P501 set RF Power Injection Probe

Brand:

LANGER

P501 set RF Power Injection Probe
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: P501 set RF Power Injection Probe
    • Commodity ID: 1064798967360540672
    • 品牌11: LANGER
    • 描述: The P501 probe set is used for conducted immunity measurements according to IEC 62132-4.
    • 品牌: LANGER

           The P501 probe set is used for conducted immunity measurements according to IEC 62132-4. Knowing its noise immunity performance data enables integrated circuit optimization.

  • The P501 set includes the following accessories:

     

  • The capacity of the coupling capacitor

    3 µF

    Voltmeter (without preamp)

    Frequency Range

    16 kHz3 GHz

    Measurement output

    50Ω, SMB

    transfer coefficient

    -40 dB

    Ammeter (with preamp)

    1 dB compression point

    120 dBµV

    Frequency Range

    2 MHz3 GHz

    IP3

    134 dBµV

    Current correction factor R (2 MHz - 40 MHz) [dBΩ]

    characteristic curve

    Typical Calibration Curve R (40 MHz - 3 GHz)

    0 dBΩ ( = 1 V/A)

    Measurement output

    50Ω, SMB

    Noise Figure

    4.5 dB

    Current lags behind voltage

    135 ps

    voltage

    12 V / DC

    Maximum Forward Power

    30W

    Maximum RF Input Voltage

    50 Veff

    Maximum RF Input Current

    1 A

    input interface

    50Ω, SMA

Contact