EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
COUPLING NX5 Group Pulse&Surge Combined 3-phase Coupling/Decoupling Network
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: COUPLING NX5 Group Pulse&Surge Combined 3-phase Coupling/Decoupling Network
- Commodity ID: 1064841301632634880
- 描述: The NX series three-phase coupling/decoupling network is used to couple EFT/Burst pulses and surge pulses on DC lines or three-phase (4-wire or 5-wire) power systems, with EUT voltages up to 1000 VDC/3 x 690 VAC.
- 品牌: EM TEST
The NX series of three-phase coupling/decoupling networks are used to couple EFT/Burst pulses and surge pulses on DC line or three-phase (4-wire or 5-wire) power systems with EUT voltages up to 1000 VDC / 3 x 690 VAC. This includes the increasingly common testing of inverters used in the renewable energy sector (e.g. photovoltaic systems, wind power stations, electric vehicles). Fully meet EUTs with wide current ranges of 16A, 32A, 63A, 125A and 200A.
-
Automatic coupling of burst and surge waveforms
Various models with current 32A, 63A, 125A and 200A are available
Voltage can meet 3 x 690 VAC /1000 VDC
With coupling mode LED display function
With automatic selection of surge impedance function
Realize EM TEST compact NX automatic control
With railway standard EN 50121 option
-
CDN overview
Burst
EN/IEC 61000-4-4, the maximum voltage can reach 5.5kV
Surge
EN/IEC 61000-4-5, the maximum voltage can reach 5kV
current range
<32A:0A-32A
63A: >32A-63A
125A:>63A-125A
200A:>125A-200A
CDN 3X480VAC(PP) model
current range
model
16A
NX5 bs-3-480-16
32A
NX5 bs-3-480-32
63A
NX5 bs-3-480-63
125A
NX5 bs-3-480-125
With additional current ranges*
<32,63A
NX5 bs-3-480-63.1
<32,63,125A
NX5 bs-3-480-125.1
<32,63,125,200A
NX5 bs-3-480-200.1
CDN 3X690VAC(P-P)Model
current range
model
16A
NX5 bs-3-690-16
32A
NX5 bs-3-690-32
With additional current ranges*
<32,63A
NX5 bs-3-690-63.1
<32,63,125A
NX5 bs-3-690-125.1
<32,63,125,200A
NX5 bs-3-690-200.1
Railway industry CDN
Overview of CDN for the railway industry
coupling
Meets standard EN 50121 built-in 0.5 μF / 40Ω module
Group Pulse Burst
Meets the standard EN/IEC 61000-4-4 and has a pulse voltage of up to 5.5.kV
Surge Surge
Meets the standard EN/IEC 61000-4-5 and has a pulse voltage of up to 5kV
current range
<32A:0A-32A
63A: >32A-63A
125A:>63A-125A
200A:>125A-200A
CDN 3X480VAC(PP) model
current range
model
16A
NX5-R bs-3-480-16
32A
NX5-R bs-3-480-32
With additional current ranges*
<32,63A
NX5-R bs-3-480-63.1
<32,63,125A
NX5-R bs-3-480-125.1
<32,63,125,200A
NX5-R bs-3-480-200.1
CDN 3X690VAC(P-P)Model
current range
Models with additional current ranges*
<32,63A
NX5-R bs-3-690-63.1
<32,63,125A
NX5-R bs-3-690-125.1
<32,63,125,200A
NX5-R bs-3-690-200.1
CDN 3X690 VAC(P-P);1000VDC
current range
Models with additional current ranges*
<32,63A
NX5-R bs-3-690-63.3
<32,63,125A
NX5-R bs-3-690-125.3
<32,63,125,200A
NX5-R bs-3-690-200.3
Manual CDN for the railway industry
PCN 7-R s-1
manually coupled network,
7kVSurge pulses
EUT Maximum voltage 690VAC
Coupling: 0.5 uF / 40 Ω
Decoupling: Generator built-in
NX5 BS-3-480-16
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 16 A, 50/60 Hz
Connector
Input: MC 4mm safety terminal
Output: MC 4mm safety terminal
Size specifications
Size: 19 inches / 6HU, 448x286x500mm
Weight: Approx. 30kg
NX5 BS-3-480-32
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 32 A, 50/60 Hz
Connector
Input: MC 4mm safety terminal
Output: MC 4mm safety terminal
Size specifications
Size: 19 inches / 6HU, 448x286x500mm
Weight: Approx. 45kg
NX5 BS-3-480-63
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 63 A, 50/60 Hz
Connector
Input: CEE 480/63
Output: MC 6mm safety terminal
Size specifications
Size: RAC 25 IEC
Weight: Approx. 100kg
NX5 BS-3-480-125
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 125A, 50/60 Hz
Connector
Input: CEE 480/125
Output: MC 6mm safety terminal
Size specifications
Size: RAC 25 IEC
Weight: Approx. 200kg
NX5 BS-3-480-63.1
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 63A, 50/60 Hz
current range
<32 A, 63 A
Connector
Input: CEE 480/63
Output: MC 6mm safety terminal
Size specifications
Size: RAC 34 IEC
Weight: Approx. 100kg
NX5 BS-3-480-125.1
3Phase CDN
Meets EN/IEC 61000-4-4 and EN/IEC 61000-4-5
The group pulse reaches 5.5kV
The surge reaches 5kV
EUT Power supply
3 x 480 V, 125A, 50/60 Hz
current range
<32 A, 63 A,125A
Connector
Input: CEE 480/125
Output: MC 6mm safety terminal
Size specifications
Size: RAC 34 IEC
Weight: Approx. 180kg