Wisdom

Product


EMC Testing Solution Provider


ENV432 4-Wire V-Network (9k-30M)

Brand:

ROHDE&SCHWARZ

ENV432 4-Wire V-Network (9k-30M)
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: ENV432 4-Wire V-Network (9k-30M)
    • Commodity ID: 1064763895022505984
    • 品牌11: ROHDE&SCHWARZ
    • 描述: R&S®The ENV432 four-wire V-shaped network meets the requirements of CISPR 16-1-2, EN 55016-1-2 and ANSI C63.4 for V-shaped networks. It has an analog impedance of (50 μH 5Ω) | | 50Ω in the frequency range of 9 kHz to 30 MHz.
    • 品牌: ROHDE&SCHWARZ

            The R&S®ENV432 four-wire V-network meets the requirements of CISPR 16-1-2, EN 55016-1-2 and ANSI C63.4 for V-networks and simulates impedance in the frequency range from 9 kHz to 30 MHz is (50 μH + 5 Ω) || 50 Ω. The R&S®ENV432 has a Schuko socket (EUT 1) and a CEE 32 A socket (EUT 2) for connection to the equipment under test (EUT).

  • main feature:

    • Frequency range from 9 kHz to 30 MHz .
    • Power handling capacity (up to 32 A), constant current .
    • Analog impedance (50 μH + 5 Ω) || 50 Ω according to CISPR 16-1-2 .
    • V-shaped network according to CISPR, EN, VDE, ANSI, FCC Part 15 and MIL - STD-461D, E and F.
    • Calibrated to CISPR 16-1-2 and ANSI C63.4 .

    Features and Benefits:

    • Hollow core design and simulated hands

    The R&S®ENV432 four-wire V-network is based on air-core inductors and includes a simulated hand.

    • Built-in 10 dB attenuator

    To ensure standard impedance (regardless of input attenuation of the measuring receiver), the R&S®ENV432 is equipped with a 10 dB attenuator.

    • Built-in pulse limiter (can be turned off)

    A built-in pulse limiter (can be switched off) protects the measurement receiver input.

    • automatic temperature monitoring

    The fan of the R&S®ENV432 switches on automatically when the internal temperature of the enclosure reaches approximately +50 °C. This protects the V-network under high constant current loads.

    • Remote control of TTL levels (compatible with Rohde & Schwarz measuring receivers)

    The TTL control input can be driven by a controller or a Rohde & Schwarz measurement receiver for remote control of phase selection in automated test systems.

  • Frequency Range

     

    9 kHz to 30 MHz

    Analog Impedance

     

    50 μH + 5 Ω) || 50 Ω

    Error limits according to CISPR 16-1-2

    amplitude and phase

    ±20% and ±11.5°

    Decoupling fading between power supply and measuring receiver port according to CISPR 16 1 2

    9 kHz to 50 kHz

    >0 dB to >40 dB (increases linearly through the logarithm of frequency)

     

    50 kHz to 30 MHz

    > 40 dB

    Test path to EUT

    Maximum allowable constant current

    EUT 1

    16 A

    voltage

    EUT 1

    0 V to 240 V AC + 10%

    DC voltage

    EUT 1

    0 V to 350 V DC + 10%

    Maximum allowable constant current

    EUT 2

    32 A

    Peak current (temporary)

    EUT 2

    50 A (2 minutes)

    voltage

    EUT 2

    0 V to 240/415 V AC + 10%

    DC voltage

    EUT 2

    0 V to 350 V DC + 10%

    power frequency

     

    0 Hz to 60 Hz + 5%

    Test path to measurement receiver

    Maximum permissible EUT radio frequency disturbance power

     

    5W

    Voltage division coefficient between EUT and measuring receiver port

    Built-in attenuator, calibration data provided (using V-network)

    10 dB – 0.5 dB/+ 2.0 dB

    Response threshold of built-in pulse limiter

    can be closed

    140 dB (μV) (nominal)

    Fan power supply and control logic

    voltage

    115V setting

    100 V to 120 V AC ± 10%

     

    230V setting

    220 V to 240 V AC ± 10%

    power frequency

     

    50 Hz to 60 Hz ± 5%

    power consumption

     

    100 VA (nominal)

    Connector

    Power supply and DC voltage output

    Front panel, EUT 1

    Schuko socket

    Power supply and DC voltage output

    Front panel, EUT 2

    CEE socket (6h)

    RF output

    Front panel, to test receiver

    N-type negative, 50 Ω

    simulated hand

    front panel

    4 mm fitting, female, clamp with knurled edge

    Power supply and DC voltage input

    rear panel, power supply

    CEE built-in connector (6h)

    Supply voltage input (auxiliary voltage)

    Rear panel, power supply for fans and remote control

    Cryogenic Connectors with Mains Filters

    remote control input

    rear panel, remote control

    25 contacts, D-Sub, female

    safety ground wire

    Front and rear panels

    M8 threaded bolt

    RF Reference Ground

    both sides

    Ground rod with seven M6 threads

    general data

    Operating temperature range

     

    +5°C to +45°C

    storage temperature range

     

    –40°C to +70°C

    total measurement

    W × H × D

    446 mm × 289 mm × 500 mm

    weight

     

    24 kg

    Electrical Safety

    Carefully follow the instructions in the manual

    According to EN 61010-1

    EMC

     

    According to IEC/EN 61326-1

    emission

     

    Class B, meeting the living environment requirements

    Anti-jamming

     

    Comply with industrial environment requirements

全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ