EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
FSV Signal and Spectrum Analyzer (10Hz-40G)
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: FSV Signal and Spectrum Analyzer (10Hz-40G)
- Commodity ID: 1064765155486355456
- 品牌11: ROHDE&SCHWARZ
- 描述: R&S®The FSV is the ideal instrument for all general-purpose measurement tasks (test bench, production and field applications).
- 品牌: ROHDE&SCHWARZ
The R&S®FSV and R&S®FSVA belong to the family of multifunctional signal and spectrum analyzers for users involved in the development, production, installation and maintenance of RF systems.
The R&S®FSV is the ideal instrument for all universal measurement tasks (test bench, production and field applications). The instrument provides digital modulation analysis for the latest cellular and wireless standards, measuring components, chipsets and base stations at an analysis bandwidth of up to 160 MHz.
Typical measurement tasks include standards-compliant spectral emission mask measurements as well as spurious and adjacent channel leakage ratio (ACLR) measurements.
Measurement applications covering EMI diagnostics, phase noise, noise figure, analog demodulation, and vector signal analysis complete the range of functions offered by the universal R&S®FSV.
-
main feature:
- The frequency range is up to 4/7/13.6/30/40 GHz .
- Up to 160 MHz signal analysis bandwidth .
- Touch screen based user interface for easy and intuitive operation (5 GHz) .
- 0.4 dB level measurement uncertainty (up to 7 GHz) .
- Phase noise is –110 dBc (1 Hz) at 10 kHz frequency offset .
- +15 dBm Third Order Intercept (TOI) .
- Displayed average noise level (DANL) in 1 Hz bandwidth: –155 dBm at 1 GHz carrier frequency, –147 dBm at 30 GHz carrier frequency; with R&S®FSV-B24 preamplifier: –162 dBm at 30 GHz carrier frequency .
- General measurement applications covering phase noise, noise figure, vector signal analysis, analog demodulation, EMI diagnostics .
- Wireless measurement applications supporting LTE (including LTE-Advanced), WLAN (including IEEE 802.11ac), WCDMA/HSPA+, TD-SCDMA, GSM/EDGE, CDMA2000®/1xEV-DO, Bluetooth® .
- In the case of harmonic mixers, frequencies up to 500 GHz are possible .
- Use a removable solid-state drive or hard drive to ensure the confidentiality of test data.
-
frequency
Frequency Range
R&S®FSV4
10 Hz to 4 GHz
R&S®FSV7
10 Hz to 7 GHz
R&S®FSV13
10 Hz to 13.6 GHz
R&S®FSV30
10 Hz to 30 GHz
R&S®FSV40
10 Hz to 40 GHz
Frequency Reference Aging
1×10 -6
with R&S®FSV-B4 option
1×10 -7
With R&S®FSV-B14 ultra-high precision reference frequency option
4× 10-9
Resolution/Bandwidth
resolution bandwidth
standard scan
1 Hz to 10 MHz
Standard scan, zero span
Selectable 1 Hz to 10 MHz, 20 MHz, 28 MHz 1) , 40 MHz
FFT scan
1 Hz to 300 kHz
channel filter
100Hz to 5MHz
EMI filter
200 Hz、9 kHz、120 kHz、1 MHz
video filter
1 Hz 至 10 MHz、20 MHz、28 MHz、40 MHz1)
Signal Analysis Bandwidth
28 MHz 1)
with R&S®FSV-B70 option
40MHz 2)
with R&S®FSV-B160 option
160MHz 3)
Displayed Average Noise Level (DANL)
DANL (1 Hz bandwidth)
1 GHz
–152 dBm, –155 dBm typical
3 GHz
–150 dBm, –153 dBm typical
7 GHz
–146 dBm, –149 dBm typical
13 GHz
–148 dBm, –151 dBm typical
30 GHz
–144 dBm, –147 dBm typical
40 GHz
–136 dBm, –139 dBm typical
with preamplifier,
R&S®FSV-B22 option1 GHz
–162 dBm, –165 dBm typical
3 GHz
–160 dBm, –163 dBm typical
7 GHz
–156 dBm, –159 dBm typical
with preamplifier,
R&S®FSV-B24 option10 GHz
–164 dBm, –167 dBm typical
30 GHz
–159 dBm, –162 dBm typical
40 GHz
–154 dBm, –156 dBm typical
Intermodulation
Third order cut-off point (TOI)
f < 3.6 GHz
+13 dBm, +16 dBm typical
3.6GHz to 30GHz
+15 dBm, +18 dBm typical
WCDMA ACLR Dynamic Range
No noise compensation
70 dB
With noise compensation
73 dB
phase noise
1 GHz carrier frequency
10 kHz carrier offset
–106 dBc (1 Hz), –110 dBc (1 Hz) typical
100 kHz carrier offset
–115 dBc (1 Hz)
1 MHz carrier offset
–134 dBc (1 Hz)
Overall measurement uncertainty
3.6 GHz
0.29 dB
7 GHz
0.39 dB
R&S®FSV-B9 trace generator
Frequency Range
R&S®FSV4
100 kHz to 4 GHz
R&S®FSV7/13/30/40
100 kHz to 7 GHz
frequency offset
up to 1 GHz
Level range
–60 dBm to 0 dBm