EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
Line Wave Tube Amplifier TWAL 0818_8GHz-18GHz
Brand:
BONN
- Product Description
- Main features
- Technical parameters
-
- Commodity name: Line Wave Tube Amplifier TWAL 0818_8GHz-18GHz
- Commodity ID: 1064815389386100736
- 品牌11: BONN
- 描述: TWAL 0818_8GHz-18GHz line wave tube amplifier
- 品牌: BONN
Model
Frequency range
Output power(Pp min/ duty cycle) W/%
Gain (min/typ)dB
Harmonics
2nd / 3rd dBc
TWAL 0818-20
8GHz-18GHz
20/30
43 / 53 ±10
12 / 20
TWAL 0818-50/35
8GHz-18GHz
8GHz-15GHz
50 / 60
47 / 55 ±7.5
5 / 20
15GHz-18GHz
35 / 50
43 / 51 ±7.5
5 / 20
TWAL 0818-250
8GHz-18GHz
250/300
54 / 62 ±7.5
8 / 20
TWAL 0818-250E
8GHz-18GHz
250/300
54 / 62 ±7.5
7 / 15
TWAL 0818-320
8GHz-18GHz
320/350
55 / 63 ±7.5
6 / 18
TWAL 0818-500
8GHz-18GHz
500/550
57 / 65 ±7.5
7/ 20
TWAL 0818-500E
8GHz-18GHz
500/550
57 / 65 ±7.5
7/ 20
TWAL 0818-1000
8GHz-18GHz
1000/1100
60 / 65 ±5
10 / 20
TWAL 0818-1000E
8GHz-18GHz
1000/1100
60 / 65 ±5
10 / 20
TWAL 0818-2000
8GHz-18GHz
2000/2200
63 / 70 ±7.5
10 / 20
Model
Frequency range
Cable power
VA
Dimension(H, D)19"System
1 HU = 44.45 mm
Weight
kg
TWAL 0818-20
8GHz-18GHz
400
3 HU, 630 mm
21
TWAL 0818-50/35
8GHz-18GHz
400
3 HU, 630 mm
20
TWAL 0818-250
8GHz-18GHz
1500
3 HU, 630 mm
34
TWAL 0818-250E
8GHz-18GHz
2000
4 HU, 630 mm
32
TWAL 0818-320
8GHz-18GHz
1600
3 HU, 630 mm
34
TWAL 0818-500
8GHz-18GHz
4000
15 HU, 700 mm
115
TWAL 0818-500E
8GHz-18GHz
3000
8 HU, 630 mm
55
TWAL 0818-1000
8GHz-18GHz
8000
24 HU, 800 mm
225
TWAL 0818-1000E
8GHz-18GHz
8000
24 HU, 800 mm
225
TWAL 0818-2000
8GHz-18GHz
16000
41 HU, 800 mm
490
-
TWAL 0818_8GHz-18GHz line wave tube amplifier
-
RF input interface:
1-18 GHz N −f, standard on rear panel;
18-40 GHz 2.92 mm-f, standard on rear panel
RF output interface (0-1kW):
1-18 GHz N-f,
6-18 GHz WRD 650,
8-18 GHz WRD 750,
18-26.5 GHz WR 42,
26.5-40 GHz WR 28
RF output interface (above 1kW):
1-8 GHz 7-16-f,
8-18GHz WRD 750
power input:
200 ... 240 V AC 47 ... 63 Hz
Operating schedule:
Via status display
Ambient temperature:
0 ... +45 °C
storage temperature:
-20 ... +85 °C
Relative humidity:
up to 95% ( no condensation)
Operating Altitude:
Up to 2000 m
Vibration and Shock
normal laboratory environment
cool down:
Internal fan forced air cooling, air intake at the front, exhaust at the rear