHz
- Commodity ID: 1064838388009029632
- 描述: MTS800 is a compact testing system suitable for magnetic field testing and broadband generators. Its built-in components can automatically perform EMC testing, meeting various automotive electronic standards and generating high magnetic field strength req
- 品牌: FRANKONIA
The MTS800 is a compact test system for magnetic field testing and broadband generators. Its built-in components can automatically perform EMC tests, meet various automotive electronic standards, and generate high magnetic field strengths required by tests.
With the use of triaxial Helmholtz coils, the sensitivity test of magnetic fields up to 1000A/m can be automatically performed at DC-1kHz frequency. Low field strengths can be generated up to 250kHz. Use with triaxial coils improves the operability of the device, so there is no need to constantly invert the DUT during testing.
MTS800 meets the requirements of all relevant EMC and military standards. Test and measurement are program controlled and most test parameters are set automatically. As with any standard, the MTS800 software package contains test limits, but different values can also be defined by the user.
After testing, a test report will be automatically generated. Report layouts and formats are preset, and user-defined layouts are also available. An automatic calibration procedure guarantees efficient performance of the MTS800.
-
Frequency range for emission and susceptibility measurements: DC – 250 kHz
Integrated 800W precision power amplifier, signal source and low frequency receiver
All devices are available as standalone devices
Powerful and easy-to-use operating software, adapted to future standards
Standardized software, report generation, integration of external measuring devices for EUT monitoring
Allows connection of an external multimeter that controls the EUT
Fully automatic test using a three-axis Helmholtz coil, software control to generate magnetic fields in three directions of x/y/z, without rotating the EUT.
Wide range of test accessories available
-
Voltage input (receiver)
Frequency Range:
DC - 250 kHz
input resistance:
1MΩ / 50 Ω
Connector:
XLR, unbalanced
Maximum input voltage:
100V continuous, 10V (50 ohms)
Gain:
-20/0/20/40 dB preamplifier, 0/20/40 dB ADC amplifier
current input
Frequency Range:
DC - 250 kHz
Diversion:
10mΩ / 1Ω / 100Ω
Maximum input current:
20A continuous (overload protected), 1 ohm shunt, protected by an additional 1.5A fuse
Connector:
4mm safety jack
Measuring range:
20 A, 10 A, 1 A, 100 mA, 10 mA, 1mA with automatic bias and gain
AD converter
Resolution:
16Bit
Sampling Rate:
1.25MSPS
Aliasing filter
0.01dB Tschebyscheff filter, fg = 260 kHz, filter off
generator
Frequency Range:
DC - 250 kHz
Output Impedance:
50 Ω
Connector:
BNC, unbalanced
Signal:
Sine wave/square wave/triangular wave/DC
amplitude:
0 - 10V AC, - 10V - + 10V DC
resolution
12 Bit (2.5mV)
amplifier
Frequency Range:
DC - 1 MHz
Connector:
Input-BNC, Output-4mm safety jack
Current:
16Aeff
Voltage:
50Veff / 75 VDC
distortion
(DC-100kHz, load ≥4 ohms):
0.10%
general data
DUT control connector
9-pin Sub-D,RS232
connector to computer connection
USB
temperature range
0-40℃
Preheat time
15 minutes
Install
Rack 19 or desktop computer case
size
449×177×580mm
weight
About 40kg (gross weight 34kg)
gain
10+/-0.1%(+/-0.01%/℃)