EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
SMB100A RF Signal Generator (9k-6G or 100k-40G)
Brand:
ROHDE&SCHWARZ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: SMB100A RF Signal Generator (9k-6G or 100k-40G)
- Commodity ID: 1064765547284680704
- 品牌11: ROHDE&SCHWARZ
- 描述: Compact Versatile R & S®SMB100A microwave signal generator frequency up to 40 GHz
- 品牌: ROHDE&SCHWARZ
The compact and versatile R&S®SMB100A microwave signal generator operates up to 40 GHz and offers excellent spectral purity combined with high output power. In addition, the generator is easy to operate, full-featured and low cost of ownership.
For higher frequencies, the frequency range of the R&S®SMB100A can be easily extended with the R&S®SMZ frequency multiplier. In the frequency range from 50 GHz to 110 GHz, the R&S®SMB100A as well as the R&S®SMZ solution combine easy operability with an accurate and adjustable output level (in the case of the R&S®SMZ170, the output level is not adjustable).
-
main feature:
- Wide frequency range from 100 kHz to 40 GHz .
- Offers excellent signal characteristics, very low SSB phase noise, typically –128 dBc at 1 GHz, 20 kHz offset .
- Output power up to +27 dBm (measured) .
- All important analog modulations as well as AM, FM, Phase and Pulse modulation are supported.
- Compact size (only 2 HU) and light weight .
-
Frequency Range
R&S®SMB-B101
9 kHz to 1.1 GHz
R&S®SMB-B102
9 kHz to 2.2 GHz
R&S®SMB-B103
9 kHz to 3.2 GHz
R&S®SMB-B106
9 kHz to 6 GHz
R&S®SMB-B112/-B1
9 kHz to 6 GHz
R&S®SMB-B112/R&S®SMB-B112L
100 kHz to 12.75 GHz
R&S®SMB-B120/R&S®SMB-B120L
100 kHz to 20 GHz
R&S®SMB-B131
100 kHz to 31.8 GHz
R&S®SMB-B140/R&S®SMB-B140L/R&S®SMB-B140N
100 kHz to 40 GHz
set time
SCPI mode
< 3 ms
list mode
< 1 ms
level
Maximum output power
R&S®SMB-B112/-B112L,
1 MHz < f ≤ 12.75 GHz+18 dBm
R&S®SMB-B120 and R&S®SMB-B31,
50 MHz < f ≤ 20 GHz+16 dBm
R&S®SMB-B120L and R&S®SMB-B31,
100 MHz < f ≤ 20 GHz+19 dBm
R&S®SMB-B131/-B140/-B140N
and R&S®SMB-B32,
50 MHz < f ≤ 40 GHz+19 dBm
R&S®SMB-B140L and R&S®SMB-B32,
50 MHz < f ≤ 40 GHz+16 dBm
Minimum specified output power
R&S®SMB-B112/-B131/-B140/-B140N
-120 dBm
R&S®SMB-B112L
-5 dBm
R&S®SMB-B120L/-B140L
0 dBm
Settling time
(no need to switch mechanical attenuators)SCPI mode
< 2.5 ms
list mode
< 1 ms
spectral purity
SSB phase noise
f = 1 GHz, carrier offset = 20 kHz, 1 Hz measurement bandwidth
< –122 dBc,
typical –128 dBcf = 10 GHz, carrier offset = 20 kHz, 1 Hz measurement bandwidth
< –102 dBc,
typical –108 dBcharmonic
R&S®SMB-B112/-B112L
1 MHz < f ≤ 6 GHz; level ≤13 dBm 1)
f > 6 GHz; level ≤10 dBm 1)< –30 dBc
R&S®SMB-B120/-B120L/-B131/-B140/ -B140N/-B140L
Standard; level ≤ 8 dBm 1)
f > 1 MHz
< –30 dBc
With R&S®SMB-B25/-B26 low harmonic option, low harmonic filter switched on, level ≤ 10 dBm 1)
1 MHz < f ≤ 150 MHz
< –30 dBc
150 MHz < f ≤ 3 GHz
< –58 dBc
3 GHz < f ≤ 20 GHz
< –50 dBc
f > 20 GHz
< –60 dBc (measured)
Supported Modulation Modes
AM
Standard
AM Depth
0% to 100%
FM/PM
Standard
Maximum FM Deviation
f = 10 GHz
32 MHz
Maximum phase modulation deviation
f = 10 GHz
320 rad
pulse modulation
R&S®SMB-K21/-K22 pulse modulator
rise/fall time
< 20 ns, typically < 5 ns
Switch ratio
> 80 dB
The minimum pulse width of the pulse generator output
10 ns
connectivity
remote control
GPIB IEEE-488.2
Ethernet (TCP/IP),
USBperipheral equipment
USB