Product
EMC Testing Solution Provider
Compact NX5 Ultra-small anti-jamming signal simulator
Brand:
EM TEST
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Compact NX5 Ultra-small anti-jamming signal simulator
- Commodity ID: 1064482170488901632
- 品牌11: EMTEST
- 行业: 民用
- 描述: Compact NX5 ultra-small electrical fast transient/burst, surge and voltage sag test equipment.
- 品牌: EM TEST
Compact NX5 Ultra-compact EFT/Burst, Surge and Dip test equipment.
Compact NX5 ultra-small simulator is a multi-functional test equipment that can meet various requirements of international standards (basic standards and general standards) and product series standards for transient, pulse, surge and voltage drop tests. The Compact NX5 is equipped with an easy-to-use color touch screen, built-in single-phase coupling/decoupling network, and can perform three-phase EUT testing with an automatically controlled external coupling network (up to 200 A per phase), making it a The most economical solution for product development testing and fully compliant immunity testing for EU CE certification.
maximum
-
main feature:
● The lightest combined simulator with a 7” touch screen
● Built-in burst test module (5.5 kV), surge test module (5.0 kV) and voltage drop test module
● Built-in single-phase coupling/decoupling network up to 400 V / 32 A
● Front panel manual operation, simple and convenient
● The start button and stop button have LED indicators to show the test status
● With peak voltage and peak current monitoring output port
● With fiber optic interface and Ethernet interface for remote control
● Can control external three-phase coupling network
● Voltage drop test module complies with IEC / EN 61000-4-8 / -11 / -29 standards (DC)
● With failure detection function
Standards compliant:
● ECE-R10
●EN 300329
●EN 300340
● EN 300342-1
● EN 300386 V1.3.2
● EN 301489-1
● EN 301489-17
● EN 301489-24
● EN 301489-7
●EN 50121
●EN 55024
● EN 61000-4-11
● EN 61000-4-29
● EN 61000-4-4
● EN 61000-4-5
●EN 61000-4-8
● EN 61000-4-9
●EN 61000-6-1
●EN 61000-6-2
● FCC 97-270 (part 68)
● IEC 60255-22-5
● IEC 61000-4-11
● IEC 61000-4-29
● IEC 61000-4-4
● IEC 61000-4-5
● IEC 61000-4-8
● IEC 61000-4-9
● IEC 61326
● IEC 61850-3
● ITU-T K.20
● ITU-T K.21
● ITU-T K.41
● ITU-T K.45
advantage:
Compact NX5 is capable of full compatibility immunity testing. The host and the device under test are powered independently, so that it can be more flexibly applied to the test of devices under test powered by different voltages.
The Compact NX5 can be operated manually directly from the front panel and color touchscreen, or remotely via built-in Ethernet, USB or fiber optic interfaces. The failure detection function allows the user to control the ongoing test sequence based on the status of the device under test. The monitoring output port (BNC) helps users to measure and verify signals conveniently. In addition, the Compact NX5 has safety features such as self-locking and indicator lights.
Compact NX5 can automatically identify the power supply configuration of the connected device under test, and can choose to output waveforms to the specified line through menu settings. Pre-programmed standard test routines are easy to use. Through the quick start test program of Compact NX5, the user can adjust the test parameters online during the test, so as to evaluate the sensitivity threshold of a single device under test.
Through the front panel menu and function keys, users can quickly and accurately edit the test program. The control cursor is used to quickly control all test parameters of the programmed test program, which makes the test process very simple and ensures that each test step can be carried out correctly.
controlling software:
Control and report generation software iec.control
iec.control is a very user-friendly control software. It is easy to use, has a clear user interface structure and strong flexibility. Various operating functions and EM TEST standard information library allow users to easily complete custom test procedures. It can automatically identify the connected EM TEST test equipment and perform automatic configuration. Its powerful reporting function can help users generate test reports that meet international requirements.
iec.control supports Windows 7, Windows 8 (64Bit) and Windows 10 operating systems. Remote control is done via USB or GPIB interface. iec.control is compatible with various GPIB cards of National Instruments.
Other models:
UCS 500N7 - Ultra-compact anti-interference signal simulator for test voltages up to 7 kV
UCS 500N7 ultra-compact anti-jamming signal simulator can be used for electrical fast transient/burst, surge, voltage dip, communication surge and ringing wave test, the highest test voltage can reach 7 kV.
Accessory equipment:
coupling NX5 - Three-phase coupling/decoupling network for burst and surge testing
EM TEST provides a series of fully automatic three-phase coupling/decoupling networks for burst and surge testing to expand the testing capabilities for three-phase equipment under test. The nominal current of the network can be up to 200 A.
variac NX-1-260-16 - Automatic voltage regulator for voltage change testing
The variac NX-1-260-16 automatic voltage regulator is an alternative test solution for tapped transformers, capable of performing voltage dips, short interruptions and voltage changes in accordance with the requirements of the IEC 61000-4-11 standard. In addition, it can be used for automatic magnetic field testing.
V 4780 - Fixed tap transformer for voltage dips and short interruption tests
The V 4780 fixed tap transformer provides the voltage required for voltage dip and short interruption tests as required by the IEC 61000-4-11 Ed.2:2004 standard.
V 4780S2 - Tapped transformer for voltage dips and short interruption tests
The V 4780S2 tapped autotransformer supplies the required voltage for voltage dip and short interruption tests according to IEC 61000-4-11 Ed.2:2004. In contrast to the manually operated V 4780, the V 4780S2 can automatically switch taps according to the selected voltage level.
CNV 504N/508N - Signal/Data Line Coupling/Decoupling Networks for Surge Testing
CNV 504N / 508N coupling/decoupling network can couple surge pulses to I/O lines, signal/data lines and communication lines, meeting the requirements of IEC 61000-4-5 Ed 3.0 standard.
appendix:
MS 100N - Magnetic field coil for power frequency and pulsed magnetic field testing
MS 100N is a 1 m * 1 m magnetic field coil, which meets the requirements of IEC / EN61000-4-8 and IEC / EN 61000-4-9 standards. The coil moves easily, is height-adjustable, and swivels 360 degrees. When it is necessary to generate low-level power frequency magnetic field strength, the current transformer MC 2630 can be used together. For high-level field strength tests above 100 A/m, MC 26100 current transformers are required.
CCI - Capacitive Coupling Clamp
CCI capacitive coupling clamps fully meet the requirements of the IEC 61000-4-4 standard.
ITP - Immunity Test Probe Assembly
ITP is a product development diagnostic test tool. It includes a variety of near-field probes that can locate weak points in a system or on a printed circuit board. A burst simulator is used to generate interference signals.
PVF BKIT 1 - Electrical Fast Transient/Burst Calibration Kit
According to the requirements of the IEC 61000-4-4 Ed.2 standard, the characteristics of the burst generator are verified by two different loads of 50 ohm and 1,000 ohm. EM TEST provides users with calibration components including these two load resistors and an adapter to verify the output port of the device under test.
CCI PVKIT 1 - Capacitive Coupled Clamp Calibration Kit
The IEC/EN 61000-4-4 Ed 3.0 standard published in 2012 recommends calibrating capacitive coupling clamps with a 50 ohm coaxial load. A capacitive coupling clamp (CCI) is connected to the 50 ohm output of the EFT generator. The HFK incorporates a flexible insulating sheet connected to a 50 ohm load resistor to verify the EFT/burst waveform of the capacitive coupling clamp.
-
Specific indicators:
Electrical Fast Transient Bursts Burst module EFT complies with EN/IEC 61000-4-4 Ed 3.0 and EN 61000-6-1, -6-2 standards Test voltage 200 V - 5,500 V ± 10%;
100 V - 2,750 V ± 10%, 50ohm loadPulse waveform 5 / 50 ns, 50 ohm and 1,000 ohm loads rise time tr 5 ns ± 30% into 50 ohm load;
5 ns ± 30% into 1,000 ohm loadPulse duration td 50 ns ± 30%, 50 ohm load;
50 ns -15 / +100ns, 1,000 ohm loadsource impedance 50 ohm polarity positive, negative trigger circuit trigger method Automatic, manual, external trigger Synchronize 0° - 360°, resolution 1° (16 - 500 Hz) burst duration td = 0.10 ms - 9,999 ms repetition rate tr = 10 ms - 9,999 ms Spike frequency f = 1 Hz - 1,000 kHz test duration T = 0:01 min - 99:59 min
T > 99:59 min --> infiniteoutput CRO trigger Oscilloscope 5 V trigger signal direct output Via 50 ohm coaxial connector Coupling method L, N, PE and various combinations The power supply of the device under test AC 300 V / 400 V, 50/60 Hz
DC 300 V / 400 V
Current 16 A / 32 Atest program Quick Start Parameters can be adjusted online, simple and fast Standard Test Procedure Conforms to IEC 61000-4-4, Test Level 1 - 4
Conforms to EN 61000-6-1, -6-2
Conforms to ECE R-10 Rev5user testing program Synchronous burst output
Random burst output
Change voltage after T time
Sweep fixed number of pulses within single burst
Sweep
fixed burst duration
Change polarity after sweep T timeoption CCI Capacitive coupling clamp according to IEC 61000-4-4 standard PVF 50 100:1 Voltage Divider, 50 ohm PVF 1000 500:1 Voltage Divider, 1,000 ohm PVF BKIT 1 Burst calibration kit, including PVF50, PVF1000, DUT port adapter and carrying case PVF AD 1 Adapter to match the PVF 50 load resistance to the EUT power supply port of the three-phase N-series coupling network E.T.C Immunity test probe (generates electric field) ITP/H Immunity test probe (generates magnetic field) Combined wave/surge Surge modules comply with EN/IEC 61000-4-5 Ed 3.0 and EN 61000-6-1, -6-2 standards open circuit voltage 160 V - 5,000 V ± 10% Front time 1.2 us ± 30% Pulse half peak time 50 us ± 20% short circuit current 2,500 A max ± 10% Front time 8 us ± 20% Pulse half peak time 20 us ± 20% polarity positive, negative, alternating trigger circuit trigger method Automatic, manual, external trigger Synchronize 0° - 360°, resolution 1° repetition rate Up to 1 Hz (1 s - 9,999 s) counter 1 - 99,999, optional output CRO trigger Oscilloscope 5 V trigger signal direct output Output to external coupling network via high voltage connector Coupling method According to IEC 61000-4-5:
Line-to-Line, 2 ohm; Line-to-Earth, 12 ohm
To ANSI/IEEE C62.41:
Line-to-Line, 2 ohm; Line-to-Earth, 2 ohmThe power supply of the device under test AC 300 V / 400 V, 50/60 Hz
DC 300 V / 400 V
Current 16 A / 32 AMeasurement CRO voltage monitoring 10 Vp corresponds to 5,000 V CRO current monitoring 10 Vp corresponds to 2,500 A peak voltage 5,000 V, LCD display peak current 2,500 Amps, LCD display overcurrent protection When the inrush current exceeds the limit value, interrupt the inrush test
Differential mode limiter
Common mode limiterDUT current RMS current, range 50 A, < ±5% Device under test overcurrent protection Interrupt test when DUT current exceeds limit test program Quick Start Parameters can be adjusted online, simple and fast Standard Test Procedure According to IEC 61000-4-5, test level 1 - 4
according to EN 61000-6-1, -6-2
Manual setting of standard test proceduresuser testing program After N pulses, voltage iteration,
phase angle step by step iteration,
phase angle random iteration,
after N pulses, change the coupling mode,
after N pulses, change the phase anglePulse Magnetic Field Test Procedure Compliant with IEC 61000-4-9, test levels 100, 300 and 1,000 A/m Test levels are continuously adjustable in the quick start menu option DCD 5 sr-4-1,
DCD 5 sr-4-44-wire signal line/data line coupling network
according to IEC 61000-4-5 standard Ed 3.0DCD 5 sr-8-1,
DCD 5 sr-8-48-wire signal line/data line coupling network
according to IEC 61000-4-5 standard Ed 3.0CNI 508N2 Network Group Coupling/decoupling network and protection network group for unshielded and shielded high-speed communication line (Ethernet line) testing SPN 508N1 Surge protection network to reduce surge voltage on auxiliary equipment side to <10 V Voltage dips, short interruptions and voltage changes The voltage drop module PFS complies with EN / IEC 61000-4-11, IEC / EN 61000-4-29 standards and EN 61000-6-1, -6-2 standards Channel PF1 / PF2 AC voltage: max. 300 V / 400 V
AC current: max. 16 A / 32 A
DC voltage: max. 300 V / 400 V
DC current: max. 16 A / 32 Afrequency
16 Hz - 500 Hz and DC switch off time > 1 us < 5 us, 100 ohm resistive load (CA PFS-100R) electric shock > 500 A Protect Both channels are short-circuit protected trigger circuit trigger method Automatic, manual, external trigger Synchronize 0° - 360°, resolution 1° (16 - 500 Hz) repetition rate 10 ms - 9,999 s event duration 20 us - 9,999 s counter 1 - 99,999, optional output CRO trigger Oscilloscope 5 V trigger signal DUT terminal L, N sum PE Measurement voltage monitoring Measure the voltage of the device under test, built-in voltage divider
300 V: 42,5:1, 10 V =425 Vpk,
400 V: 56.6:1, 10 V =566 Vpkcurrent monitoring Measure EUT current
16 A: 7 A/V; 10 V =70 Apk,
32 A: 10 A/V; 10 V =100 ApkDUT voltage (rms) touch screen display DUT current (rms) touch screen display test program Quick Start Parameters can be adjusted online, simple and fast Standard Test Procedure Conforms to IEC 61000-4-11 standard, suitable for AC power supply test
Conforms to IEC 61000-4-29 standard, suitable for DC power supply test
Conforms to EN 61000-6-1, -6-2 standard
Manual setting standard test procedureuser testing program
Voltage
change controlled by an external
voltage regulator
50 / 60 Hz magnetic field test Complies with IEC / EN 61000-4-8
with external current transformer MC 2630 for test classes 1, 3, 10 and 30 A / m with external current transformer MC 26100 for test classes 100, 300 and 1,000 A / moption In 4780 Transformer, fixed tap
conforming to IEC / EN 61000-4-11 Ed.2V 4780S2 Autotransformer with automatic tap change
according to IEC / EN 61000-4-11 Ed.2variac NX-1-260-16 Automatic voltage regulator (0 - 260 V, 16 A) variac NX-1-260-32 Automatic voltage regulator (0 - 260 V, 32A) MFC 1000 Magnetic field coil, 1 mx 1 m Field strengths up to 1000 A/m With trolley Field strengths up to 1000 A/m MS 100N Magnetic field coil, 1 mx 1 m Field strengths up to 1000 A/m MC 2630 Current transformers for magnetic field testing up to 30 A/m MC 26100 Current transformers for magnetic field testing up to 1,000 A/m CA PFS Inrush current calibration components comply with IEC 61000-4-11 standard CA PFS-100R 100 ohm low inductance load resistors for rise and fall time verification general data interface serial interface 2 USB Type A ports / 1 USB Type B port, fiber optic Network Interface Ethernet interface analog output External voltage regulator controlled by 0 - 10 V DC voltage analog signal Coupled network interface 26-pin SubD interface, control external coupling network failure detection Monitor the device under test through failure detection port 1 and failure detection port 2 external trigger BNC external trigger oscilloscope 5 V trigger signal External sync input Differential input
50 V - 690 V AC
2 x 4 mm MC safety connectorsSafety safety standard EN/IEC 61010 standard safety circuit Control input (24 V DC) Warning Light Floating contact (up to 60 V / 2 A) general data size and weight 16 A model
19"/3 U, depth 500 mm Approx. 21.8 kg
32 A model
19"/6 U, depth 500 mm Approx. 40 kgSupply voltage, frequency 85 V - 264 V ,50 / 60 Hz power
,about 75W fuse 115 V: 2 x 4 A slow blow
230 V: 2 x 2 A slow blowHost comes with accessories host power cord Plug type depends on the country of use DUT power cord Plug type depends on the country of use EUT Adapter Socket type depends on the country of use Operation Manual Calibration certificate iec.control remote control software option coupling NX5 Three-phase coupling/decoupling network up to 200 A per phase
Compliant with IEC 61000-4-4 and IEC 61000-4-5iec.control Remote control and reporting software including standard test procedures and report generation. UOC 5m Fiber Optic, USB-to-Fiber Interface Converter Model overview compact NX5 bsp-1-300-16 Burst, surge, voltage dip single phase 300 V / 16 A compact NX5 bst-1-300-16 Burst, surge, communication surge single phase 300 V / 16 A compact NX5 bs-1-300-16 Burst, surge single phase 300 V / 16 A compact NX5 bp-1-300-16 Burst, voltage dip single phase 300 V / 16 A compact NX5 b-1-300-16 Burst single phase 300 V / 16 A compact NX5 s-1-300-16 Surge single phase 300 V / 16 A compact NX5 p-1-300-16 Voltage drop single phase 300 V / 16 A compact NX5 bsp-1-300-32 Burst, surge, voltage dip single phase 300 V / 32 A compact NX5 bs-1-300-32 Burst, surge single phase 300 V / 32 A compact NX5 bp-1-300-32 Burst, voltage dip single phase 300 V / 32 A compact NX5 sp-1-300-32 Surge, voltage dip single phase 300 V / 32 A compact NX5 b-1-300-32 Burst single phase 300 V / 32 A compact NX5 s-1-300-32 Surge single phase 300 V / 32 A compact NX5 p-1-300-32 Voltage drop single phase 300 V / 32 A compact NX5 bsp-1-400-16 Burst, surge, dip 400 V / 16 A compact NX5 bsp-1-400-32 Burst, surge, dip 400 V / 32 A