EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
ACS 500N6 single-phase AC voltage source
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: ACS 500N6 single-phase AC voltage source
- Commodity ID: 1064815712234262528
- 描述: The ACS 500N6 is a single-phase AC power source designed for harmonic and flicker testing.
- 品牌: EM TEST
The ACS 500N6 is a single-phase AC power source designed for harmonic and flicker testing. It meets the requirements of EN/IEC 61000-3-2, EN/IEC 61000-3-3 and JIS C 61000-3-2 standards, and can provide perfect and stable sinusoidal voltage signals required by the standards for testing. Regardless of the power supply frequency of the power supply, or even if the voltage is unstable, it does not affect it to complete the fully compatible harmonic and flicker analysis.
-
main feature:
Frequency range 10 Hz - 80 Hz
Output power up to 6,000 VA
Output voltage up to 300 V
Can withstand large energy surge current
Remote control by DPA 500N Harmonic and Flicker Analyzer via RS 232 interface
Standards compliant:
EN 61000-3-2
EN 61000-3-3
IEC 61000-3-2
IEC 61000-3-3
HE C 61000-3-2
advantage:
Sinusoidal voltages for harmonic and flicker measurements
Harmonics and flicker testing requires a clean AC source as required by the standard. The ACS 500N6 guarantees an output sinusoidal voltage with a distortion rate of less than 0.1%, regardless of the load condition. Voltage regulation is maintained at 0.1% even with load changes.
Regardless of the power supply conditions, ACS 500N6 can provide pure and stable sinusoidal voltage signal and frequency according to the standard requirements. Its power can reach 6,000 VA, according to the test requirements of EN / IEC 61000-3-2, EN / IEC 61000-3-3 and JIS C 61000-3-2 standards, it can test the equipment under test not exceeding 16 A .
The ACS 500N6 AC voltage source has overheating, overcurrent, overvoltage and undervoltage protection functions.
EM TEST DPA 500N series harmonic and flicker analyzer can realize remote control to ACS 500N6 through the test software dpa.control via RS232 interface.
-
output
voltage range
0 V - 300 V AC
Voltage resolution
0.025 % (12 bit)
Output frequency
10 Hz - 80 Hz
106 kPa(060 mbar)
frequency resolution
0.02 Hz
Frequency Accuracy, Stability
100 ppm
Output Power
6,000 VA
output connector
banana plug
Output current, 50Hz
Continuous: up to 24 A
RMS value (up to 3 s): 47 A
Repetitive peak: 200 A
Output current, 60Hz
Continuous: 24.9 A max
RMS value (maximum 3 s): 47.9 A
Repetitive peak: 200 A
Adjustment
voltage monitoring
Internal or external, 4-wire
Total Harmonic Distortion
less than 0.1 %
Output Voltage Stability
Better than 0.1 %
Output Voltage Accuracy
Better than 0.5 %
Maximum Voltage Compensation
5% f.s.
Protect
overcurrent protection
Overheating protection
overvoltage protection
undervoltage protection
enter
supply voltage
3 × 400 V (3P,N,PE)
Input Current
32A (16A/27A , Neutral)
line frequency
45 Hz - 65 Hz
fuse
3 × 16 A (internal)
connector
Type CEE , 32 A
Environmental requirements
temperature
0°C - 35°C
Relative humidity
80 % without condensation
control
interface
RS 232 , 9-pin SubD
Exterior
size
19" / 6HU
weight
40 kg
volume
287 mm x 449 mm x 500 mm
option
DPA 500N
16 A Harmonic and Flicker Analyzer
MRAC 25
25 HU system cabinet with safety circuit
other models
ACS 500N3
3 kVA AC voltage source
Output Power
3,000 VA
Input voltage/current
230 V (L ,N,PE),16 A
Output current, 50Hz
Continuous: 12.1 A max
RMS value (maximum 3s): 21.8 A
Output current, 60Hz
Continuous: 12.5 A max
RMS value (maximum 3s): 22 A