Wisdom

Product


EMC Testing Solution Provider


CIT-100 Conducted Immunity Integrated Machine

Brand:

FRANKONIA

CIT-100 Conducted Immunity Integrated Machine
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: CIT-100 Conducted Immunity Integrated Machine
    • Commodity ID: 1064816159409983488
    • 品牌11: FRANKONIA
    • 描述: The CIT-100 is a complete conducted immunity and high current injection immunity test system that fully complies with IEC/EN 61000-4-6, ISO 11452-4, MIL-STD 461, CS114 and similar standards.
    • 品牌: FRANKONIA

      The CIT-100 is a complete conducted immunity and high current injection immunity test system that fully complies with IEC/EN 61000-4-6, ISO 11452-4, MIL-STD 461, CS114 and similar standards. It contains a 4kHz - 1.2 GHz signal source, a 4kHz - 400 MHz, 25 / 75 W amplifier, 4kHz to 1.2 GHz triple-channel power meter to monitor forward and reverse power, built-in directional coupler, and test software.

  • RFSignal source

    Two-channel output

    2 x SMA

    Frequency range

    4 kHz to 1.2 GHz

    Frequency resolution

    1 Hz

    Output grade range

    0 to -63 dBm

    Output resolution

    0.1 dB

    noise

    < 30 dBc

    Amplitude built-in

    0 - 100%, resolution 1%

    Amplitude external

    0-100%, max. Amplitude 1V=100%,

    BNC jack

    Pulse modulation internal

    5-95%, resolution 1%

    Pulse modulation external

    DC... 1MHz, 3,3/5V CMOS/TTL, BNC jack

    LFSignal source

    interface

    BNC

    Frequency range

    1Hz~100kHz

    Frequency resolution

    0.1Hz

    waveform

    Sine wave/square wave/triangle wave

    Amplitude

    0...1 V

    RFVoltmeter 1 (for calibration)

    interface

    BNC

    Frequency range

    4 kHz to 1.2 GHz

    Range

    -40 to +30 dBm

    RFVoltmeter 2&3 (forward reverse power)

    interface

    2 x SMA

    Frequency range

    4 kHz to 1.2 GHz

    Range

    -40 to +33 dBmup to 40dBm

    EUT-Monitorport

    Input voltage

    0-10 V

    resolution

    2.5 mV

    Input impedance

    100 k

    EUT-failed

    Input voltage

    3.3/5V CMOS/TTL level

    Detection method

    Condition detection or critical control

    Power amplifier

     

     

     

    Model

    CIT-100/25

    CIT-100/75MIL

    CIT-100/75

    Frequency range

    100kHz-250MHz

    (4) 1 0kHz-250 (400) MHz

    100kHz-400MHz

    power

    25W

    75W

    75W

    1dBCompression point power

    20W

    50W

    50W

    gain

    46dB

    51dB

    51dB

    Flatness

    ± 1.5 dB maximum

    Rated input power

    1 mW / 0 dBm

    Input and output impedance

    50 Oh

    VSWR

    1.5:1 max

    harmonic wave

    <- 20 dBc @ 20 W

    <- 20 dBc @ 50 W

    <- 20 dBc @ 50 W

    noise

    type. 5 dB

    type. 7 dB

    type. 7 dB