EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
ENV4200 4-wire V-network (150k-30M)
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: ENV4200 4-wire V-network (150k-30M)
- Commodity ID: 1064764054020182016
- 品牌11: ROHDE&SCHWARZ
- 描述: R&S®The ENV4 200 200 A four-wire V-type network meets the requirements of CISPR 16-1-2, EN 55016-1-2, ANSI C63.4 and FCC Part 15 for V-type networks with impedance of 50 μH | 50 Ω in the frequency range of 150 kHz to 30 MHz.
- 品牌: ROHDE&SCHWARZ
The R&S®ENV4200 200 A four-wire V-network complies with CISPR 16-1-2, EN 55016-1-2, ANSI C63.4 and FCC Part 15 for impedances of 50 μH | 50 Ω in the frequency range 150 kHz to 30 MHz V-network requirements. It is used to measure the RFI voltage on AC and DC mains connections of equipment under test carrying very high currents. It is based on an air core inductor and contains an artificial hand and a pulse limiter.
-
main feature:
- The R&S®ENV4200 V-type network complies with CISPR 16-1-2, EN55016-1-2, FCC Part 15 and ANSI C63.4 impedance requirements for V-type networks in the frequency range of 150kHz-30MHz. It is used to measure the RF disturbance voltage on AC and DC power supplies under EUT high current conditions. It uses an air core inductor and includes a simulated hand.
- The R&S®ENV4200 comes with a calibration report for the voltage division factor, and the calibration refers to CISPR16-1-2 and ANSIC63.4.
Features and advantages:
- Hollow core design and artificial hand
- The R&S®ENV4200 200 four-wire V-network is based on an air-core inductor and includes an artificial hand in order to simulate the effect of the user's hand when measuring disturbance voltages.
- Built-in 10dB attenuator pad
- To ensure that the standard impedance is independent of the input attenuation of the measuring receiver, the R&s®ENV-4200 is equipped with a 10 dB attenuator pad.
- Built-in pulse limiter (can be turned off)
- A built-in pulse limiter can be switched off to protect the input of the measurement receiver.
- automatic temperature monitoring
- The fan of the R&S®ENV4200 switches on automatically when the internal temperature of the housing reaches approximately +50°C. This protects the V network in case of high constant current loads.
- Remote control with TTL level (compatible with Rohde & Schwarz measuring receivers)
- In automated test systems, the TTL control input can be driven by a controller or a Rohde & Schwarz measurement receiver for remote control of phase selection.
-
Frequency Range
0.15 MHz to 30 MHz
Impedance (magnitude and phase)
5μH//50Ω
Error limit ( according to CISPR16-1-2)
±20% amplitude
Decoupling factor between power supply and receiver
> 40dB
Maximum allowable continuous current
N, L1, L2, L3
200A
Maximum allowable AC voltage
N, L1, L2, L3
0 V to 400 V/690 V AC + 10%
Maximum allowable DC voltage
N, L1, L2, L3
0 V to 690 V DC + 10%
peak current
N, L1, L2, L3
250 A (2 minutes)
AC frequency
0 Hz to 60 Hz + 5%
Pulse limiter
1 4 0dBuV (can be shut down)
Voltage division factor between EUT and test receiver
10– 0.5 dB/+ 2.5 dB (with calibration data)
Maximum allowable EUT RF power
5 watts
AC power
115V 100 V to 120 V AC ± 10%
230V 220 V to 240 V AC ± 10%
AC power frequency
50 Hz to 60 Hz ± 5%
Power consumption
100 VA
AC and DC voltage output connectors
multi-point contact connector
AC and DC voltage input connectors
multi-point contact connector
Analog Hand Connector
4 mm, female
protective earth connector
M10 bolt
RF output connector
50 Ω
remote control input connector
25-pin D-Sub, female
RF reference ground connector
Earth rod with 11 M6 threads
Operating temperature
+5°C to +40°C
storage temperature
-40°C to +70°C
Dimensions (WxHxD)
446mm x 325mm x 595mm
weight