Wisdom

Product


EMC Testing Solution Provider


P500 set RF power injection probe set

Brand:

LANGER

P500 set RF power injection probe set
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: P500 set RF power injection probe set
    • Commodity ID: 1064798772149243904
    • 品牌11: LANGER
    • 描述: The P500 probe set is used for conducted immunity measurements according to IEC 62132-4.
    • 品牌: LANGER

            The P500 probe set is used for conducted immunity measurements according to IEC 62132-4. Knowing its noise immunity performance data can enable the optimization of integrated circuits. The DPI coupling network (P501, P502, P503) allows coupling of radio frequency interference signals of different frequency ranges and different input voltages.

  • The P500 set includes the following accessories:

     

  • 1. P501, DPI coupling network

    The capacity of the coupling capacitor

    3 µF

    Voltmeter (without preamp)

    Frequency Range

    16 kHz3 GHz

    Measurement output

    50Ω, SMB

    transfer coefficient

    -40 dB

    Ammeter (with preamp)

    1 dB compression point

    120 dBµV

    Frequency Range

    2 MHz3 GHz

    IP3

    134 dBµV

    Current correction factor R (2 MHz - 40 MHz) [dBΩ]

    characteristic curve

    Typical Calibration Curve R (40 MHz - 3 GHz)

    0 dBΩ ( = 1 V/A)

    Measurement output

    50Ω, SMB

    Noise Figure

    4.5 dB

    Current lags behind voltage

    135 ps

    voltage

    12 V / DC

    Maximum Forward Power

    30W

    Maximum RF Input Voltage

    50 Veff

    Maximum RF Input Current

    1 A

    input interface

    50Ω, SMA

    2. P502, DPI coupling network

    The capacity of the coupling capacitor

    3 µF

    Voltmeter (with preamp)

    1 dB compression point

    120 dBµV

    Frequency Range

    16 kHz3 GHz

    IP3

    134 dBµV

    Measurement output

    50Ω, SMB

    Noise Figure

    4.5 dB

    transfer coefficient

    0 dB

    Ammeter (with preamp)

    1 dB compression point

    120 dBµV

    Frequency Range

    2 MHz3 GHz

    IP3

    134 dBµV

    Current correction factor R (2 MHz - 40 MHz) [dBΩ]

    Characteristic parameters

    Typical Calibration Curve R (40 MHz - 3 GHz)

    0 dBΩ ( = 1 V/A)

    Measurement output

    50Ω, SMB

    Noise Figure

    4.5 dB

    Current lags behind voltage

    135 ps

    voltage

    12 V / DC

    Maximum Forward Power

    30W

    Maximum RF Input Voltage

    1 Veff

    Maximum RF Input Current

    1 A

    input interface

    50Ω, SMA

    3. P503, DPI coupling network

    The capacity of the coupling capacitor

    3 µF

    Voltmeter (without preamp)

    Frequency Range

    16 kHz3 GHz

    Measurement output

    50 Ohms, SMB

    transfer coefficient

    -40 dB

    Ammeter (with preamp)

    1 dB compression point

    120 dBµV

    Frequency Range

    200 kHz1 GHz

    IP3

    134 dBµV

    Typical Calibration Curve R(2 MHz - 1 GHz)

    0 dBΩ ( = 1 V/A)

    Current correction factor R (200 kHz - 2 MHz) [dBΩ]

    Characteristic parameters

    Measurement output

    50 Ohms, SMB

    Noise Figure

    4.5 dB

    Current lags behind voltage

    240 ps

    voltage

    12 V / DC

    Maximum Forward Power

    30W

    Maximum RF Input Voltage

    50 Veff

    Maximum RF Input Current

    1 A

    input interface

    50Ω, SMA

Contact

Get Quote

Download

全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Century Wisdom will arrange professional staff to serve you

Operation
Submit RFQ