    • Commodity name: Compact NX5 Ultra-small anti-jamming signal simulator
    • Commodity ID: 1064482170488901632
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: Compact NX5 ultra-small electrical fast transient/burst, surge and voltage sag test equipment.
    • 品牌: EM TEST

      Compact NX5 Ultra-compact EFT/Burst, Surge and Dip test equipment.

      Compact NX5 ultra-small simulator is a multi-functional test equipment that can meet various requirements of international standards (basic standards and general standards) and product series standards for transient, pulse, surge and voltage drop tests. The Compact NX5 is equipped with an easy-to-use color touch screen, built-in single-phase coupling/decoupling network, and can perform three-phase EUT testing with an automatically controlled external coupling network (up to 200 A per phase), making it a The most economical solution for product development testing and fully compliant immunity testing for EU CE certification.

    maximum

  •   main feature:

      ● The lightest combined simulator with a 7” touch screen

      ● Built-in burst test module (5.5 kV), surge test module (5.0 kV) and voltage drop test module

      ● Built-in single-phase coupling/decoupling network up to 400 V / 32 A

      ● Front panel manual operation, simple and convenient

      ● The start button and stop button have LED indicators to show the test status

      ● With peak voltage and peak current monitoring output port

      ● With fiber optic interface and Ethernet interface for remote control

      ● Can control external three-phase coupling network

      ● Voltage drop test module complies with IEC / EN 61000-4-8 / -11 / -29 standards (DC)

      ● With failure detection function

      Standards compliant:

      ● ECE-R10

      ●EN 300329

      ●EN 300340

      ● EN 300342-1

      ● EN 300386 V1.3.2

      ● EN 301489-1

      ● EN 301489-17

      ● EN 301489-24

      ● EN 301489-7

      ●EN 50121

      ●EN 55024

      ● EN 61000-4-11

      ● EN 61000-4-29

      ● EN 61000-4-4

      ● EN 61000-4-5

      ●EN 61000-4-8

      ● EN 61000-4-9

      ●EN 61000-6-1

      ●EN 61000-6-2

      ● FCC 97-270 (part 68)

      ● IEC 60255-22-5

      ● IEC 61000-4-11

      ● IEC 61000-4-29

      ● IEC 61000-4-4

      ● IEC 61000-4-5

      ● IEC 61000-4-8

      ● IEC 61000-4-9

      ● IEC 61326

      ● IEC 61850-3

      ● ITU-T K.20

      ● ITU-T K.21

      ● ITU-T K.41

      ● ITU-T K.45

      advantage:

      Compact NX5 is capable of full compatibility immunity testing. The host and the device under test are powered independently, so that it can be more flexibly applied to the test of devices under test powered by different voltages.

      The Compact NX5 can be operated manually directly from the front panel and color touchscreen, or remotely via built-in Ethernet, USB or fiber optic interfaces. The failure detection function allows the user to control the ongoing test sequence based on the status of the device under test. The monitoring output port (BNC) helps users to measure and verify signals conveniently. In addition, the Compact NX5 has safety features such as self-locking and indicator lights.

      Compact NX5 can automatically identify the power supply configuration of the connected device under test, and can choose to output waveforms to the specified line through menu settings. Pre-programmed standard test routines are easy to use. Through the quick start test program of Compact NX5, the user can adjust the test parameters online during the test, so as to evaluate the sensitivity threshold of a single device under test.

      Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.

      controlling software:

      Control and report generation software iec.control

      iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.

      iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.

      Other models:

      UCS 500N7 - Ultra-compact anti-interference signal simulator for test voltages up to 7 kV

      UCS 500N7 ultra-compact anti-jamming signal simulator can be used for electrical fast transient/burst, surge, voltage dip, communication surge and ringing wave test, the highest test voltage can reach 7 kV.

      Accessory equipment:

      coupling NX5 - Three-phase coupling/decoupling network for burst and surge testing

      EM TEST provides a series of fully automatic three-phase coupling/decoupling networks for burst and surge testing to expand the testing capabilities for three-phase equipment under test. The nominal current of the network can be up to 200 A.

      variac NX-1-260-16 - Automatic voltage regulator for voltage change testing

      The variac NX-1-260-16 automatic voltage regulator is an alternative test solution for tapped transformers, capable of performing voltage dips, short interruptions and voltage changes in accordance with the requirements of the IEC 61000-4-11 standard. In addition, it can be used for automatic magnetic field testing.

      V 4780 - Fixed tap transformer for voltage dips and short interruption tests

      The V 4780 fixed tap transformer provides the voltage required for voltage dip and short interruption tests as required by the IEC 61000-4-11 Ed.2:2004 standard.

      V 4780S2 - Tapped transformer for voltage dips and short interruption tests

      The V 4780S2 tapped autotransformer supplies the required voltage for voltage dip and short interruption tests according to IEC 61000-4-11 Ed.2:2004. In contrast to the manually operated V 4780, the V 4780S2 can automatically switch taps according to the selected voltage level.

      CNV 504N/508N - Signal/Data Line Coupling/Decoupling Networks for Surge Testing

      CNV 504N / 508N coupling/decoupling network can couple surge pulses to I/O lines, signal/data lines and communication lines, meeting the requirements of IEC 61000-4-5 Ed 3.0 standard.

      appendix:

      MS 100N - Magnetic field coil for power frequency and pulsed magnetic field testing

      MS 100N is a 1 m * 1 m magnetic field coil, which meets the requirements of IEC / EN61000-4-8 and IEC / EN 61000-4-9 standards. The coil moves easily, is height-adjustable, and swivels 360 degrees. When it is necessary to generate low-level power frequency magnetic field strength, the current transformer MC 2630 can be used together. For high-level field strength tests above 100 A/m, MC 26100 current transformers are required.

      CCI - Capacitive Coupling Clamp

      CCI capacitive coupling clamps fully meet the requirements of the IEC 61000-4-4 standard.

      ITP - Immunity Test Probe Assembly

      ITP is a product development diagnostic test tool. It includes a variety of near-field probes that can locate weak points in a system or on a printed circuit board. A burst simulator is used to generate interference signals.

      PVF BKIT 1 - Electrical Fast Transient/Burst Calibration Kit

      According to the requirements of the IEC 61000-4-4 Ed.2 standard, the characteristics of the burst generator are verified by two different loads of 50 ohm and 1,000 ohm. EM TEST provides users with calibration components including these two load resistors and an adapter to verify the output port of the device under test.

      CCI PVKIT 1 - Capacitive Coupled Clamp Calibration Kit

      The IEC/EN 61000-4-4 Ed 3.0 standard published in 2012 recommends calibrating capacitive coupling clamps with a 50 ohm coaxial load. A capacitive coupling clamp (CCI) is connected to the 50 ohm output of the EFT generator. The HFK incorporates a flexible insulating sheet connected to a 50 ohm load resistor to verify the EFT/burst waveform of the capacitive coupling clamp.

     

  • Specific indicators:

    Electrical Fast Transient Bursts
    Burst module EFT complies with EN/IEC 61000-4-4 Ed 3.0 and EN 61000-6-1, -6-2 standards
    Test voltage 200 V - 5,500 V ± 10%;
    100 V - 2,750 V ± 10%, 50ohm load
    Pulse waveform 5 / 50 ns, 50 ohm and 1,000 ohm loads  
    rise time tr 5 ns ± 30% into 50 ohm load;
    5 ns ± 30% into 1,000 ohm load
    Pulse duration td 50 ns ± 30%, 50 ohm load;
    50 ns -15 / +100ns, 1,000 ohm load
    source impedance 50 ohm
    polarity positive, negative
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1° (16 - 500 Hz)
    burst duration td = 0.10 ms - 9,999 ms
    repetition rate tr = 10 ms - 9,999 ms
    Spike frequency f = 1 Hz - 1,000 kHz
    test duration T = 0:01 min - 99:59 min
    T > 99:59 min --> infinite
    output
    CRO trigger Oscilloscope 5 V trigger signal
    direct output Via 50 ohm coaxial connector
    Coupling method L, N, PE and various combinations
    The power supply of the device under test AC 300 V / 400 V, 50/60 Hz
    DC 300 V / 400 V
    Current 16 A / 32 A
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure Conforms to IEC 61000-4-4, Test Level 1 - 4
    Conforms to EN 61000-6-1, -6-2
    Conforms to ECE R-10 Rev5
    user testing program Synchronous burst output
    Random burst output
    Change voltage after T time
    Sweep fixed number of pulses within single burst
    Sweep
    fixed burst duration
    Change polarity after sweep T time
    option
    CCI Capacitive coupling clamp according to IEC 61000-4-4 standard
    PVF 50 100:1 Voltage Divider, 50 ohm
    PVF 1000 500:1 Voltage Divider, 1,000 ohm
    PVF BKIT 1 Burst calibration kit, including PVF50, PVF1000, DUT port adapter and carrying case
    PVF AD 1 Adapter to match the PVF 50 load resistance to the EUT power supply port of the three-phase N-series coupling network
    E.T.C Immunity test probe (generates electric field)
    ITP/H Immunity test probe (generates magnetic field)
    Combined wave/surge
    Surge modules comply with EN/IEC 61000-4-5 Ed 3.0 and EN 61000-6-1, -6-2 standards
    open circuit voltage 160 V - 5,000 V ± 10%
    Front time 1.2 us ± 30%  
    Pulse half peak time 50 us ± 20%
    short circuit current 2,500 A max ± 10%
    Front time 8 us ± 20%
    Pulse half peak time 20 us ± 20%
    polarity positive, negative, alternating
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1°
    repetition rate Up to 1 Hz (1 s - 9,999 s)
    counter 1 - 99,999, optional
    output
    CRO trigger Oscilloscope 5 V trigger signal
    direct output Output to external coupling network via high voltage connector
    Coupling method According to IEC 61000-4-5:
    Line-to-Line, 2 ohm; Line-to-Earth, 12 ohm
    To ANSI/IEEE C62.41:
    Line-to-Line, 2 ohm; Line-to-Earth, 2 ohm  
    The power supply of the device under test AC 300 V / 400 V, 50/60 Hz
    DC 300 V / 400 V
    Current 16 A / 32 A
    Measurement
    CRO voltage monitoring 10 Vp corresponds to 5,000 V
    CRO current monitoring 10 Vp corresponds to 2,500 A
    peak voltage 5,000 V, LCD display
    peak current 2,500 Amps, LCD display
    overcurrent protection When the inrush current exceeds the limit value, interrupt the inrush test
    Differential mode limiter
    Common mode limiter
    DUT current RMS current, range 50 A, < ±5%  
    Device under test overcurrent protection Interrupt test when DUT current exceeds limit
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure According to IEC 61000-4-5, test level 1 - 4
    according to EN 61000-6-1, -6-2
    Manual setting of standard test procedures
    user testing program After N pulses, voltage iteration,
    phase angle step by step iteration,
    phase angle random iteration,
    after N pulses, change the coupling mode,
    after N pulses, change the phase angle
    Pulse Magnetic Field Test Procedure Compliant with IEC 61000-4-9, test levels 100, 300 and 1,000 A/m Test levels are continuously adjustable in the quick start menu
    option
    DCD 5 sr-4-1,
    DCD 5 sr-4-4
    4-wire signal line/data line coupling network
    according to IEC 61000-4-5 standard Ed 3.0
    DCD 5 sr-8-1,
    DCD 5 sr-8-4
    8-wire signal line/data line coupling network
    according to IEC 61000-4-5 standard Ed 3.0
    CNI 508N2 Network Group Coupling/decoupling network and protection network group for unshielded and shielded high-speed communication line (Ethernet line) testing
    SPN 508N1 Surge protection network to reduce surge voltage on auxiliary equipment side to <10 V  
    Voltage dips, short interruptions and voltage changes
    The voltage drop module PFS complies with EN / IEC 61000-4-11, IEC / EN 61000-4-29 standards and EN 61000-6-1, -6-2 standards
    Channel PF1 / PF2 AC voltage: max. 300 V / 400 V
    AC current: max. 16 A / 32 A
    DC voltage: max. 300 V / 400 V
    DC current: max. 16 A / 32 A
    frequency
     
    16 Hz - 500 Hz and DC    
    switch off time > 1 us < 5 us, 100 ohm resistive load (CA PFS-100R)  
    electric shock > 500 A
    Protect Both channels are short-circuit protected
    trigger circuit
    trigger method Automatic, manual, external trigger
    Synchronize 0° - 360°, resolution 1° (16 - 500 Hz)
    repetition rate 10 ms - 9,999 s
    event duration 20 us - 9,999 s
    counter 1 - 99,999, optional
    output
    CRO trigger Oscilloscope 5 V trigger signal
    DUT terminal L, N sum PE
    Measurement
    voltage monitoring Measure the voltage of the device under test, built-in voltage divider
    300 V: 42,5:1, 10 V =425 Vpk,
    400 V: 56.6:1, 10 V =566 Vpk
    current monitoring Measure EUT current
    16 A: 7 A/V; 10 V =70 Apk,
    32 A: 10 A/V; 10 V =100 Apk
    DUT voltage (rms) touch screen display
    DUT current (rms) touch screen display
    test program
    Quick Start Parameters can be adjusted online, simple and fast
    Standard Test Procedure Conforms to IEC 61000-4-11 standard, suitable for AC power supply test
    Conforms to IEC 61000-4-29 standard, suitable for DC power supply test
    Conforms to EN 61000-6-1, -6-2 standard
    Manual setting standard test procedure
    user testing program
    Voltage
    change controlled by an external
    voltage regulator
     
    50 / 60 Hz magnetic field test Complies with IEC / EN 61000-4-8
    with external current transformer MC 2630 for test classes 1, 3, 10 and 30 A / m with external current transformer MC 26100 for test classes 100, 300 and 1,000 A / m
    option
    In 4780 Transformer, fixed tap
    conforming to IEC / EN 61000-4-11 Ed.2
    V 4780S2 Autotransformer with automatic tap change
    according to IEC / EN 61000-4-11 Ed.2
    variac  NX-1-260-16 Automatic voltage regulator (0 - 260 V, 16 A)
    variac  NX-1-260-32 Automatic voltage regulator (0 - 260 V, 32A)
    MFC 1000 Magnetic field coil, 1 mx 1 m Field strengths up to 1000 A/m With trolley Field strengths up to 1000 A/m
    MS 100N Magnetic field coil, 1 mx 1 m Field strengths up to 1000 A/m
    MC 2630 Current transformers for magnetic field testing up to 30 A/m
    MC 26100 Current transformers for magnetic field testing up to 1,000 A/m
    CA PFS Inrush current calibration components comply with IEC 61000-4-11 standard
    CA PFS-100R 100 ohm low inductance load resistors for rise and fall time verification
    general data
    interface
    serial interface 2 USB Type A ports / 1 USB Type B port, fiber optic
    Network Interface Ethernet interface
    analog output External voltage regulator controlled by 0 - 10 V DC voltage analog signal
    Coupled network interface 26-pin SubD interface, control external coupling network
    failure detection Monitor the device under test through failure detection port 1 and failure detection port 2
    external trigger BNC external trigger oscilloscope 5 V trigger signal
    External sync input Differential input
    50 V - 690 V AC
    2 x 4 mm MC safety connectors
    Safety
    safety standard EN/IEC 61010 standard
    safety circuit Control input (24 V DC)
    Warning Light Floating contact (up to 60 V / 2 A)
    general data
    size and weight 16 A model
    19"/3 U, depth 500 mm Approx. 21.8 kg
    32 A model
    19"/6 U, depth 500 mm Approx. 40 kg  
    Supply voltage, frequency 85 V - 264 V ,50 / 60 Hz  
    power
    ,
    about 75W
    fuse 115 V: 2 x 4 A slow blow
    230 V: 2 x 2 A slow blow
    Host comes with accessories
    host power cord Plug type depends on the country of use
    DUT power cord Plug type depends on the country of use
    EUT Adapter Socket type depends on the country of use
      Operation Manual
      Calibration certificate
      iec.control remote control software
    option
    coupling NX5 Three-phase coupling/decoupling network up to 200 A per phase
    Compliant with IEC 61000-4-4 and IEC 61000-4-5
    iec.control Remote control and reporting software including standard test procedures and report generation.
    UOC 5m Fiber Optic, USB-to-Fiber Interface Converter
    Model overview
    compact NX5 bsp-1-300-16 Burst, surge, voltage dip single phase 300 V / 16 A
    compact NX5 bst-1-300-16 Burst, surge, communication surge single phase 300 V / 16 A
    compact NX5 bs-1-300-16 Burst, surge single phase 300 V / 16 A
    compact NX5 bp-1-300-16 Burst, voltage dip single phase 300 V / 16 A
    compact NX5 b-1-300-16 Burst single phase 300 V / 16 A
    compact NX5 s-1-300-16 Surge single phase 300 V / 16 A
    compact NX5 p-1-300-16 Voltage drop single phase 300 V / 16 A
    compact NX5 bsp-1-300-32 Burst, surge, voltage dip single phase 300 V / 32 A
    compact NX5 bs-1-300-32 Burst, surge single phase 300 V / 32 A
    compact NX5 bp-1-300-32 Burst, voltage dip single phase 300 V / 32 A
    compact NX5 sp-1-300-32 Surge, voltage dip single phase 300 V / 32 A
    compact NX5 b-1-300-32 Burst single phase 300 V / 32 A
    compact NX5 s-1-300-32 Surge single phase 300 V / 32 A
    compact NX5 p-1-300-32 Voltage drop single phase 300 V / 32 A
    compact NX5 bsp-1-400-16 Burst, surge, dip 400 V / 16 A
    compact NX5 bsp-1-400-32 Burst, surge, dip 400 V / 32 A
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ