EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CNV 504N/508N signal/data line coupling/decoupling network
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CNV 504N/508N signal/data line coupling/decoupling network
- Commodity ID: 1064844479149264896
- 品牌11: EMTEST
- 描述: Applying surge pulses and ringing wave pulses to unshielded asymmetric interconnected lines (signal/data lines) requires an independent coupling/decoupling network. EM TEST's CNV series 4-wire or 8-wire signal/data line coupling network is designed specif
- 品牌: EM TEST
The application of surge pulses and ringing wave pulses to unshielded asymmetric interconnects (signal lines/data lines) requires independent coupling/decoupling networks. EM TEST's CNV series 4- or 8-wire signal/data line coupling networks are designed for this application. According to EN/IEC 61000-4-5 and EN/IEC 61000-4-12, pulses can be coupled by capacitors, air discharge tubes or diodes depending on the characteristics of the in-line signal.
-
Coupling/decoupling networks according to EN/IEC 61000-4-5 and EN/IEC 61000-4-12
Surge test coupling with gas discharge tube and 0.5uF capacitive coupling (3.3uF capacitive coupling for ringwave test mode)
The decoupling inductance per wire is 20mH
Differential-mode or common-mode coupling modes are selectable
Test voltages up to 4kV, 7kV and 10kV respectively
Line voltage 50V (higher voltage network can be customized)
Line current 1A (can be customized for larger current networks)
-
504N line voltage 50V series
4KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 504N1
4kVCoupling voltage, line current 1A
CNV 504N1.1
4kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
7KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 504N2
7kVCoupling voltage, line current 1A
CNV 504N2.1
7kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
10KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 504N3
10kVCoupling voltage, line current 1A
CNV 504N3.1
10kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
504N line voltage 300V series
4KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 504N1.2
4kVCoupling voltage, line current 1A
CNV 504N1.3
4kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
7KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 504N2.2
7kVCoupling voltage, line current 1A
CNV 504N2.3
7kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
10KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 504N3.2
10kVCoupling voltage, line current 1A
CNV 504N3.3
10kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
508N line voltage 50V series
4KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 508N1
4kVCoupling voltage, line current 1A
CNV 508N1.1
4kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
7KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 508N2
7kVCoupling voltage, line current 1A
CNV 508N2.1
7kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
10KVModule, maximum line voltage, 35 VAC, 50 VDC
CNV 508N3
10kVCoupling voltage, line current 1A
CNV 508N3.1
10kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
- GDT Gas discharge 40 ohm
508N line voltage 300V series
4KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 508N1.2
4kVCoupling voltage, line current 1A
CNV 508N1.3
4kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
7KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 508N2.2
7kVCoupling voltage, line current 1A
CNV 508N2.3
7kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,
Ringing wave coupling
Fig. 9 IEC 61000-4-12 Ed.2,
- 3.3 μF capacitor
10KVModule, maximum line voltage, 250 VAC, 300 VDC
CNV 508N3.2
10kVCoupling voltage, line current 1A
CNV 508N3.3
10kVCoupling voltage, line current 4A, instantaneous 5A
Common data
Surge coupling
Meet the Fig. 9 IEC 61000-4-5 Ed.3,
- 0.5 μF/capacitor 40 ohm,