EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
ESW EMI Measurement Receiver (1Hz-44G)
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: ESW EMI Measurement Receiver (1Hz-44G)
- Commodity ID: 1064764568107634688
- 品牌11: ROHDE&SCHWARZ
- 描述: R&S®The ESW is the 1 EMI test receiver with excellent RF characteristics, high dynamic range and measurement accuracy.
- 品牌: ROHDE&SCHWARZ
The R&S®ESW is an EMI test receiver with excellent RF characteristics, high dynamic range and measurement accuracy. Compliant with CISPR, EN, MIL-STD-461, DO-160 and FCC standards, this test receiver meets the most stringent certification measurement requirements. With FFT-based time-domain scanning, the R&S®ESW is able to capture and measure interference spectra in almost real-time. With the instrument's real-time spectrum analysis and spectrogram capabilities, users can analyze interfering signals and their history in detail. The multi-view mode facilitates visual display of results, even showing multiple modes of operation.
-
main feature:
- Frequency ranges are 1 Hz to 8 GHz, 1 Hz to 26.5 GHz, and 1 Hz to 44 GHz .
- Comply with CISPR16-1-1, ANSIC63.2, MIL-STD-461 and FCC standards .
- Unparalleled dynamic range and accuracy for demanding certification measurements.
- Ultra-fast measurements with FFT-based time-domain scanning .
- Use optional high-pass filter for ISM bands and notch filter preselection .
- EMI test receiver and signal and spectrum analyzer all in one .
- Real-time spectrum analysis with 80 MHz bandwidth and spectrogram function (R&S®ESW-K55 option) .
- The multi-view feature enables the visualization of multiple operating modes on a single screen.
Features and Benefits:
- Hollow core design and simulated hands
The R&S®ENV432 four-wire V-network is based on air-core inductors and includes a simulated hand.
- Standards Compliant EMI Measurements
Certified measurements.
Perform standards-compliant EMI measurements in spectrum analyzer mode .
- RF performance to meet stringent requirements
Extremely wide dynamic range.
Low DANL (–168 dBm typical for f ≤ 1 GHz) .
1 dB higher compression point (+15 dBm) for RF front end .
High third-order intercept (TOI) (+25 dBm typical) .
Excellent measurement accuracy ( ±0.37 dB for f ≤ 8 GHz) .
- Integrated preselection filter and preamplifier
Integrated preselection filters ( 21 filters) are standard .
Additional high-pass filter (2 MHz) for suppressing data carriers and interfering signals on the AC power line .
Notch filters for suppressing strong carrier signals in the license-exempt 2.4 GHz and 5.8 GHz ISM bands .
- Ultra-fast measurements with FFT-based time-domain sweeps
Conducted disturbance levels are measured in real time with quasi-peak and CISPR average weighting .
- Real-time spectrum analysis for detailed investigation of interference (with option)
Take real-time measurements with bandwidths up to 80 MHz .
Seamlessly display frequency spectra with waterfall plots.
Use the persistence mode (spectral histogram) to clearly distinguish between pulsed and continuous interference.
Frequency mask triggering for accurate and reliable detection of infrequent spectral events.
- Easy to operate, intuitive display of results
Scan tables visually.
Multiple Views: Visualize multiple results.
Optimized, touchscreen-based user interface for quick access to all functions.
Integrated online help.
Save the results and instrument settings.
- automated test
Preview measurement - data reduction - final measurement .
R&S®EMC32 EMC measurement software for remote control of measurements and automation of EMI test procedures .
Report generator for documenting measurement results.
- Four-channel click rate measurement
Click rate analysis according to CISPR14-1 standard .
The results are recorded.
- Data Protection and Remote Control
Removable Hard Disk Drive (HDD) for confidentiality and security of test data .
Remote control via GPIB or LAN .
Drivers for LabView, LabWindows/CVI, VXI Plug & Play .
Free firmware updates to keep up with new developments.
-
frequency
Frequency Range
R&S®ESW8
1 Hz to 8 GHz
R&S®ESW26
1 Hz to 26.5 GHz
R&S®ESW44
1 Hz to 44 GHz
Aging rate
R&S®ESW-B4 OCXO precision frequency reference
±3×10 -8
±1×10 -7
bandwidth
resolution bandwidth
Standard filter (–3 dB)
1 Hz to 10 MHz
EMI filter (–6dB)
1 Hz、100 Hz、200 Hz、1 kHz、9 kHz、10 kHz、100 kHz、120 kHz、10 MHz
Geophone
receiver mode
Maximum peak value, minimum peak value, quasi-peak value, RMS value, average value, average value with metering time constant (CISPR average value), RMS average value (CISPR RMS)
APD measurement function
lowest magnitude probability
10 -7
maximum capture time
120 s
Capture Bandwidth (–6 dB)
200 Hz、9 kHz、120 kHz、1 MHz
Third order cut-off point (TOI)
R&S®ESW8, R&S®ESW26, R&S®ESW44, RF attenuation = 0 dB, level 2 × –15 dBm, ∆f > 5 × RBW, preselection off, preamplifier off
10 MHz ≤ fin < 1 GHz, > +20 dBm, 25 dBm (typical)
1dB compression
RF attenuation = 0 dB, preselect off, preamp off
fin ≤ 3 GHz, +15 dBm (nominal)
preselection filter
state
receiver mode
always on
analyzer mode
On/Off (optional)
Number of preselection filters
twenty one
Preamplifier (switchable)
1 kHz to 8 GHz
20dB (nominal)
Displayed Average Noise Level (DANL)
R&S®ESW8 (receiver mode, RF attenuation = 0 dB, termination = 50 Ω, logarithmic scale normalized to 1 Hz RBW, RBW = 1 kHz, VBW = 1 Hz, +5°C to +40°C, preselection on, preamplifier on)
1 MHz ≤ f < 1 GHz
<–165 dBm, typical –168 dBm
receiver mode
time domain scan
CISPR Band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 100 ms, peak detector
110 ms (total measurement time)
CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 1 s, quasi-peak detector and CISPR average detector
2 s (total measurement time)
CISPR Band C/D, 30 MHz to 1000 MHz, RBW = 120 kHz, measurement time = 10 ms, peak detector
620 ms (total measurement time)
CISPR band C/D, 30 MHz to 1000 MHz, RBW = 9 kHz, measurement time = 10 ms, peak detector
840 ms (total measurement time)
CISPR band C/D, 30 MHz to 1000 MHz, RBW = 120 kHz, measurement time = 1 s, quasi-peak detector
80 s (total measurement time)
CISPR band C/D, 30 MHz to 1000 MHz, RBW = 9 kHz, measurement time = 1 s, quasi-peak detector and CISPR average detector
67 s (total measurement time)
Overall measurement uncertainty
preselection off
10 MHz < f ≤ 3.6 GHz
±0.27 dB
Dimensions (nominal)
Width x Height x Depth, including front handle and rear feet
462 mm × 240 mm × 504 mm (18.15 in × 9.44 in × 19.81 in)
Net weight without options (nominal)
R&S®ESW8
20.6 kg (45.42 lb)
R&S®ESW26
22.1 kg (48.72 lb)
R&S®ESW44
25.2 kg (55.56 lb)